EDM05-01v6 Time Distribution Server User Guide - Introduction 
 

6 ©2011 

Endace 

Technology 

Ltd.  Confidential - Version 6 - November 2011 

 

Minimum Requirements 

General 

The TDS2 Server Module minimum equipment requirements are: 

 

12VDC to rear panel. 

 

One of the following external time reference sources: 

 

GPS input from Trimble Acutime 2000 GPS Time Receiver, signal type RS422. 

 

CDMA input from Endrun Technologies Praecis Ct CDMA time receiver, signal type RS232. 

 

GPS input from an Endace TTL signal adapter, see 

Accessories

 (page 6). 

 

Standard Ethernet type RJ45-RJ45 cabling for connecting to DAG cards. 

The timing signal ports use RJ45 connectors. These can be connected to a DAG card using normal Ethernet type 
Cat5/6 cable and infrastructure using straight-through type only. 

Note

:

 

Never connect the TDS2 Server module or TDS6 Expansion Units directly to active Ethernet equipment. 

 

Trimble Acutime 2000 

The Trimble Acutime 2000 GPS receiver can be purchased as part of the Acutime 2000 Synchronization Kit – Trimble 
part number 40986-00. The kit includes integrated antenna/receiver, 100ft cable, power supply and signal converter. 
However, only the antenna/receiver and cable are needed for use with the TDS2 Server Module. 

An Endace DB9 to DB25 adapter to connect the TDS2 Module to a Trimble Acutime 2000 receiver is supplied with all 
TDS2 Modules. 

Note:

 

Use only the supplied adapter for this connection. The wiring is different to standard DB9-DB25 adapters available for 

RS232 communications. 

 

Praecis Ct CDMA 

The Praecis Ct CDMA time receiver is available directly from Endrun Technologies Ltd. To use this receiver there must 
be a CDMA network available with good signal at the intended installation site. The signal may be checked using a 
CDMA cellular phone in digital mode. 

 

Accessories 

The following optional equipment is available: 

 

12VDC power adapter 

 

19 inch 1U rack-mount kit 

 

Endace TDS6 Expansion Unit. 

 

Endace TTL adapter. This is for converting TTL signals (BNC connector) to GPS signals (DB9 connector). 

 

Содержание EDM05-01

Страница 1: ...Time Distribution Server User Guide EDM05 01...

Страница 2: ...ate the user s right to operate this equipment in a Class A industrial environment Disclaimer Whilst every effort has been made to ensure accuracy neither Endace Technology Limited nor any employee of...

Страница 3: ...Source 7 Connecting to a Time Reference Source 7 CDMA 7 GPS 7 TTL 8 Connecting to a DAG Card 8 Connecting to a Computer 9 Verifying Time Packets 9 Software Configuration 10 Using the TDS6 Expansion U...

Страница 4: ......

Страница 5: ...tances where it is not practical to run cable to an externally mounted GPS receiver time reference signals from a CDMA cellular network may be used instead CDMA base stations use a GPS receiver to col...

Страница 6: ...r connecting up to two DAG cards Chain out to enable connections of TDS6 modules to provide signal outputs for additional DAG cards from just one external time reference Status LED indicators Accepts...

Страница 7: ...nected to the time synchronization sockets on the front bracket of a DAG card using standard Ethernet cables and patch equipment Product Specifications TDS2 TDS6 Power Supply 12V DC 2 5 A Form Factor...

Страница 8: ...le Acutime 2000 GPS receiver can be purchased as part of the Acutime 2000 Synchronization Kit Trimble part number 40986 00 The kit includes integrated antenna receiver 100ft cable power supply and sig...

Страница 9: ...end to the 12VDC source Caution If you are connecting the TDS Module to an unprotected power source you should use an external 2A fuse Connecting to a Time Reference Source CDMA Follow the steps below...

Страница 10: ...e connect the TTL time source to the Endace TTL adapter below 3 Set the Signal Source switch on the front panel of the TDS2 Module to GPS 4 The PPS LED on the TDS2 Module will flash to indicate it is...

Страница 11: ...the signal is being generated by a CDMA receiver you can view the time packet on the computer using a standard terminal emulator The Trimble Acutime Gold outputs binary formatted data in the serial t...

Страница 12: ...29 0 Trimble Palisade GPS Stratum 1 Set packet delay fudge 127 127 29 0 time1 0 020 and set flag2 to turn off event polling fudge 127 127 29 0 flag2 1 3 Ensure the ntp software is set to start at boot...

Страница 13: ...nchronization outputs derived from a single TDS2 Module connection Each time synchronization output is independently driven The TDS6 Unit power the TDS2 module through the chain cables A TDS6 Expansio...

Страница 14: ...ashing check the TDS2 module is powered and all connections are correct Adding Additional TDS6 Expansion Units You can couple a number of TDS6 Expansion Units together like a daisy chain to extend tim...

Страница 15: ...5 SERIAL Out 6 PPS Out 7 NC 8 NC RS232 DB9 CDMA Input The TDS2 Server Module has one male DB9 input for connecting the Endrun Technologies Praecis Ct CDMA time receiver using standard Ethernet cables...

Страница 16: ...RS422 Chain Output A two port six position six contact modular jack provides direct connection for up to two TDS6 modules The pin out configuration is shown below 1 GND 7 GND 2 PPS Out 8 PPS Out 3 SE...

Страница 17: ...mber 2011 15 DB25 to DB9 GPS Adapter Plug A custom cable will be required when using a DAG card as a time source for a TDS 2 module RJ45 plug to DB9 male or 4 pin connector plug to DB9 male The pin ou...

Страница 18: ......

Страница 19: ...RJ45 modular jack provides time synchronization outputs to the time synchronization input on the DAG card front bracket The pin out configuration is shown below 1 N C 2 N C 3 PPS Out 4 SERIAL Out 5 SE...

Страница 20: ......

Страница 21: ...uary 2009 Minor changes Added TTL and DAG Master cable 4 August 2009 Minor changes Updated Connecting to a Computer 5 December 2009 Updated TDS6 RS422 pin out diagram Added Product specifications 6 No...

Страница 22: ......

Отзывы: