EMS FirePoint System 5000 Скачать руководство пользователя страница 6

EMS 5000 FIREPOINT 

 

 

©2015 EMS Security Group Ltd. All rights reserved.                                              TSD234 Iss 3 25/06/15 AJM 

 

4. Engineers Control Panel Quick Guide for Radio LAN Communication 

|**

Main Menu

**|

 

Pins & Access 
System Support 
Serial Comms 
Pager Setup 
Engineers Ctrl 
Time & Date 
Output Setup 
Logging 
Remote Rxers 
Ext.Comms 
Bus I/O 
Fire dbase 
Checksum Data 
Network Router

 

Radio LAN 
Fire DB 
^^^^^^^^^^^^^ 

|*Serial Comms*| 
Device Table 
Re-Start Bus 
Re-Online Device 
Bus Master Setup 
Bus Remote Setup

 

Pager 232 Redir’ 
Aux 232 Redirect 
Printer Redirect 
Monitor Comms

 

Delete Device 
^^^^^^^^^^^^^^^^

 

|*Master Setup*| 
Polling Baudrate 
Auto Re-online 
Port to use 

|*Remote Receivers*| 
Receivers Found 
Enable Receiver 
Enable Collector 
Monitor traffic

 

^^^^^^^^^^^^^^^^

 

 
 

Polling Baud 
Is 384, Enter rate 
(MAX 768): 
YES = Finish    TIME

 

Master Port =1 
0=Off, 1 = RS485 
2=PAGER 232

 

Local   NUA  :  00 
Input  Local  NUA 
YES = Finish   TIME

 

|*Network Router*| 
Setup local NUA 
View Network NUA 
Network Name 
Control Routing 
Send Test

 

Rem Rxer : DISABLED 
Push YES to change 
Push NO to escape 
Push YES/NO    TIME

 

 

Collector : ENABLED 
Push YES to change 
Push NO to escape 
Push YES/NO    TIME

 

 

Routing : ENABLED 
Push YES to change 
Push NO to escape 
Push YES/NO    TIME

 

 

|***Radio LAN***| 
Node Table 
Re-Start LAN 
Re-Online Node 
Node Setup 
Add/Delete Node 
Advanced 
^^^^^^^^^^^^^^^^

 

|***  Node Setup ***| 
Node Address: 1 
Set as: Master 
Site ID:2047 
LAN Module NUA: 04 
Auto Log ON: OFF 
^^^^^^^^^^^^^^^^^^^^

 

|* Remote Setup *| 
Reply Baudrate 
Port to use 
^^^^^^^^^^^^^^^^^^

 

Remote Port = 0 
0 = Off, 1 = RS485 
2 = PAGER232 >

 

|  ***  Advanced  ***  | 
   Poll Int:              60 
   Init Poll Int:        10 
   Poll Timeout: 3600 
   Delete All Nodes 
   Clear Missed Polls 
   Monitor Node 
   ^^^^^^^^^^^^^^^^^^

 

**Note** The Poll 
Int Timer Values 
will vary. Please 
refer to the table 
on page 13 for 
the applicable 
value  

Re Initialising Bus 
Please wait *Done* 
Push any key to continue 

Enter Node Address 
(Numbers 2-30) 
Number > _ 
Yes = Finish         TIME 

 

Monitor Node  
(Numbers 2-30) 
Number > _ 
Yes = Finish         TIME 

 

| ***    Delete Node    *** | 
Slot :                2 
NONE 
Slot :                3 
ONLINE 
Slot :                4 
ONLINE 

 

Содержание FirePoint System 5000

Страница 1: ...5000 RADIO LAN COMMUNICATION GUIDE...

Страница 2: ...RICAL INSTALLATION 4 5 FACTORY SUPPLIED PRE PROGRAMMED SYSTEMS 6 5 FACTORY SUPPLIED PRE PROGRAMMED SYSTEMS 7 6 SHOULD A LAN UNIT GO OFFLINE ON THE 485 BUS 7 7 SHOULD THE RADIO LAN GO OFFLINE 8 8 MONIT...

