Endace Measurement Systems Limited
http://www.endace.com
EDM01.05-04r1 DAG 3.6GE User Manual
Copyright, all rights reserved.
12
Revision 7. 22 September 2005.
3.5 Inspect Interface Statistics
, continued
Description
,continued
The following example is for a card locked to a 100base-TX stream:
dag@endace:~$ dagthree -d dag0 -si
Spd Lnk FD MA Neg RF JB
100 1 1 0 1 0 0
100 1 1 0 1 0 0
100 1 1 0 1 0 0
The following example is for a card locked to a 1000base-T stream:
dag@endace:~$ dagthree -d dag0 -si
Spd Lnk FD MA Neg RF JB
1000 1 1 0 1 0 0
1000 1 1 0 1 0 0
1000 1 1 0 1 0 0
If the RF or JB bits are 1's, this indicates a problem with the network link.
This may or may not be related to the configuration of the DAG 3.6GE
card.
Check all cabling, ensuring that runs are not too long and that plugs are
firmly clipped into their connectors. Check error condition detectors or
counters on the Ethernet equipment.