background image

EDT1323

 PROGRAMMING DIAGRAM

FAN
LED

  DEFROST
  LED

Compressor

hysteresis

value

If this key is pressed,
COMPRESSOR setpoint
value appears.

Measurement 
temperature

COMPRESSOR 
setpoint value

SET

2/3

RUN MODE

°C

SET

EDT1323

ENDA

  COMPRESSOR
  LED

If this key is pressed,
hysteresis value for 
compressor switch 
appears. 

If this key is pressed,
lower limit of the setpoint
appears.

If this key is pressed,
state of Fan control is
seen,

state of Fan 

control

Lower limit of

 the Setpoint

Rdý

2

  

-50

N

Rll

FaC

PROGRAMMING MODE

Means, thermostat probe is broken or failed or the cold room temperature is out of the 
measurement range.

Means, measured value is out of the adjusted alarm limits.

Means, defrost probe is broken or failed or evaporator temperature is out of the measurement 
scale range.

Er0

Er1

-30

ERROR MESSAGES

Used for increasing the setpoint value, as well as the 

parameter when in programming. When held down for a few 
seconds, the change rate accelerates. 

When held down for 4 second in the run mode, manual defrost 
starts.

Used for decreasing the setpoint value, as well as the parameter 
when in programming. When held down for a few seconds, the 
change rate accelerates.

Used for adjusting the value of the setpoint in

selected parameter in the programming mode.

 the run mode and 

for adjusting the 

Increment 

key

Decrement

key

Programming

key

SET

If both            &              keys are pressed and held for 5 seconds, programming mode is entered.

By using            and              keys while holding                  key, setpoint value

can be adjusted.

SET

By using            and          keys while holding           key, compressor hysteresis

 °C ,   Maximum = 20 °C

  value can

be adjusted to a desired temperature.
Minimum = 1

By using            and          keys while holding           key, 

°C ,   Maximum = the value of the 

ruL

 parameter.

the lower limit of the setpoint can

be adjusted to a desired temperature.
Minimum = -50

By using            and          keys while holding           key, 

fan control can be selected as room 

temperature dependent or not.

SET

SET

SET

The same procedure is also valid for adjusting the other parameters. 

If any no key is pressed within 25 seconds, the device will time out back to the run mode. Alternatively, re-energising the device, 
run mode is entered.

EDT1323

-E-04