UVX-Tin-side Detection System Operating Instructions
 

 

Document no. 10010604 

 

 

 

Operation 

 

Power Up 

Upon power up, the sensor initializes by turning on all segments on the display and sequencing 
through red, yellow and green on the status LED located above the display.  The green LED on 
the Optical Unit indicates power.    

 

Intensity Display Mode 

During normal operation the sensor display will indicate the relative intensity of a target within 
its  field  of  view.    The display  is  useful primarily  during  set-up and adjustment  of  the  sensor.  
During normal operation where there is movement of the samples/targets, the display is not 
generally useful since the display update rate is about 3x/sec.  The range of the relative intensity 
display is 00 through 99.  The decimal points on the display indicate the LED output intensity.  No 
decimal points indicate low, one decimal point indicates medium and two decimal points indicate 
high intensity.   

 

Calibration Adjustment  

The calibration feature allows the displayed measurement to be adjusted to the desired value by 
the user.

   

Adjusting the measured value: 

 

1.

 

Pl

ace target in sensor’s field

-of-view.  The sensor will display the current reading.   

2.

 

Press either key (for less than 3 seconds); while the current reading is displayed the value 
is flashed slowly indicating that the sensor is in the adjustment mode.  

3.

 

Press T/+ to increment the reading and P/- to decrement the reading. 

4.

 

Stop pressing a key and sensor returns to normal operating mode in 3 seconds. 

 

Note: 

 

While adjusting the reading, when a limit is reached the display flashes at a faster rate. 

 

The selected gain is stored in memory and is retained when power is removed. 

Local Lock 

The  local  lock  feature  allows  the  sensor  to  be  locked  out,  preventing  adjustments  by 
unauthorized personnel.  To lock the sensor, press the 

P/-

 and 

T/+

 buttons for 3 seconds until 

LL

 

is displayed.  To un-lock the sensor, press the 

T/+

 and 

P/-

 for 3 seconds until 

LL

 is not displayed.  

While the sensor is locked, pressing either

 P/-

 or 

T/+ 

will result in 

LL 

(

L

ocal 

L

ock) indication on 

the display. 
 
 
 
 

 

 

Содержание UVX-TIN-SIDE

Страница 1: ...O N S Operating Instructions 4564 Johnston Parkway Cleveland Ohio 44128 P 800 426 9912 F 216 518 9884 Sales Inquiries salessupport emxinc com Technical Support technical emxinc com www emxinc com UVX...

Страница 2: ...mized as described in this Instruction to achieve maximum life For this reason the LED is not covered by the manufacturer s warranty Connect an earth ground to the stud on the Optical Unit using minim...

Страница 3: ...ted at approximately 5 10mm from the surface of the glass A green LED indicates that the Optical Unit is powered The enclosure provides 4 mounting holes or 2 for the UVX tin side mini for user supplie...

Страница 4: ...ut Pulse 0 90 mS 10 steps Output Function NO NC selectable On Off Delay 150 uS Security LOCK UN LOCK keypad Power indicator Green LED Detect indicator Red LED Programming indicator Yellow LED Data ret...

Страница 5: ...ntensity Calibration Adjustment The calibration feature allows the displayed measurement to be adjusted to the desired value by the user Adjusting the measured value 1 Place target in sensor s field o...

Страница 6: ...T key until the value approaches 99 then wraps around to 00 LED Intensity Level U The LED intensity is indicated on the display as U1 U2 and U3 for low medium and high intensity Press and release the...

Страница 7: ...to identify the tin side of float glass by projecting the UV light source onto the target surface When the tin side is present the surface will emit light in the visible spectrum The receiver optics m...

Страница 8: ...to allow adjustments of sensor parameters 6 Connect the cable between the Optical Unit and the Control Unit 7 Connect the Control Unit wiring to the power source and PLC If necessary connect LED Enabl...

Страница 9: ...ors must not be connected in parallel Parallel connections may damage sensor output circuitry Analog Output The analog output is 0 5V with 20mV resolution 8 bit Any standard analog input channel typic...

Страница 10: ...d Mode while in Detect Display decimal points None illuminated LED low intensity One illuminated LED medium intensity Two illuminated LED high intensity M12 Connector Pin Assignments M12 Connector Wir...

Страница 11: ...ument no 10010604 Ordering Information UVX 300G C CU Control Unit OU TS2 Optical Unit M12 10 2 MF Cable 10P 5M M12 M F 240 240025 Power supply 24VDC regulated Accessories UVX300 BRKT UVX 300 C Bracket...

Страница 12: ...mal wear and tear abuse misuse overloading altered products damage caused by incorrect connections lightning damage or use other than intended design There is no warranty of merchantability There are...

Страница 13: ...ions 12 Document no 10010604 4564 Johnston Parkway Cleveland Ohio 44128 United States www emxinc com Technical Support 216 834 0761 E mail technical emxinc com Sales 216 518 9888 Fax 216 518 9884 E ma...

Отзывы: