ENDA EDT2411A Скачать руководство пользователя страница 4

Holding Register

      Addresses

Decimal

Hex

Data

Type

Data Content

Parameter

    Name

Read/Write

Permission

Status

Value

0000d

0001d

0002d

0003d

0004d

0005d

0006d

0007d

0008d

0009d

0010d

0011d
0012d

0013d

0014d

0015d

0016d

0017d

0018d

0019d

0020d

0x0000

0x0001

0x0002

0x0003

0x0004

0x0005

0x0006

0x0007

0x0008

0x0009

0x000A

0x000B

0x000C

0x000D

0x000E

0x000F

0x0010

0x0011

0x0012

0x0013

0x0014

word

word

word

word

word

word

word

word

word

word

word

word
word

word

word

word

word

word

word

word

word

Digital input types .0=

;1=

;2=

;3=

;4=

nd

EA

SA

HC

dF

Set value

Set point upper limit

Upper level alarm

Set point lower limit

Lower level alarm

The offset value for the cooling

Cooling hysteresis

Switch hysteresis for alarm

Type of buzzer sound

Digital input delay

Delay time for the compressor after power is on.

On time for the compressor output in the case of probe failure

Off time for the compressor output in the case of probe failure

Defrost duration

The time between 2 consecutive defrosts.

Delay time for defrosting after power is on.

After the cooling process of cooling start-up delay

Time delay to display alarm message after alarm is on.

Time delay to display alarm message after power is on.

--

uPL
A.uPL
LoL
A.LoL
oFF
Hy5
A.HY5
5nd
d.inp
ddi
C.Pon

C.Fo5
C.PPn
C.PPf
d.dur
d.int
d.dpo
d.drE
A.dfl
A.dpo

-20

150
150

-60

-60

0
2
2

0

nd

0:00(0 sec)

1:00(60 sec)

0:00(0 sec)

0:00(0 sec)

1:00(60 sec)

1:00(60 sec)

1:00(60 min)

1:00(60 sec)

1:00(60 sec)

0:00(0 sec)

0:10(10 min)

1.1 HOLDING REGISTERS

ENDA EDT2411A DIGITAL THERMOSTAT MODBUS PROTOCOL ADDRESS MAP

Delay time required for the compressor to restart following  a stop.

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write
Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

  Input Register

      Addresses

Decimal

Hex

Data

Type

Data Content

Read/Write

Permission

0000d

0x0000

word

Measured temperature value ( C /  F)

°

°

--

1.2 INPUT REGISTERS

Read

Parameter

    Name

*

 Holding and Input Register parameters of type integer, those “signed integer” is defined as the decimal port of and associated with these

   parameters. (So,”14.0” is a parameter value of “140” will be read in). Relevant parameters for a period of “mm:ss” type ones in seconds, ”hh:mm”
   while those species defined in minutes.

  Discrete Input

      Addresses

Decimal

Hex

Data

Type

Data Content

Read/Write

Permission

0000d

0x0000

Bit

Control output status (0=OFF; 1=ON)

--

1.3 DISCRETE INPUTS

Parameter

    Name

Read

    Coil

Addresses

Decimal

Hex

Data

Type

00d

0x00

Bit

Control type selection.  OFF = 

ON =

Co ,  

HE

C.typ

1.4 COILS

01d

0x01

Bit

Temperature unit.  OFF = 

  ,  ON =

C

F

Unit

02d

0x02

Bit

Decimal point . OFF=

ON=

no  , 

YE5

D.PNT

03d

0x03

Bit

Digital input polarity. OFF = 

 ON =

cL  , 

oP

Dpo

04d

0x04

Bit

Smart Defrost selection.   OFF = 

 ,  ON=

no

YE5

D.5mt

Display configuration during defrost.  OFF = 

  ,  ON =

Lc

rE

D.poN

05d

0x05

Bit

06d

0x06

Bit

Defrost process is started by power-up. OFF = 

  ,  ON =

no

YE5

A.tYP

07d

0x07

Bit

Alarm configuration.  OFF = 

  ,  ON = Relative alarm

Ab5

rEF

D.d5p

Data Content

Read/Write

Permission

Parameter

    Name

Read / Write

Read / Write
Read / Write
Read / Write

Read / Write
Read / Write

Read / Write

Read / Write

4. / 4