Страница 3: ...ls together The Radio LAN Module is hardwired to it s allocated control panel via a 2 core screened fireproof cable This then enables communication between control panels via radio therefore the need...

Страница 4: ...screws situated on the front lid The front section of the unit can now be removed Check that the front tamper switch operates when the lid is removed Should the microswitch not operate carefully adjus...

Страница 5: ...EMS 5000 FIREPOINT 2015 EMS Security Group Ltd All rights reserved TSD234 Iss 3 25 06 15 AJM 5...

Страница 6: ...Finish TIME Network Router Setup local NUA View Network NUA Network Name Control Routing Send Test Rem Rxer DISABLED Push YES to change Push NO to escape Push YES NO TIME Collector ENABLED Push YES to...

Страница 7: ...he master panel will automatically try to re online the pre programmed slave panels This can take up to 5 minutes to complete With control panels offline an OL fault will be displayed at the master pa...

Страница 8: ...bove The offline fault should clear from the panel 7 Should the Radio LAN go offline The following type of fault screen should be displayed Should such a fault be listed as previously shown the node p...

Страница 9: ...odes Panels Nodes can be checked for the amount of polls missed by checking the individual node s missed poll counter This will give an indication of the signalling between panels on the network As a...

Страница 10: ...e number The third row details values of information that is currently being sent The fourth line gives information of the nodes current status Eg Online or Offline With reference to the second line b...

Страница 11: ...peater panels are allowed on each system To change panel s to have this functionality at the main panel Access the Main menu Scroll down to Fire DB and press the YES key Now scroll down the menu until...

Страница 12: ...21100 then press the YES key and the screen will now display 6 Press the button until the screen displays 7 Press the YES key followed 0 key on the Keypad the screen will now display 8 Press the butto...

Страница 13: ...ll now display 19 Press the button until the screen displays 20 Press the YES key The screen will now display Re online Device Bus Master Setup Bus Remote Setup Yes Select Time Master Setup Polling Ba...

Страница 14: ...y 30 The Rem Rxer should be set to DISABLED press the YES key to change Otherwise press the NO key The screen will display Reply Baudrate Port to use Yes Select Time Remote Port 0 0 Off 1 RS485 2 PAGE...

Страница 15: ...utton until the screen displays 40 Press the YES key and the screen will display 41 The Routing should be set to ENABLED If already set press the NO key If DISABLED press the YES Key followed by the N...

Страница 16: ...ote The Site ID is factory set and can only be altered by entering an EMS engineering password Note This must match on all control panels on the radio board network for communication to take place 48...

Страница 17: ...al timer value varies depending on the number of slave panels within the system The time can be calculated using the table below Number of Slaves including Mimics Applicable Poll Interval Timer Values...

Страница 18: ...EMS 5000 FIREPOINT 2015 EMS Security Group Ltd All rights reserved TSD234 Iss 3 25 06 15 AJM 18...

Страница 19: ...S key followed by entering 3600 Now press the YES key and the screen should display 58 Now press the NO key until the screen displays 59 Turn the control keyswitch to the off position and the screen w...

Страница 20: ...cies UHF 458 5 459 5 MHz Transceiver Operating Temperature 10 to 55 degrees C Humidity Up to 75 non condensing Channel Spacing 25 kHz Output Transmitter Power 0 75W 500 mW 27DBH Supply 230v ac Current...

Страница 21: ...EMS 5000 FIREPOINT 2015 EMS Security Group Ltd All rights reserved TSD234 Iss 3 25 06 15 AJM 21...

Страница 22: ...EMS 5000 FIREPOINT 2015 EMS Security Group Ltd All rights reserved TSD234 Iss 3 25 06 15 AJM 22...

Отзывы: