APPENDIX A: SYSTEM INTEGRATION
Since the EL2.0 hydrogen generator can be integrated into cabinets or other systems, the scope of this chapter is to
provide technical information in order to allow a safe and proper integration. The user/integrator must comply with
the manufacturer’s instructions descri
bed hereafter.
MANAGEMENT OF AIR FLOWS
The intakes and vents must not be obstructed. To enable a more compact design a front to back airflow approach
has been taken.
The air flow must enter from the front and exit from the back, passing through the modules.
CABINET
The front side of the EL2.0 must be accessible in order to manage all electrical and mechanical connections and
maintain the devices. The front must allow air to flow into mounted systems, as all Enapter systems will feature front
to back airflow. The rear side of the cabinet must allow the hot air exhaust to escape unobstructed.
When integrating the modules into a cabinet not supplied by Enapter, the following should be considered, please
also note the values for airflow management through the cabinet below.
1)
A continuous air flow of minimum 50 m
3
/h must be guaranteed.
2)
A max. air flow of 800 m
3
/h should be possible, it will be used to adjust the cabinet temperature.
3)
We recommend maintaining the max. cabinet temperature below 40 °C.
4)
The cabinet air inlets must be equipped with proper filters to avoid the penetration of dirt into the cabinet.
They must be kept free from obstructions/filth and they must have at least 30 cm of clear space to allow a
regular air flow passage.
Input air flow
3
Output air flow
3