LPe15004, LPe16004, and LPe16000B-series HBA Installation Manual
P008875-02A Rev. A
2. Installation
Viewing the LEDs
14
Internal ASIC RAM tests for proper ECC and parity operation
NLPort loopback test
The following table summarizes POST conditions and results:
Note:
For the Link Rate conditions, there is a 1 second pause when the LED is off
between each group of fast blinks (2, 3, or 4). Observe the LED sequence for
several seconds to be sure you have correctly identified the pattern.
Table 2-2
POST Conditions and Results
Green LED
Yellow LED
State
Off
Off
Boot failure (Dead board)
Off
On
POST failure (Dead board)
Off
Slow Blink
Boot failure after POST
Off
Fast Blink
Not Defined
Off
Flashing
POST processing in progress
On
Off
Failure in Common Code Module
On
On
Failure in Common Code Module
On
1 Fast Blinks
Normal (Link up at 2GFC) (legacy
compatibility only)
On
2 Fast Blinks
Normal (Link up at 4GFC)
On
3 Fast Blinks
Normal (Link up at 8GFC)
On
4 Fast Blinks
Normal (Link up at 16GFC)
On
Flashing
Not Defined
Slow Blink
Off
Normal-link down
Slow Blink
On
Not Defined
Slow Blink
Slow Blink
Not Defined
Slow Blink
Fast Blink
Not Defined
Slow Blink
Flashing
Not Defined
Fast Blink
Off
Not Defined
Fast Blink
On
Not Defined
Fast Blink
Slow Blink
Not Defined
Fast Blink
Fast Blink
Beaconing
Fast Blink
Flashing
Not Defined