background image

SAFETY

EMPYRE ELITE XT INSTALLATION AND OPERATION MANUAL 

7

Front View

Rear View

Red

White

Probe- 

2 wire 

black 

cable

Probe

Power

7 8

10 11

Com NO

White

Red

1

2

3

4

3

5

1

4

7

8

6

2

10

9

Red

Wiring Diagram

         818492 - R0

 

Limit Switch - 815822

1.

Blower Switch - 800836

2.

Indicater Light - 806481

3.

Timer Unit - 817482

4.

Temp Controller A - 810268

5.

Probe Well - 806455

6.

Snap Disc - 816271

7.

Blower - 814185

8.

Furnace Power Cord

9.

Probe - 812424

10.

Black

Orange

1

White

Orange

Yellow

Blue

Blue

Blue

Yellow

Purple

White

Red

Orange

Ground

}

110 volts 

AC 60Hz

Black power line

White neutral line

NO NC

2

DANGER

!

Risk of fire or explosion.

 DO NOT

 start or fuel the fire using 

garbage, gasoline, drain oil or other flammable liquids or 

chemicals.

WARNING

!

SAFE DOOR OPERATION:

OUTER DOOR

Always keep outer door closed and latched during normal 

operation.  When  door  is  open  always  secure  door  with 

door stop rod.

LOADING DOOR: ALWAYS OPEN SLOWLY

1.  Move 

LEVER

  above  loading  door  to  the  left,  timer 

comes  on,  wait  momentarily  and 

SLOWLY

  open 

loading door. Timer will shut down the furnace after 

5 minutes. To reset timer, move lever to the right and 

then back to the left. Lever in the right position puts 

the  furnace  into  the  normal  running  mode,  timer  is 

then locked out.

2.   After  loading 

CLOSE

  and

 LATCH

  door  firmly  and  move 

LEVER

 to the right. 

DO NOT 

operate with loading door open.

ASH REMOVAL DOOR: ALWAYS OPEN SLOWLY

1. 

ALWAYS

 switch furnace off before opening door.  

DO NOT

 operate with ash removal door open.

2. 

CLOSE

 and 

LATCH

 door firmly.

-  For  safety  keep  firebox  loading  door  and  ash  door  

tightly closed.

-  Follow listed combustibles installation clearances.

-  DO NOT store fuel or other combustible materials within 

the marked installation clearances of the furnace.

-  Inspect and clean flues and chimney regularly.

-  Follow  complete  installation,  operating  and  cleaning 

instructions in the Operator’s Manual.

CAUTION

!

-

  Hot

 surfaces do not touch. 

KEEP CHILDREN

 at safe distance.

DO NOT

 damage furnace. Load wood carefully.

DO NOT

 add fuel during a power outage.

KEEP

 water level above the add mark.

-  Place  ash  in  metal  containers  and  away  from 

combustible materials.

817970R00

SPECIFICATIONS

Install and use only in accordance 

with the manufacturer’s installation/

operating instructions and local 

codes. If there are no applicable local 

codes, an outdoor installation chimney 

must be listed to the ULC-S610 and 

ULC-S604 standard and an indoor 

installation must follow ANSI/NFPA 

211 and NFPA90B. Chimney must 

be a listed UL 103 HT or ULC S629 

residential all-fuel type or tile-lined 

masonry. Flue connector pipe must 

be made of a minimum 24 NSG black 

steel. Special precautions are required 

for passing the chimney through a 

combustible wall or ceiling. Refer 

to authorities having jurisdiction for 

proper installation.

Minimum Clearance to Combustibles

Side Wall to Furnace

12” (305 mm)

Back Wall to Furnace 12” (305 mm)
Front of Furnace to 

Combustibles

48” (1220 mm)

Combustibles to Flue 12” (305 mm)
Ceiling to Furnace

24” (610 mm)

Floor*

0” (0 mm)

CAUTION

!

DO NOT

 connect the unit to a 

chimney  flue  that  serves  another 

appliance.

DO NOT

 burn trash in this furnace.

DO NOT

 pressurize water in 

furnace.

DO NOT

 dump ash close to any 

combustible materials.

-  The  heat  exchanger,  flue  pipe, 

chimney must be in good condition 

and cleaned regularly to remove 

accumulated creosote and ash.

-  Clean at the end of the heating 

season to minimize corrosion 

during summer months.

-  Follow cleaning instructions in 

Operator’s Manual.

