VE RS I ON
D O CU MEN T TI TLE
RE LEAS E DAT E
03
EL
–
Owner’s Manual
2022-04-29
EL
–
Owner’s Manual –
Rev.04
–
April 2022
19
This is a draft manual, technical specifications are subject to change
4.4.2
VENT CONNECTION GUIDE (H
2
VENT)
Connect the H
2
vent port, located at the bottom left of the front
panel, to your hydrogen vent outlet.
During ramp-up, after ramp down and in regular intervals during
operation, the electrolyser depressurises and releases up to 20
litres of hydrogen within 2 seconds with a loud noise through the
vent line. Please wear PPE earplugs when being close to the
devices. Purging is necessary to release the water which has been
extracted from the hydrogen.
Three EL4.0 and a DR2.1 with common H
2
VENT
Three EL4.0 and a DR2.1 with common H
2
VENT
H
2
OUT and H
2
VENT