Service Information

GENERAL INFORMATION

Your 

SWIMCROSS

 exercise system has been designed to provide 

years of trouble-free use. As with any appliance, problems may 

occasionally occur that require the expertise of a qualified service 

person. Though such simple repairs as resetting a GFCI switch or 

breaker, or resetting a high limit thermostat may not require a service 

call, they may indicate that a more serious condition exists. These 

conditions may require an experienced service person. Before calling for 

service, please refer to the Troubleshooting Guide. Always retain your 

original sales receipt for future reference.

GFCI AND HIGH LIMIT THERMOSTAT

If your exercise system fails to operate at any time, first check the 

power supply to the exercise system.
Check each of the GFCI breakers in the subpanel. If a GFCI has tripped, 

reset it. If it will not reset, this may be an indication of a ground fault 

(short circuit) within the electrical components. Contact an Authorized 

Service Technician for a complete diagnosis.
If upon checking the GFCI’s you find that they have not tripped, check 

the house breaker panel and ensure the main breaker for the electrical 

circuit supplying the exercise system has not tripped. If it has, this is an 

indication that the circuit was either overloaded or a ground fault exists 

between the breaker panel and the exercise system receptacle or 

subpanel. Contact a qualified electrician.
If upon checking the main house breaker and exercise system 

GFCI’s you find no failures, check the high limit thermostat. To check 

it, simply turn off power to the exercise system for 30 seconds. This 

will automatically reset the high limit thermostat if it has tripped. If the 

exercise system energizes once you turn the power back on, this 

indicates reduced water flow through the heating system. Tripping of 

the high limit thermostat is normally a result of one or a combination 

of these problems. 1) clogged filter cartridge(s), 2) blockage within the 

system plumbing, 3) a non-functioning heater circulation pump, 4) power 

was not disconnected from the exercise system before it was drained, 

5) an air lock in the plumbing lines. (The Power Indicator on the front of 

the exercise system’s control panel will also be blinking if the high limit 

thermostat circuit has tripped.)
If the exercise system does not function after tripping and resetting 

the GFCI’s or resetting the high limit thermostat, then the problem 

should be referred to an Authorized Service Technician. Refer to the 

Troubleshooting Guide for additional service information.

MISCELLANEOUS SERVICE 

INFORMATION

The control and high-limit thermostats are equipped with electronic 

sensors that are connected to the exercise system’s plumbing. Never 

cut or kink the wires that connect the sensors to the thermostats within 

the control box.
The jet pump is equipped with a thermal overload cutoff switch that is 

designed to protect the pump from overheating. If the pump shuts itself 

off in an older exercise system, it could indicate failure of the pump 

motor bearings. If the pump shuts itself off in a new exercise system, it 

is usually the result of one or a combination of the following factors:
•  Thermal overload: Although mass-produced, not all thermal overload 

cutoffs are exactly the same. Some are more sensitive than others and 

will shut the pump off at lower temperatures.

•  High temperature: All 

SWIMCROSS

 exercise system models are 

equipped with a jet pump shroud that vents the heat generated by the 

pump motor to the outside of the equipment compartment, and back 

into the exercise system water. If the vent is blocked by masonry, 

grass or debris, overheating of the jet pump may occur. Once the pump 

motor has cooled sufficiently and any blockage has been removed from 

the vent opening, the jet pump can be restarted.

•  Friction: Sometimes the moving parts of a new pump are tight enough 

to cause heat build-up due to friction. After a normal break-in period, 

the pump will run cooler.

•  Improper wiring: If the exercise system is connected with an extension 

cord, and/or the house wiring is undersized, the pump may starve 

for voltage and therefore may draw more amperage and generate 

excessive heat.

•  If the pump is shutting down due to excessive heat, make sure the 

equipment compartment has adequate ventilation. The air gap at the 

bottom must not be blocked. Should your jet pump continue to shut off 

after short periods of use, contact a qualified service technician.

ACTS INVALIDATING WARRANTY

The limited warranty is void if the 

SWIMCROSS

 exercise system has 

been improperly installed, subjected to alteration, misuse, or abuse, or 

if any repairs on the exercise system are attempted by anyone other 

than an authorized representative of Watkins Wellness. Alteration shall 

include any component or plumbing change, electrical conversion, or the 

addition of any non-approved sanitation or water purification device or 

heating system which contributes to component or unit failure or unsafe 

operating system. Misuse and abuse shall include any operation of 

the exercise system other than in accordance with Watkins Wellness 

printed instructions, or use of the exercise system in an application 

for which it is not designed; specifically: use of the exercise system 

in a non-residential application; damage caused by operation* of the 

exercise system at water temperatures outside the range of 2°C and 

49°C (35°F and 120°F); damage caused by a dirty, clogged or calcified 

filter cartridge; damage to the exercise system surface caused by 

the use of tri-chloro chlorine, BCDMH, misuse of chemical tablets in 

a floater, acid, or any other exercise system chemicals or exercise 

system surface cleaners which are not recommended by Watkins 

Wellness; damage caused by allowing undissolved exercise system 

sanitizing chemicals to lie on the exercise system surface (no exercise 

system surface material can withstand this kind of abuse); damage to 

components or exercise system surface caused by improper water 

chemistry maintenance; and damage to the exercise system surface 

caused by leaving the exercise system uncovered while empty of water 

and in direct exposure to sunlight (this may cause solar heating distress 

in warm weather regions). These are considered abuses and may 

invalidate this warranty.
*Operation of the exercise system does not mean “use” of the exercise 

system! Watkins Wellness does not recommend using the exercise 

system if the water temperature is above or below the exercise 

system’s control panel temperature range.

Service Information

Содержание X2000 SwimCross

Страница 1: ...X2000 SwimCross System OWNER S MANUAL 50HZ by Endless Pools...

Страница 2: ...________________ DATE INSTALLED ______________________________________ DEALER _____________________________________________ ADDRESS ____________________________________________ TELEPHONE _____________...

Страница 3: ...ALL OFF MEMORY ON 16 SPA SIDE CONTROL PANEL 17 SETTINGS 17 INVERT SCREEN 19 TEMPERATURE CONTROL 19 JETS CONTROL 19 LIGHT CONTROL 20 FILTER CYCLES 20 POLLING 20 ALL OFF MEMORY ON 20 WI FI IN TOUCH OPT...

Страница 4: ...qualified service personnel Do not attach an external antennae to an exercise system audio system unless installed by a licensed electrician in accordance with your National Electric Code WARNING To...

Страница 5: ...high blood pressure circulatory system problems or diabetes should consult a physician before using exercise system UNCLEAN WATER Keep the water clean and sanitized with correct chemical care The reco...

Страница 6: ...of the control box by the exercise system owner will void the warranty If you have an operational problem carefully go through the steps outlined in the Troubleshooting section If you are not able to...

Страница 7: ...to a source of water Do not use the exercise system above a finished living area due to the risk of water damage The exercise system is not designed for in floor installation However it is compatible...

Страница 8: ...When a small reach is needed for the final placement of your system a boom truck is ideal Atelehandler vehicle can off load traverse property and place your system in a more challenging situation or...

Страница 9: ...concrete pad or structurally sound deck able to support the dead weight found in the specification chart on the back page WARNING The X2000 Model must not be shimmed in any manner 10 cm 226 cm 610 cm...

Страница 10: ...our exercise system has been filled with water turn it on and test all of the circuit breakers IMPORTANT If breaker immediately trips verify that the wires are correctly connected Breaker should be te...

Страница 11: ...nds then push the breaker switch to the OFF down position to ensure that it has completely disengaged then push the breaker switch to the ON up position If you don t wait 30 seconds the fitness system...

Страница 12: ...he T spacer then remove the T spacer Loosen the 4 screws on the right side corner spacer but do not remove 3 Lift panel and slide left until panel is no longer behind corner 4 While holding panel firs...

Страница 13: ...side Water Feature Levers adjust the amount of water that flows from the water features Jet pump 1 must be on for water feature to work 4 Swim side Water Feature Levers adjust the amount of water that...

Страница 14: ...ystem is equipped with two air valves The air valves will add or remove air to the hydromassage jet system Rotate valve to see which hydromassage jets are affected QUICK START UP INSTRUCTIONS BEFORE Y...

Страница 15: ...of the spa side is complete To turn off the jets press the jets button on the spa side control panel If you do not feel a steady stream of water from your jets refer to the instructions for priming th...

Страница 16: ...confirm When in Economy mode the heating set point will be reduced by 11 C 20 F which means that the heating system will not come on during the set time unless the temperature falls 11 C 20 F below th...

Страница 17: ...ttons to choose the setting that you want to adjust and select it by pressing middle left lit button Use the or buttons to change the parameters and middle left lit button to move between parameters P...

Страница 18: ...and condition of your exercise system and on outside temperatures The set temperature of the swim side water will automatically be 29 5 C 85 F the first time power is applied This is the setting prog...

Страница 19: ...e devices See Wi Fi in the spa side Settings section to connect your swim side to your home Wi Fi network For instruction on how to download theApp to your device search gecko in touch in yourApp stor...

Страница 20: ...ing set point will be reduced by 20 F 11 C which means that the heating system will not come on during the set time unless the temperature falls 20 F 11 C below the set temperature The filtration sche...

Страница 21: ...he time format change the year date and time Use the or buttons to choose the setting that you want to adjust and select it by pressing middle left lit button Use the or buttons to change the paramete...

Страница 22: ...atures The set temperature of the spa side water will automatically be 38 0 C 100 F the first time power is applied This is the setting programmed at the factory After the spa side has been set up and...

Страница 23: ...d for 1 minute purge cycle back to back FILTER CYCLE SUSPENSION The filter cycle will be suspended every time a jet pump or light is activated manually during the filter cycle time The suspension will...

Страница 24: ...ir proper containers Don t inhale fumes or allow chemicals to come in contact with your eyes nose or mouth Wash your hands immediately after use Follow the emergency advice on the product label in cas...

Страница 25: ...er iron and manganese will increase Minimize evaporation by keeping the cover on the exercise system whenever possible High iron or copper content in the water may produce green or brown stains on the...

Страница 26: ...FAC chlorine does not have an odor whereas combined spent chlorine chloramines has a strong chlorine odor that can be eliminated by shocking the water IMPORTANT There are several forms of stabilized...

Страница 27: ...quires changing due to the buildup of soap in the water Typically soap will cause the exercise system water to foam when the jets are used Soap is introduced into the exercise system water from two so...

Страница 28: ...to keep your exercise system filter cartridges clean and free of particles to ensure proper water flow Clean filters enables the hydrotherapy system to function properly and allows for more efficient...

Страница 29: ...side the exercise system remains at the selected temperature The energy efficiency of the exercise system may also decrease during these cold periods as the heater will cycle more frequently As an add...

Страница 30: ...ners out of the reach of children and use care when applying EXERCISE SYSTEM CABINET All exercise systems use the exclusive all climate cabinet designed for years of performance The unique design is m...

Страница 31: ...following factors Thermal overload Although mass produced not all thermal overload cutoffs are exactly the same Some are more sensitive than others and will shut the pump off at lower temperatures Hi...

Страница 32: ...r Overused or old water Clean filters Shock exercise system with sanitizer Add sanitizer Adjust pH and or alkalinity to recommended range Run jets pump s and clean filters Drain and refill the exercis...

Страница 33: ...cartridge Jet blocked Clogged suction or skimmer basket Open air valve Open any closed water valves Clean filter cartridge Remove jet face eyeball and clean orifice Clean suction cover or skimmer bas...

Страница 34: ......

Страница 35: ......

Страница 36: ...5V 3N 24A 50HZ Three phase 24 amp phase GFCI protected circuit F o o t p r i n t d i m e n s i o n s S w i m s i d e e f f e c t i v e f i l t e r a r e a H e i g h t S w i m s i d e h e a t e r W a t...