-  Refer to Operator’s Manual for 

complete instructions.

In the event of loss of electrical power:

1.  Open all check and zone valves in 

the system. Depending on system 

design, this may allow convective 

circulation.

2.  It is important to remember that 

the heating system cannot dispose 

of a great deal of heat without the 

circulators running. Avoid over firing! 

DO NOT LOAD LARGE AMOUNTS OF 

SOLID FUEL INTO THE FURNACE!

 

Fire the furnace cautiously until you 

are able to determine how quickly 

the heat system is able to dissipate 

the heat being produced by the 

furnace.

3.  When the power has returned, 

reset all check and zone valves and 

resume normal operation of the 

system.

In the event of a runaway fire:

1.  Ensure  the  firebox  door  is  tightly 

closed.

2.  Close all the combustion air inlets 

on the furnace.

To cool an overheated furnace: 

1.  Turn all thermostats to their highest 

temperature setting.

817971R00

* For indoor installation a noncombustible 

liner must be placed under the furnace.

1.

3.

4.

5.

7.

6.

2.

EMPYRE ELITE XT HYDRONIC FURNACE

15

Empyre Elite XT 100/200 #702112231 or #70626288

Empyre Elite XT 100/200 no 702112231 ou no 70626288

817978R00

Model No./Certifién de Modèle  

 

100  

 

200 

Serial No./ N° de Série

 ___________________________

Certified Heating Appliance   CSA Standard B366.1-M91   UL Standard 391-2006/726-06   Standard C22.2 No. 3

Appareil de Chauffage   Norme B366.1-M91 de la CSA   Norme 391 de ULC - 2006/726-06   Norme C22.2 No 3

EMPYRE ELITE XT - FOURNAISE HYDRONIQUE Á BRÛLAGE PROPRE

WN20717 

WARNING

!

ELECTROCUTION HAZARD

ALWAYS SECURE DOOR WITH LATCH. 

TIGHTEN WITH WRENCH.

815541

Front View

Rear View

1

2

3

7

6

5

4

Содержание Elite XT 100

Страница 1: ...Installation and Operation Instructions Empyre Elite XT Model 100 and 200...

Страница 2: ......

Страница 3: ...Foundation Dimensions 11 Trench for Underground Pipes 11 Outdoor Furnace Installation 12 Outdoor Chimney Installation 12 Indoor Chimney Installation 12 Supplying Make Up Air 12 Low Water Temperature P...

Страница 4: ...Heating Season 21 Reference 22 27 Operating the Digital Temperature Switch DTS 22 Hot Water Wood Furnace Wiring Diagram 23 How to Correct a Sticking Flapper 24 Furnace Specifications 25 Unit Dimensio...

Страница 5: ...e Empyre Elite XT Works The Empyre Elite XT uses a process called wood gasification to produce highly efficient combustion in the furnace s dual burn chambers 1 Wood in the firebox burns from the bott...

Страница 6: ..._________ Serial No _______________________________ EMPYRE ELITE XT HYDRONIC FURNACE 15 Empyre Elite XT 100 200 702112231 or 70626288 Empyre Elite XT 100 200 no 702112231 ou no 70626288 817978R00 Mode...

Страница 7: ...running mode timer is then locked out 2 After loading CLOSE and LATCH door firmly and move LEVER to the right DO NOT operate with loading door open ASH REMOVAL DOOR ALWAYS OPEN SLOWLY 1 ALWAYS switch...

Страница 8: ...ally hazardous situation that if not avoided MAY result in minor or moderate injury if proper practices are not taken or serves as a reminder to follow appropriate safety practices Safety Decals Pleas...

Страница 9: ...PA 211 and NFPA90B Chimney must be a listed UL 103 HT or ULC S629 residential all fuel type or tile lined masonry Flue connector pipe must be made of a minimum 24 NSG black steel Special precautions a...

Страница 10: ...or Panel 13 Secondary Burn Chamber 13 A Brick Configuration No Description 13 B Insulation Board Configuration 14 Ash Tray 15 Smoke Deflector Angle 16 Latch Catch Locking Bolt Front Rear Door 17 Latch...

Страница 11: ...39 Electric Element Ports 40 Flue Cleaning Tool 41 Drain 42 Rear Lower Cover No Description 43 Right Side Panel 44 Supply Port 1 Elite XT 100 1 1 4 Elite XT 200 45 Flue Clean Out Cover 46 Probe Shiel...

Страница 12: ...rovided that a noncombustible liner such as sheet metal or masonry be placed on the floor ensuring the following areas are covered to catch stray embers Underneath the furnace At least 16 406 mm in fr...

Страница 13: ...to determine the line size necessary to meet the demands of your specific application 4 Identify each water line clearly in order to correctly locate the supply and return lines 5 Lay down 14 2 under...

Страница 14: ...Sections of stove pipe minimum 24 gauge black or blued steel may be used from the furnace to the insulated chimney Note avoid using 90 Elbows 45 is recommended A chimney cap must be installed Lining m...

Страница 15: ...T requires an automatic protection from low water tem perature because of the manual fuel feed Condensation water in the boiler tubes will cause corro sion and premature failure The ESO as installed i...

Страница 16: ...r Line Hookup See Figures 1 to 3 Important Pump must always be in lowest part of the water line system from the Empyre Elite XT to the building Pump may be at the furnace or in the building Note The s...

Страница 17: ...ill serve your needs and conforms to all local provinicial state and national codes The Pro Fab Industries warranty covers the Empyre Elite XT furnace only and does not include anything outside of the...

Страница 18: ...through vent opening Figure 1 9 Check water level when water temperature is 170 F 77 C and add water until level indicator shows full Maintaining Proper Water Level When the water level is low the Em...

Страница 19: ...wood when possible When using the recommended seasoned wood where the moisture content is between 19 and 25 the diameter of the wood is not that important Scenario 1 is also created when stirring a h...

Страница 20: ...out ash tray 4 Reach the ash rake to the back of the chamber and pull ash forward into the ash tray Do not scrape all of the ash into the ash tray It is recommended to leave 1 2 2 5 5 1 cm of ash cov...

Страница 21: ...nace WILL NOT operate To maintain optimal performance 1 Do not leave loading door open for extended periods of time especially when the fire is very hot 2 Do not force the loading door open beyond the...

Страница 22: ...y A buildup in the flues and chimney will cause a poor draft and reduce efficiency 6 Check and clean the air passages in the upper loading door frame several times during the heating season To clean t...

Страница 23: ...proper amount of water treatment is in the system In the event that there has been water loss through the season additional water treatment will need to be added Follow the treatment ratio on the bott...

Страница 24: ...ircuit probe error Open probe error DTS Technical Data Accuracy 1 Output 16 Amp 1HP 240 Vac SPDT relay Supply voltage 115 Vac 10 Display 3 digit red DTS Programming Press SET SP text will appear on th...

Страница 25: ...range 1 White Orange Yellow Blue Blue Blue Yellow Purple White Red Orange Ground 110 volts AC 60Hz Black power line White neutral line NO NC 2 CAUTION DO NOT CONNECT THE ELECTRICAL COMPONENTS OF THIS...

Страница 26: ...ist 1 Check if furnace is being operated properly 2 Remove flapper unit check to ensure the flap seals in the closed position clean and oil How to Remove and Reinstall 1 Disconnect power 2 Remove blow...

Страница 27: ...15 cm 6 in 15 cm Log Length 24 in 61 cm 25 in 64 cm Log Diameter 6 in 15 cm 6 in 15 cm Furnace Weight excluding pallet 1 050 lb 476 kg 1 635 lb 742 kg Water Capacity 60 US Gal 227 L 112 US Gal 424 L N...

Страница 28: ...569 9 61 81 335 2 13 20 852 5 33 56 1484 5 58 45 Elite 100 Unit Dimensions 3 1 4 1 2 Not shown 0 817753 Revisions DESCRIPTION ECO Production Release 2535 REV Figure 2 Brick Layout Figure 3 Refractory...

Страница 29: ...10 03 11 Production Release 816632 ECO Empyre Elite Asse 816632 81663 Revisions M D Y REV 2 4 3 2 2 2 2 4 2 2 2 4 2 2 2 2 2 2 2 2 2 2 1 1 DP APP 2745 BY 0 DESCRIPTION 10 03 11 Production Release 81663...

Страница 30: ...s air passage in the firebox floor is blocked by charcoal ash Using the ash rake always stir the firebox charcoal ash into the lower ash chamber before adding wood Limit the charcoal ash buildup and l...

Страница 31: ......

Страница 32: ...y Registration and a copy of the original bill invoice must be forwarded to Pro Fab within thirty 30 days of the date of purchase to validate the warranty Issue Date May 2012 Part No 817969R00 Printed...

Отзывы: