EMTRON EIC USER MANUAL
WWW.EMTRON.WORLD
© EMTRON AUSTRALIA PTY LTD APRIL 2018
19
4.23 ECU CAN Configuration for Multiple Devices
The next step is to configure an ECU CAN channel, allowing the ECU to decode the EIC CAN
packets.
Only 1 CAN Channel is required for multiple devices. CAN 1 - Channel 4 has been selected.
Config as follows:
1.
Set “Enable" to 1(ON)”
2.
Set "CAN Base Address" to
the
Lowest
Base Address ID
shown in Figure 4.8. In this
example its 718.
3.
Set "DATA Set" to 74 -
Emtron EIC10 2x Devices
(CAN PID 718/722).
The ECU is now configured and will receive data from all devices on IDs 718-721, 722-725.
NOTE
: You only need to program in the lowest Base Address. The ECU automatically
configures the remaining IDs based on the assumption that the IDs are sequential in order.
4.24 EIC Data Monitoring for Multiple Devices
To confirm the EIC10 data from multiple devices is
being decoded by the ECU, open the Runtime menu
(F3) -> Emtron CAN Device Tab to view the live data.