Page 97
1.3.10 Post Heatin...
04. 07. 2015
10:37
Activation
Ref. temp.
Starting time
End time
45.0°C
00:00
23:59
1.3.10 Post Heatin...
04. 07. 2015
10:37
Ref. temp.
Starting time
End time
Time period
45.0°C
00:00
23:59
Weekends
1.4 Efficiency funct...
04. 07. 2015
10:38
Low-Flow
Quick-charging
Disable recharge
Efficient tank-charge
PROFESSIONAL MODE
›Ref. temp.‹ is used to define the set
temperature at the top tank sensor.
If the temperature falls below ›Ref. temp.‹
by ›Hysteresis‹, the control activates the
reheating cycle via the heating boiler until
›Ref. temp.‹ is reached.
Each period can be defined with ›Saturday‹,
›Sunday‹,›Weekends‹, Monday - Sunday‹ or
›Monday - Friday‹.
Continue with ›Efficiency functions‹.
The following items appear under
›1.4. Efficiency funct.‹ next to
the operation mode menus:
- ›Low-Flow‹
- ›Quick-charging‹
- ›Efficient tank-charge‹
Call up menu item ›Low-Flow‹.