9
DirectShow
If you change the link ordering after installation you must run dplinks.exe. This program will update the
existing input names used by the windows DirectShow interface.
To run the dplinks program open the
Run
by clicking on
Start/Run
and type dplinks and then press Enter.
The program will run, however no notifications are displayed.
Firmware Upgrades
The XtremeAV-HD1+ cards allow
firmware
upgrade to be completed on site rather than returning the
card to Datapath. Whenever a
firmware
upgrade is performed, the J11 Link
MUST BE FITTED on the
XtremeAV-HD1+. To perform the upgrade, follow the step-by-step instructions provided by the upgrade
application.
In the unlikely event that something goes wrong during the upgrade process (e.g. System power outage)
it is possible to revert to the factory settings by powering down the system, temporarily removing the J11
link then powering up the system with the link removed. Once the system has rebooted, replace the J11
link (whilst the system is powered up) and restart the
firmware
upgrade process.
It should be noted that the latest driver installation program includes an automatic
firmware
update, if
required. Therefore, prior to installing the application and driver, ensure that J11 link is
fitted.
Software Installation
Software Installation
The Xtreme software (driver and application) is installed from www.ems-imaging.com
The installation process should start automatically.
Follow the installation wizard instructions as prompted.
Regular software updates are available from our website:
www.ems-imaging.com