2  Putting the quick-change tap holders into operation 

 

2.1  Unpacking 

  Take the quick-change tap holder from the packing 

  Clean the  quick-change tap holder with a  duster to remove any conservation 

oil 
 

            

Note  

      

Do not use any aggressive solvents. 

 

   Do not use fibrous materials i.e. steel wool. 

 

 

The quick-change tap holder is now ready for operation. 

 

Exception: 

Type with 

hollow taper shank (HSK)

. Please refer to chapter 2.4.1 page 9, for how 

to put this quick-change tap holder into operation. 

 

2.2  First putting into operation 

            

Note  

For  quick-change  tap  holders  with  HSK-shank  (hollow  taper  shank)  the  coolant-
lubricant  tube  must  be  mounted  prior  to  putting  into  operation,  see  chapter  2.2.1,   
page 8 

            

 When working with internal coolant supply: 

     The tap holders are made for coolant pressures up to 

50 bar

 

 
 

             

Attention  

The exchange of the tool must not be executed while the machine spindle rotates! 

 

    Only use tool shanks suitable for the specific machine. 

 

    Make sure the tool is correctly clamped. 
    Otherwise: Risk of accident by spinning of the tool! 

 

    Please see also the indications in the operating instruction of your machine tool! 

 

Содержание FRANKEN Softsynchro 6

Страница 1: ...Softsynchro 6 Quick change tap holder Softsynchro 6 Operating instruction...

Страница 2: ...putting into operation 7 2 2 1 Assembly of the coolant lubricant tube for quick change tap holders with hollow taper shank according to DIN 69893 HSK A 8 2 3 Re putting into operation 9 2 4 Quick chan...

Страница 3: ...ction the following symbols are used Attention Marks special instructions rules and prohibitions which are important in order to avoid any damage Please observe these instructions Note Marks applicati...

Страница 4: ...axial force during the thread producing cycle is reduced to a minimum The resulting advantages are No mis cutting of the threads Optimised tap cold forming tap life Normally the quick change tap holde...

Страница 5: ...y mis operating Hold the tool when loosening the tool clamping to avoid it falling down and damaging the tool and the work piece Keep the tool adaption clean There are maximum values for cutting speed...

Страница 6: ...Softsynchro 6 Type Cutting range Quick change adapter D mm C 1 mm T 2 mm Maximum coolant pressure bar D1 mm D3 mm Softsynchro 6 M45 M76 1 2 HE 2 IKZ Z 110 2 2 50 75 110 Further outer dimensions of the...

Страница 7: ...how to put this quick change tap holder into operation 2 2 First putting into operation Note For quick change tap holders with HSK shank hollow taper shank the coolant lubricant tube must be mounted...

Страница 8: ...t coolant lubricant tube in the shank Note Required tool Choose appropriate assembly wrench for the shank size For the assembly wrench please refer to the EMUGE main catalogue category accessories 1 P...

Страница 9: ...ion of the tap cold forming tap is executed via quick change adapters The following quick change adapters are available Type HE2 IKZZ Design for taps cold forming taps with internal coolant lubricant...

Страница 10: ...Z Z Hexagon socket wrench width across flats 4 1 Push tap cold forming tap into the adapter Note Bring square into correct position by turning the tool 2 Tighten all three screws equally Note Tighteni...

Страница 11: ...2 Push grip sleeve in direction of the holder shank and hold it 3 Push in quick change adapter Note The drivers of the holder must be located in the grooves of the adapter 4 Pull the grip sleeve forwa...

Страница 12: ...xecuted while the machine spindle rotates 1 Push grip sleeve in direction of shank and hold it 2 Remove quick change adapter 3 Let go of grip sleeve Note The instruction is valid for quick change tap...

Страница 13: ...ed tool Type HE 2 IKZ Z Hexagon socket wrench width across flats 4 1 Loosen the three screws 2 Remove tap cold forming tap Note The instruction is valid for all quick change adapters types HE 2 IKZZ a...

Страница 14: ...ny aggressive solvents Do not use fibrous materials i e steel wool Do not clean and dry the quick change tap holder in an automatic washplace as a result the built in dampers and seals may be damaged...

Страница 15: ...Softsynchro 6 Operating instruction edition 01 04 2018 15 Notes...

Страница 16: ...ginal in German Edition 2 last change 01 04 2018 change stage 1 Please keep the operating instruction for future use EMUGE Werk Richard Glimpel GmbH Co KG Fabrik f r Pr zisionswerkzeuge N rnberger Str...

Отзывы: