ENC-900 Operating Manual: Chapter 4 Configuration
39
As mentioned previously in this section, there are some settings that can be
changed to the master’s own registers while in diagnostics mode. The most
useful is the unit address. By changing the master’s unit address to that of
another Remote in the network while in diagnostics mode, users can quickly
interrogate/modify many different Remote’s settings without the delays
associated with switching between command and data modes. The
commands which apply to the master’s own registers are shown in Table 5.
Table 5 - Master Diagnostics Commands
Command Master
Register Description
n(x)
-
Remote Hop loading
p
-
Remote IO string read
r(x) S105
Unit
Address
s
S101
back to normal operating mode
t(x) S109
Hopping
Interval
u(x) S104
Network
Address
v(x) S106
Hopping
Pattern
w S123 Local
RSSI
y
-
Remote IO string write
z
S108
Output power level