Figure 5 (SR-10T)

Figure 6 (SR-18T)

SR-30T Clearances (Figure 4)
When facing the front of the appliance the following minimum clearances
to combustible construction must be maintained.

Left side 8 inches (203mm). Right side 8 inches (203mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Minimum vertical clearance from a projection above the appliance
(shelves, window sills, etc.) 36 inches (914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).

Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing and proper
operation must be provided.

Figure 4 (SR-30T)

Locating Gas Supply
The gas line can be routed either through the floor  or wall.  The gas line
opening should be made at this time.  Location of the opening will be
determined by the position of floor joists and the valve and union used
for servicing.

Wall Mount Installation (Figures 5, 6 and 7)
Refer to Figures 5, 6 and 7 for measurements in order to locate (4)
mounting holes on wall.  Figures 5, 6 and 7 are the front views of the
heaters.

1. Remove lower louver from casing assembly (2 screws).
2. Remove reflector from casing assembly (2 screws).
3. Remove upper louver from casing assembly (2 screws).

36" (914mm) MIN

8"

(203mm)

MIN

8"

(203mm)

MIN

2"

(51mm)

 MIN

7 13/16"

(198mm)

11 13/16"

(300mm)

1 3/32"

(28mm)

18 7/8"

(479mm)

22"

(559mm)

4 1/32"

(102mm)

2"MIN (51mm)

2"

(51)

2"

(51)

18"

(457mm)

2"

(51)

14"

(356mm)

2"

(51)

1 3/32

(28mm)

18 7/8"

(479mm)

22"

(559mm)

2" (51mm)

2 1/32 (52mm)

4 1/32"

(102mm) MIN

Содержание SR-10T-2

Страница 1: ...ified installer service agency or the gas supplier INSTALLATION INSTRUCTIONS AND OWNER S MANUAL UNVENTED ROOM HEATER MODELS SR 10T 2 SR 18T 2 SR 30T 2 EFFECTIVE DATE MARCH 2000 This is an unvented gas fired heater It uses air oxygen from the room in which itisinstalled Provisionsforadequatecom bustion and ventilation air must be pro vided Refer to page 4 WARNING Ifnotinstalled operatedand maintain...

Страница 2: ...esignedtoturnofftheheaterifnotenoughfresh air is available DO NOT TAMPER WITH PILOT LIGHT SAFETY SYSTEM If heater shuts off do not relight until you provide fresh air If heater keeps shutting off have it serviced Keep burner and control compartment clean CARBON MONOXIDE POISONING MAY LEAD TO DEATH Early signs of carbon monoxide poisoning resemble the flu with headache dizziness and or nausea If yo...

Страница 3: ...b or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gasmaystratifyinaclosedarea andtheodorintensitycould vary at different levels Since it is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas odor If you detect any odor treat it as a serious l...

Страница 4: ...a problem In most applications the water vapor enhances the low humidity atmosphere experienced during cold weather The following steps will help insure that water vapor does not become a problem 1 Be sure the heater is sized properly for the application including ample combustion air and circulation air 2 If high humidity is experienced a dehumidifier may be used to help lower the water vapor con...

Страница 5: ...Whenfacingthefrontoftheappliancethefollowingminimumclearances to combustible construction must be maintained Left side 6 inches 152mm Right side 6 inches 152mm Do not install in alcove or closet Rear wall 0 inches 0mm Ceiling 24 inches 610mm Minimum vertical clearance from a projection above the appliance shelves window sills etc 14 inches 356mm Maximum horizontal extension of projection above the...

Страница 6: ...SR 30T Locating Gas Supply The gas line can be routed either through the floor or wall The gas line opening should be made at this time Location of the opening will be determined by the position of floor joists and the valve and union used for servicing Wall Mount Installation Figures 5 6 and 7 Refer to Figures 5 6 and 7 for measurements in order to locate 4 mounting holes on wall Figures 5 6 and ...

