Firmware Upgrades
The XtremeDV-SDI4 cards allow
firmware
upgrades to be completed on site rather than returning the
card to EMS. Whenever a
firmware
upgrade is performed, the SW2 on the DIP switch must be set ON.
The DIP Switch can be located on the back of the XtremeDV-SDI4 (See Fig. 6 ). To perform the upgrade,
follow the step-by-step instructions provided by the upgrade application. The XtremeDV-SDI4 is shipped
with the SW2
SWITCH
set at ON, therefore no action should be necessary.
In the unlikely event that something goes wrong during the upgrade process (e.g. System power outage) it
is possible to revert to the factory settings by powering down the system, temporarily setting SW2 to the
OFF position then powering up the system. Once the system has rebooted, set the SW2 back to the ON
position (while the system is still powered up) and restart the
firmware
upgrade process.
It should be noted that the latest driver installation program includes an automatic firmware update, if
required. Therefore, prior to installing the application and driver, ensure that SW2 is set to ON.