SR-30T Clearances (Figure 4)
When facing the front of the appliance the following minimum clearances
to combustible construction must be maintained.
Left side 8 inches (203mm). Right side 8 inches (203mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Minimum vertical clearance from a projection above the appliance
(shelves, window sills, etc.) 36 inches (914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and proper
operation must be provided.
Figure 4 (SR-30T)
Locating Gas Supply
The gas line can be routed either through the floor or wall. The gas line
opening should be made at this time. Location of the opening will be
determined by the position of floor joists and the valve and union used
for servicing.
Wall Mount Installation (Figures 5, 6 and 7)
Refer to Figures 5, 6 and 7 for measurements in order to locate (4)
mounting holes on wall. Figures 5, 6 and 7 are the front views of the
heaters.
1. Remove lower louver from casing assembly (2 screws).
2. Remove reflector from casing assembly (2 screws).
3. Remove upper louver from casing assembly (2 screws).
36" (914mm) MIN
8"
(203mm)
MIN
8"
(203mm)
MIN
2"
(51mm)
MIN
7 13/16"
(198mm)
11 13/16"
(300mm)
1 3/32"
(28mm)
18 7/8"
(479mm)
22"
(559mm)
4 1/32"
(102mm)
2"MIN (51mm)
2"
(51)
2"
(51)
18"
(457mm)
2"
(51)
14"
(356mm)
2"
(51)
1 3/32
(28mm)
18 7/8"
(479mm)
22"
(559mm)
2" (51mm)
2 1/32 (52mm)
4 1/32"
(102mm) MIN
Содержание SR-10T-2
Страница 14: ...Page 14 R 5210 SR 10T ...
Страница 15: ...R 5210 Page 15 SR 18T ...
Страница 16: ...Page 16 R 5210 SR 30T ...