Страница 7: ...ing steps to properly align the upper louver and the reflector with the heat shield a When replacing upper louver be sure the bottom lip of upper louver goes behind the heat shield b When replacing reflector be sure the top lip of reflector goes in front of the heat shield 3 Connect the gas line On Sheet Rock Wall 1 After locating mounting holes drill 4 5 16 8mm diameter holes into the wall 2 Inse...

Страница 8: ...P T plugged tapping High Altitudes For altitudes elevations above 2 000 feet 610m ratings should be reduced at the rate of 4 percent for each 1 000 feet 305m above sea level Contact the manufacturer or your gas company before changing spud orifice size Piezo Pilot Ignitor Instructions Depressing the ignitor button completely causes a spark to occur at the pilot To light the pilot it is important t...

Страница 9: ... assembly 1 Turn OFF gas supply to the heater 2 Turn OFF electric supply to the heater if optional blower is installed in heater 3 Remove lower louver from casing assembly 2 screws 4 Remove reflector from casing assembly 2 screws 5 Inspect interior of casing assembly for accumulation of dust lint or spider webs If necessary clean interior of casing assembly with a vacuumcleanerorapplyairpressure D...

Страница 10: ...laques will glow There will never be a time when only one or two ceramic plaques are glowing The SR 30T has an input of 30 000 BTUH 8 8KW H The hydraulic thermostat bulb is located at the casing assembly bottom When the hydraulic thermostat bulb senses the need for heat the unit cycles ON at a full input rate of 30 000 BTUH 8 8KW H The unit remains at this full input rate until the hydraulic therm...

Страница 11: ... 1 minute after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 4 through 8 If knob does not pop up when released stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 9 Attention GascontrolhasanIN...

Страница 12: ...clean see Main Burner Flame Page 9 Attention Thenumberstampedonthemain burner orifice is a millimeter diameter b Inlet gas pressure too low contact gas supplier 5 Heater keeps shutting OFF during normal operation a Pilot is blocked clean pilot see Page 9 b Inlet gas pressure too low contact gas supplier TROUBLESHOOTING INFORMATION FOR QUALIFIED SERVICE PERSON SYMPTOMS POSSIBLE CAUSES AND CORRECTIO...

Страница 13: ... HARDWARE PACKAGE SR 30T 1 10811 CASING SIDE ASSEMBLY LEFT 2 SR 041 CASING BACK 3 R 2313 PIEZO IGNITOR 4 SR 008 CASING SIDE ASSEMBLY RIGHT 5 SR 113 VALVE BRACKET 6 R 2351 GAS VALVE SIT 7 R 2329 BURNER 8 SR 114 ORIFICE SHIELD 9 SR 032 PILOT BRACKET 10 R 5007 PILOT THERMOCOUPLE ASSEMBLY NAT ONLY INCLUDES ITEM 11 10 R 5001 PILOT THERMOCOUPLE ASSEMBLY LPG ONLY INCLUDES ITEM 11 11 R 5003 THERMOCOUPLE L...

Страница 14: ...Page 14 R 5210 SR 10T ...

Страница 15: ...R 5210 Page 15 SR 18T ...

Страница 16: ...Page 16 R 5210 SR 30T ...

Страница 17: ...iththeheaterstandingupright positiontheairdischargeopening of the blower housing downward Place the bottom flange of the blower housing over the top edge of the top heat shield Insert the blower housing into the top portion of the heater by pivoting the blower housing upward 90 Attach the blower housing to the casing assembly with 4 screws provided with the optional blower 13 Grasp cord set at cas...

Страница 18: ...eration after servicing Blower Motor The blower motor does not have oiling holes Do not attempt to oil the blower motor Blower Wheel The blower wheel will collect lint and could require periodic cleaning If the air output decreases or the noise level increases it indicates a dirty blower wheel To clean blower wheel 1 Turn OFF gas supply to the heater 2 Turn OFF electrical supply to the heater 3 Re...

Отзывы: