SAFETY
EMPYRE ELITE XT INSTALLATION AND OPERATION MANUAL
7
Front View
Rear View
Red
White
Probe-
2 wire
black
cable
Probe
Power
7 8
10 11
Com NO
White
Red
1
2
3
4
3
5
1
4
7
8
6
2
10
9
Red
Wiring Diagram
818492 - R0
Limit Switch - 815822
1.
Blower Switch - 800836
2.
Indicater Light - 806481
3.
Timer Unit - 817482
4.
Temp Controller A - 810268
5.
Probe Well - 806455
6.
Snap Disc - 816271
7.
Blower - 814185
8.
Furnace Power Cord
9.
Probe - 812424
10.
Black
Orange
1
White
Orange
Yellow
Blue
Blue
Blue
Yellow
Purple
White
Red
Orange
Ground
}
110 volts
AC 60Hz
Black power line
White neutral line
NO NC
2
DANGER
!
Risk of fire or explosion.
DO NOT
start or fuel the fire using
garbage, gasoline, drain oil or other flammable liquids or
chemicals.
WARNING
!
SAFE DOOR OPERATION:
OUTER DOOR
Always keep outer door closed and latched during normal
operation. When door is open always secure door with
door stop rod.
LOADING DOOR: ALWAYS OPEN SLOWLY
1. Move
LEVER
above loading door to the left, timer
comes on, wait momentarily and
SLOWLY
open
loading door. Timer will shut down the furnace after
5 minutes. To reset timer, move lever to the right and
then back to the left. Lever in the right position puts
the furnace into the normal running mode, timer is
then locked out.
2. After loading
CLOSE
and
LATCH
door firmly and move
LEVER
to the right.
DO NOT
operate with loading door open.
ASH REMOVAL DOOR: ALWAYS OPEN SLOWLY
1.
ALWAYS
switch furnace off before opening door.
DO NOT
operate with ash removal door open.
2.
CLOSE
and
LATCH
door firmly.
- For safety keep firebox loading door and ash door
tightly closed.
- Follow listed combustibles installation clearances.
- DO NOT store fuel or other combustible materials within
the marked installation clearances of the furnace.
- Inspect and clean flues and chimney regularly.
- Follow complete installation, operating and cleaning
instructions in the Operator’s Manual.
CAUTION
!
-
Hot
surfaces do not touch.
-
KEEP CHILDREN
at safe distance.
-
DO NOT
damage furnace. Load wood carefully.
-
DO NOT
add fuel during a power outage.
-
KEEP
water level above the add mark.
- Place ash in metal containers and away from
combustible materials.
817970R00
SPECIFICATIONS
Install and use only in accordance
with the manufacturer’s installation/
operating instructions and local
codes. If there are no applicable local
codes, an outdoor installation chimney
must be listed to the ULC-S610 and
ULC-S604 standard and an indoor
installation must follow ANSI/NFPA
211 and NFPA90B. Chimney must
be a listed UL 103 HT or ULC S629
residential all-fuel type or tile-lined
masonry. Flue connector pipe must
be made of a minimum 24 NSG black
steel. Special precautions are required
for passing the chimney through a
combustible wall or ceiling. Refer
to authorities having jurisdiction for
proper installation.
Minimum Clearance to Combustibles
Side Wall to Furnace
12” (305 mm)
Back Wall to Furnace 12” (305 mm)
Front of Furnace to
Combustibles
48” (1220 mm)
Combustibles to Flue 12” (305 mm)
Ceiling to Furnace
24” (610 mm)
Floor*
0” (0 mm)
CAUTION
!
-
DO NOT
connect the unit to a
chimney flue that serves another
appliance.
-
DO NOT
burn trash in this furnace.
-
DO NOT
pressurize water in
furnace.
-
DO NOT
dump ash close to any
combustible materials.
- The heat exchanger, flue pipe,
chimney must be in good condition
and cleaned regularly to remove
accumulated creosote and ash.
- Clean at the end of the heating
season to minimize corrosion
during summer months.
- Follow cleaning instructions in
Operator’s Manual.
- Refer to Operator’s Manual for
complete instructions.
In the event of loss of electrical power:
1. Open all check and zone valves in
the system. Depending on system
design, this may allow convective
circulation.
2. It is important to remember that
the heating system cannot dispose
of a great deal of heat without the
circulators running. Avoid over firing!
DO NOT LOAD LARGE AMOUNTS OF
SOLID FUEL INTO THE FURNACE!
Fire the furnace cautiously until you
are able to determine how quickly
the heat system is able to dissipate
the heat being produced by the
furnace.
3. When the power has returned,
reset all check and zone valves and
resume normal operation of the
system.
In the event of a runaway fire:
1. Ensure the firebox door is tightly
closed.
2. Close all the combustion air inlets
on the furnace.
To cool an overheated furnace:
1. Turn all thermostats to their highest
temperature setting.
817971R00
* For indoor installation a noncombustible
liner must be placed under the furnace.
1.
3.
4.
5.
7.
6.
2.
EMPYRE ELITE XT HYDRONIC FURNACE
15
Empyre Elite XT 100/200 #702112231 or #70626288
Empyre Elite XT 100/200 no 702112231 ou no 70626288
817978R00
Model No./Certifién de Modèle
□
100
□
200
Serial No./ N° de Série
___________________________
Certified Heating Appliance CSA Standard B366.1-M91 UL Standard 391-2006/726-06 Standard C22.2 No. 3
Appareil de Chauffage Norme B366.1-M91 de la CSA Norme 391 de ULC - 2006/726-06 Norme C22.2 No 3
EMPYRE ELITE XT - FOURNAISE HYDRONIQUE Á BRÛLAGE PROPRE
WN20717
WARNING
!
ELECTROCUTION HAZARD
ALWAYS SECURE DOOR WITH LATCH.
TIGHTEN WITH WRENCH.
815541
Front View
Rear View
1
2
3
7
6
5
4