CarSense 303™ Operating Instructions
9
Document no.
10310104 Revision 1.8
11/1/2016
Probe
HORIZONTAL INSTALLATION
Horizontal
installation
can
be
accomplished by cutting out a 3” x 1.5” x 5”
area in the pavement, with a 5/16” x 2”
deep saw cut exiting the cutout for the
communications/power cable. Backer rod
should be place at a minimum of every 10-
14”. Pavement sealant can then be used
to fill the cable and probe cavities.
VERTICAL INSTALLATION
For vertical installation, drill a 7” x 1.5” hole
in the surface with a 5/16” x 2” deep saw
cut
exiting
the
cutout
for
the
communications/power cable. Backer rod
should be place at a minimum of every 10-
14”. Pavement sealant can then be used
to fill the cable and probe cavities.
Flat Pack
HORIZONTAL INSTALLATION
The flat pack requires a 2” x 3/8” x 6” cut in
the pavement for the sensor, with a 5/16”
x 2” deep saw cut for the cable lead.
Backer rod should be place at a minimum
of every 10-14”. Pavement sealant can
then be used to fill the cable and sensor
cavities.
Installation