Wiring Connections 

 

11 Pin Connector Assignments 

 

 

  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

 

 

1  Power + (9-41 VDC or 6-29 VAC)  

7  Probe (red wire) 

2  Power 

 (9-41 VDC or 6-29 VAC) 

8  Probe (black wire) 

3  RELAY 1 

 NO (normally open contact) 

9  RELAY 2 

 NO (normally open contact) 

4  RELAY 1 

 COM (common contact) 

10  RELAY 2 

 COM (common contact) 

5  RELAY 1 

 NC (normally closed contact) 

11  RELAY 2 

 NC (normally closed contact) 

6  Probe shield wire & earth ground (provides connection for transient and noise 

suppression devices) 

IMPORTANT:  EARTH GROUND CONNECTION 

 

The  CS101  contains  transient  protection  devices  to  guard  the  sensitive  electronic  circuitry  from 
damage  and  false  triggering  due  to  electrical  transients  caused  by  lightning  or  other  sources.  
Always  provide  a  good  earth  ground.    An  8

  copper  rod  or  metal  cold-water  pipe  provides  a 

sufficient  earth  ground  connection.    Both  the  probe  shield  and  PIN  6  of  the  CS101  must  be 
connected to this earth ground. 

 

Power + 

Probe black wire 

Probe red wire 

Probe shield wire 

Relay 2 connections to  

“open only” terminals in 

operator or annunciator 

Connect terminal 6 and  
earth ground 

 

8' earth ground rod 

Power 

 

Relay 1 connections to  

“open only” terminals 

 

in operator or annunciator 