Sampling point
recommendations
The suction hose must always be submerged in liquid at the sampling point.
Suitable measures for this are:
Weight the end of the hose using a short length of V2A tubing or fixing the
hose to the channel (tank) wall using a hose saddle or the submersion
armature (can be ordered as an accessory).
Submersion armature: PVC. is pivoted to move in all directions. Order No. 50038168
A suction filter can be used in applications
where large solids particles are not required
in the sample.
A= Filter
B= Connector
C= Jubilee clip
Filter order No. 50038327
Recommendation:
Never submerge the hose against
the flow direction !
If possible sample with the flow.
Sampler with flow through
armature
Flow rate min.200l/h max.1500l/h
Vacuum sampling from A
Inlet B 3/4"
Outlet C 11/4"
Attention: It must be guaranteed
that liquid flow at the outlet C is
free to atmosphere. Should the
system come under pressure the
water head at A will rise and can
lead to flooding the sampler.
We accept no liability for damage caused by ignoring this information !
asp-station d 2
Mechanical installation