ENC-900 Operating Manual: Chapter 2 Electrical/Physical
11
Signal strength, which is also reported in Register S123, is calculated based
on the last four valid received packets with correct CRC, and represented by
RSSI1, 2 and 3.
For Remotes, packets are received on every single hop either from a repeater,
or the master.
When calculating RSSI, the master takes into consideration all packets
received from Remotes and repeaters. Repeaters and Remotes only transmit
back to the master when they have information to send. Therefore, if no data
is coming back to the master then RSSI will never get updated at the master,
and the LED’s will be off.
Signal Strength
(dBm)
RSSI1 RSSI2 RSSI3
-95 50%
duty
cycle off
off
-90 on
solid off off
-85
on solid
50% duty cycle
off
-80
on solid
on solid
off
-75
on solid
on solid
50% duty cycle
-70
on solid
on solid
on solid
Table 3 - RSSI mode operation