background image

EMX Industries, Inc.                                                Tech support: 216-518-9889 

5/9

 

Document No.10579100 Rev 2.5                              [email protected]

 

 

Programming Options  

 

Enter/Exit Programming Mode 

 

       Enters programming mode. Orange LED should turn on.  
       

You must enter programming mode to enter any code. 

       Exits programming mode. 

Programming Key  * 

 

 

 

Super User Keys 

 

Owner’s multi-task user key. Can be used to escape from locking mode. 

 

4  5 

 

4-8 digits  # 

Duress Keys 

 

4  6 

 

0-9 

 

4-8 digits  # 

 
Duress keys activate output 1 and duress outputs 
simultaneously to report a user is under duress.  
10 duress keys may be used at once.

 

Visitor Keys 

 User ID    Operation Time                                       

 

4  7 

 

0-9 

 

00-99 

 

4-8 digits  # 

 

10 visitor keys may be used at once. 
Operation Time:  
00 = one-time use only 
01-99 = valid for xx hours 

Single User Mode/Reset 

*Only use to change modes will erase user codes and 
programming code. Must add programming code back after 
change* 

 

8  9 

0  # 

Sets the mode and clears all previously stored data and modes. Single 
user mode assigns one user key per relay.  

 

Multi-User Mode/Reset 

*Only use to change modes will erase user codes and 
programming code. Must add programming code back after 
change*

 

 

8  9 

1  # 

Sets the mode and clears all previously stored data and modes. Multi-
user mode assigns up to 100 user keys for relay 1 and up to 10 user 
keys for relay 2.

 

Relay Output Mode Configuration

 

 

Output 1 

40 

 

1-999  # 

 

 

 

 

 

Output 1 

41 

 

 

 

 

 

 

 

Output 2 

50 

 

1-999  # 

 

 

 

 

 

Output 2 

51 

 

 

 

Momentary Mode:  
Keeps OUTPUT 1 triggered for 1-999 seconds upon user key entry.  

 

Start/Stop Mode: Keeps OUTPUT 1 triggered until re-entry of user 
key. 

 

Momentary Mode: 
Keeps OUTPUT 2  triggered for 1-999 seconds upon user key entry. 

 

Start/Stop Mode: Keeps OUTPUT 2 triggered until re-entry of user 
key. 

 

Note:

 Output 2 may be used as a supervisor mode to disable 

Output 1 if wired in series. 
 

Содержание KPX-100

Страница 1: ...nmental Rating IP66 Operating Temperature 4º to 158ºF 20º to 70ºC 5 to 95 relative humidity Housing Material Powder coated steel with stainless steel faceplate Dimensions L x W x H 6 14 156 mm x 4 1 103 mm x 2 76 50 mm Specifications Status Tones Left LED Orange LED Right LED Programming Mode Flashes Successful Key Entry Relay 1 Determined by code 81 1 flash Solid green LED Successful Key Entry Re...

Страница 2: ...o ground after a duress key has been entered It is often used to trigger an alarm an auto dialer or a buzzer 12 Common Ground 13 Door Position Sensor Input N C normally close input terminal See door sensor wiring diagram to the right Always connect terminal 13 to ground if not in use 14 Output 1 Inhibit N O normally open input terminal Both relay 1 user keys and egress button cannot activate outpu...

Страница 3: ... two KPX 100 with cross wire connections on the output 1 inhibit 14 and inter lock control output 15 terminals Connect the common ground terminals 12 of the two keypads Use N O relay output for fail secure locking and N C output for fail safe locking An inter lock system prevents both doors from being open at the same time for a more secure entry Keypad Back Lighting jumper selected 1 Backlit The ...

Страница 4: ...8 digits of your choice followed by 0 5 To change the programming key press 0 and then 4 digits of your choice followed by 0 6 To create user keys for relay 1 and 2 press the relay number the user number and then 4 8 digits of your choice followed by Relay 1 can have 100 user keys relay 2 can have 10 user keys User keys must be the same length as the programming key if planning on using auto entry...

Страница 5: ...ase user codes and programming code Must add programming code back after change 8 9 0 0 Sets the mode and clears all previously stored data and modes Single user mode assigns one user key per relay Multi User Mode Reset Only use to change modes will erase user codes and programming code Must add programming code back after change 8 9 0 1 Sets the mode and clears all previously stored data and mode...

Страница 6: ...n the door is forced open Output through terminal 13 Correct Key Entry Tones 8 1 0 8 1 1 8 1 2 Keypad does not beep upon correct key entry Keypad beeps twice upon correct key entry Keypad beeps once upon correct key entry default User Key Entry Mode 8 2 0 8 2 1 Requires after user key is entered default Keypad does not require after user key is entered All user keys must match Programming key leng...

Страница 7: ... 5 seconds the keypad will beep before output 1 activates Press and hold the egress button for 10 seconds the keypad will beep before output 1 activates Troubleshooting Symptom Possible Cause Solution Forgotten programming key Forgotten programming key 1 Disconnect the power supply 2 Move the DAP jumper from OFF to ON 3 Reconnect the power supply The keypad will start beeping 4 Move the DAP jumper...

Страница 8: ...tion Record Loc Code Loc Code 00 50 01 51 02 52 03 53 04 54 05 55 06 56 07 57 08 58 09 59 10 60 11 61 12 62 13 63 14 64 15 65 16 66 17 67 18 68 19 69 20 70 21 71 22 72 23 73 24 74 25 75 26 76 27 77 28 89 29 79 30 80 31 81 32 82 33 83 34 84 35 85 36 86 37 87 38 88 39 89 40 90 41 91 42 92 43 93 44 94 45 95 46 96 47 97 48 98 49 99 ...

Страница 9: ... support 216 518 9889 9 9 Document No 10579100 Rev 2 5 technical emxinc com EMX Industries Inc products have a warranty against defects in materials and workmanship for a period of two years from date of sale to our customer ...