![EMS EkoMini Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/ems/ekomini/ekomini_operators-manual_2404722030.webp)
EMS
Wireless
EMS
Wireless
EkoMini Manual
30
4.10 Factory Default Software Settings:
The EkoMini
TM
is shipped from the factory with these default settings:
KTIME = 03:30 (24 hr.format)
KACTV = No
KTYPE = Answer
KMESS = None
KRING = 5
KCODE = Serial Number
KDIAL = 000
KRTRY = 3
RP # DIAL = 000
RP # PINN = 000
RP # DLAY = 5
RP ACTV = No
RP TYPE = Number(serial)
PW 1 = 11111
PW 2 = 10000
PW 3 = 10001
UN = Serial Number
AR = 2
5.0 Technical Description
5.1 Power Control
Power control is a key factor that differentiates the EkoMini
TM
repeater from many other
bi-directional amplifiers. The power control features found in the EkoMini
TM
are based
on software algorithms that make this repeater well suited to a wide variety of signal
level environments.
Power control begins with the automatic software setup when the EkoMini
TM
is
powered up. Minimum attenuation is automatically set (maximum gain setting). Then,
the unit constantly monitors the output power level at the donor port while increasing
attenuation (decreasing gain) until the user settable output power level (described