Single Phase Motor Energy Control - Page 11 of 20
4.1.1 4A AND 10A PCB CONNECTOR IDENTIFICATION
TERMINAL
LOCATION
FUNCTION
L
PCB
Supply Input Positive
L
PCB
Supply Input Positive Auxiliary
N
PCB
Supply Input Neutral
N
PCB
Supply Input Neutral Auxiliary
E
PCB
Supply Input Earth
E
PCB
Supply Input Earth Auxiliary
MOTOR L
PCB
Motor Feed Positive
MOTOR N
PCB
Motor Feed Neutral
MOTOR E
PCB
Motor Feed Earth
4.1.2 25A CONNECTOR IDENTIFICATION
TERMINAL
LOCATION
FUNCTION
Input L
Base Plate Connector
Supply Input Live
Input N
Base Plate Connector
Supply Input Neutral
Motor L
Base Plate Connector
Motor Feed Live
Motor N
Base Plate Connector
Motor Feed Neutral
Earth
Base Plate Connector
Earth
4.2 SETTING UP
All EnviroStart DIP Switches are polled continuously and it should be possible to make
changes whilst the unit is running to change between operational modes. It is however good
practice to make changes whilst the unit is switched off to ensure that the software is not
“hung” or “corrupted” as a result of a spike being transmitted to the chip during “live”
switching.
ADJUSTMENT
FUNCTION
DEFAULT
SETTING
RESULT
SEE SECTION
Switch 1
Energy Saving
Mode Select
OFF
Energy Savings
Enabled
4.3.3
Switch 2
Auto – Manual
Savings Select
OFF Automatic
4.3.3
Switch 3 & 4
Energy Saving
Level
ON OFF
Level 2 Energy
Savings
4.3.3
Switch 5
Soft Start
OFF
Soft Start Disabled
4.3.4
Switch 6
Two Minute Time
Delay
OFF
Time Not Enabled
4.3.5