1.1.6

Throughput

The BANDIT III chassis has the following system throughput: 

• LAN to WAN, without encryption: 9,000 packets/second, with incoming and outgoing 

traffic at 64 bytes/packet 

• LAN to WAN, with encryption and decryption: 1,800 packets/second, with incoming 

traffic at 50 bytes/packet and outgoing traffic at 100 bytes/packet 

1.1.7

Power Supply 

The BANDIT III is available in models that accept power from a DC power source (at 
-24/-48 VDC or -12/-24 VDC) or in models that accept power from an industry-standard 
autosensing 100/240 VAC adapter connected to an AC power source. A BANDIT III DC-
powered chassis will also accept input from an AC power supply. The BANDIT III’s AC 
power supply converts the AC input power to 5 VDC at 3 amps output for use by the 
BANDIT III chassis. 

Table 1-1. BANDIT III Chassis Standard Port and Power Configurations

Chassis 
Model

IDU Serial 

Ports 

Input Power 
Configuration

Input Power Details

110/220 V 

AC 

-24/-48 V 

DC 

-12/-24 V 

DC 

Basic 
and
ESM 

AC

DC 

Failover DC 
and AC

a

 

Expanded

AC

DC 

Failover DC 
and AC

b

 

a. This is a basic DC chassis (-24/-48 VDC or -12/-24 VDC), with standby AC power. 
b. This is an expanded DC chassis (-24/-48 VDC or -12/-24 VDC), with standby AC power. 

Top Doc

Doc List

Module TOC

Содержание BANDIT III

Страница 1: ...ally hardened chassis with a metal cover Hardened construction allows the BANDIT III to operate over wide temperature ranges at remote sites that do not use environmental control The BANDIT III like a...

Страница 2: ...T III Chassis with Ethernet Switch Module Expanded BANDIT III Chassis with Internal Data Unit BANDIT III E M Signaling Chassis 1 1 1 Standard BANDIT III Chassis The basic BANDIT III chassis Figure 1 2...

Страница 3: ...24 48 volts DC input power Figure 1 5 or for 12 24 volts DC input power Figure 1 6 When you order a BANDIT III you specify the type of input power it will use Note Each DC powered BANDIT III chassis a...

Страница 4: ...nd 110 220 VAC Input Power Figure 1 6 BANDIT III Chassis Rear Panel Basic Model 12 24 VDC Input Power or Failover 12 24 VDC and 110 220 VAC Input Power The following items are on the back of the basic...

Страница 5: ...or X 21 56k CSU DSU port T1 E1 CSU DSU port Dual port T1 E1 CSU DSU port with drop and insert capability A second wireless card this can be the same type CDMA EVDO CDMA GPRS GSM or EDGE GSM as the in...

Страница 6: ...a Unit As stated earlier the BANDIT III is also available in an expanded model with an Internal Data Unit IDU comprising four DB25 serial ports for additional VPN functionality The expanded BANDIT III...

Страница 7: ...igurations for the BANDIT III chassis Two failover input power configurations 24 48 VDC with 110 220 VAC or 12 24 VDC with 110 220 VAC Each BANDIT III chassis that uses DC input power basic Figure 1 4...

Страница 8: ...III is available in models that accept power from a DC power source at 24 48 VDC or 12 24 VDC or in models that accept power from an industry standard autosensing 100 240 VAC adapter connected to an A...

Страница 9: ...connections to network devices Section 1 1 9 1 Ethernet Ports Section 1 1 9 2 Modem Port Section 1 1 9 3 Serial Port Section 1 1 9 4 Wireless Ports Also see Section 1 1 10 Expansion Ports Note The BA...

Страница 10: ...tp SNMP MIB II ARP Proxy ARP Routing over VPN tunnels 1 1 9 2 Modem Port An internal modem resides in the BANDIT III Connect the modem port to an RJ11 telephone jack 1 1 9 3 Serial Port The BANDIT III...

Страница 11: ...ion ports available in the BANDIT III see Ports in the BANDIT Products If the expansion port is for a wireless connection also see Wireless Cards for BANDIT Products 1 2 Status LEDs Light emitting dio...

Страница 12: ...4 indicates that the connection is up between that serial port and its connected device Table 1 6 describes the BANDIT III s LEDs Table 1 6 BANDIT III General Status LED Definitions Sheet 1 of 3 LED...

Страница 13: ...in a set is equivalent to the same number of bars displaying signal strength on a mobile phone Flashes display in one of the following patterns A set of short flashes followed by a longer final flash...

Страница 14: ...ow fifth from left Green Connection has been made to carrier Off Connection to carrier has failed Link for IDU Port 45 Top row sixth from left Green Connection has been made to carrier Off Connection...

Страница 15: ...G Good frames are passing through Byte Sync Encapsulation Good frames are passing through X 25 Level II connection exists Telnet Terminal Data transfer in either direction 1 When using spoofed protoco...

Страница 16: ...Page 16 BANDIT III Reference Module Document 1 Go to Table of Contents Go to Top Doc Go to List of All Docs Top Doc Doc List Module TOC...

Отзывы: