Operating instruction for collet holder
type Softsynchro
®
/ PGR
6
Edition: 01.04.2012
®
2 Putting the collet holders into operation
2.1 Unpacking
-
Take the collet holder from the packing
-
Clean the collet holder with a duster to remove any conservation oil
Clean the collet holder as described in the cleaning directions, see chapter
2.6.1,
page 9.
⇒
The collet holder is now ready for operation
Exception
:
Type with
hollow taper shank (HSK).
Please refer to chapter
2.4, page 7, for how to put
this collet holder into operation.
2.2 First putting into operation
For collet holders with HSK-shank (hollow taper shank) the coolant-lubricant pipe
must be mounted prior to putting into operation, see chapter
2.4, page 7.
The collet holders are inserted into the machine manually or - if provided - by the tool
exchanger.
The exchange of the collet holder must not be executed while the machine
spindle rotates!
-
Only use tool shanks and tightening bolts suitable for the specific machine.
-
Make sure the tool is correctly clamped.
⇒
Risk of accident by spinning of the tool!
-
Please see also the indications in the operating instruction of your machine
tool!
2.3 Re-putting into operation
If the collet holder is reputed into operation as described in chapter
4, page 11, please go
through the following steps:
-
Clean the collet holder with a duster to remove any conservation oil
Do not use any aggressive solvents.
Do not use fibrous materials i.e. steel wool.
-
Clean the powRgrip
interface of the tap holder as described in the cleaning directions
-
Insert the collet holder into the machine as described in chapter
2.2.