IRB-MON Operating Instructions
2
Document no.
10280104
Cautions and Warnings
1.
Read and follow all operating and Installation instructions.
2.
Always follow gate operator manufacturer installation instructions regarding
installation of TYPE B1 sensor to the operator.
3.
Disable the gate so it is unable to move.
Refer servicing to qualified service personnel.
IMPORTANT:
This product is an accessory or part of a system. Always read and follow the manufacturer’s
instructions for the equipment before connecting this product. Comply with all applicable
codes and safety regulations. Failure to do so may result in damage, injury or death.
Product Overview
The IRB-MON is a thru-beam photo eye and is an external entrapment protection device type
B1, non-contact sensor for use with automatic gates and doors. The light beam is near
infrared and pulses at a rate of 300/second (300Hz). The IRB-MON provides a signal to the
gate or door operator that the beam is not obstructed. The operating range is up to 115ft. The
IRB-MON operates over a wide range of 6-35VDC and 12-24VAC.
A green alignment indicator on the receiver provides status information at a glance, making
set-up and alignment easy.
The IRB-MON includes 3 selectable operating configurations providing compatibility with most
operators that accommodate monitored external entrapment protection devices per UL325-
2016.
REFER to operator installation instructions for proper configuration selection.
CONFIGURATION 0 - NON-MONITORED and MONITORED
Intended for use with operators that require simple relay contact activation to
indicate beam obstruction. Reference Light ON/Dark ON setting. Jumper
available for compatibility with Normally Open 10K termination operators.
CONFIGURATION 1 – MONITORED, HEARTBEAT 300Hz / 0Hz
Intended for use with operators designed to accept a “heartbeat” form of
monitoring, 300Hz when aligned, no obstruction, 0Hz when beam is obstructed.
CONFIGURATION 2 – MONITORED, HEARTBEAT 300Hz / 2Hz / 0Hz
Intended for use with operators designed to accept a “heartbeat” form of
monitoring, 300Hz when aligned, no obstruction, 2Hz when beam is obstructed,
and 0Hz for a failure.