35008-1-0515
Page 12
pLANNING INSTALLATION
•
Within a partial enclosure which includes an overhead cover
and three sidewalls, as long as 30% or more of the horizontal
periphery (i.e. perimeter) of the enclosures is permanently
open; such as an open porch. See Figure 7.
FIREPLACE
Figure 7
ATTENTION: Vinyl Soffit, Vinyl Ceiling, Vinyl Overhang
Disclaimer
Clearances are to heat resistant material (i.e. wood, metal). This
does not include vinyl. Empire Comfort Systems Inc. will not be
held responsible for heat damage caused from terminating under
vinyl overhangs, vinyl ceilings or vinyl ventilated/unventilated
soffits.
WARNING
Improper installation, adjustment, alteration, service or mainte-
nance can cause property damage, personal injury or loss of life.
Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
Gas Line Connection
The fireplace is designed to accept a 1/2 in. gas line. Have the
line installed by a qualified service person in accordance with all
building codes. Consult local building codes to properly size the gas
supply line leading to the 1/2 in. hook-up at the unit. The state of
Massachusetts requires that a flexible fireplace connector cannot
exceed three feet in length.
A flex-line connection to the valves is provided.
The gas shut-off
valve must be located outside of the unit in an accessible area.
Check gas type on the rating label located on the back of the control
door. If the gas listed on the rating label located on the control panel,
does not match your gas supply, DO NOT INSTALL. Contact your
dealer for proper model or conversion kit.
Always use an external regulator for all LP fireplaces to reduce the
supply tank pressure to a maximum of 13 in. w.c.
WARNING
Connection directly to an unregulated L.P. tank can cause an
explosion.
WARNING
Risk of fire, explosion or asphyxiation. Ensure no ignition, flame
or spark are near during installation. This includes cigarettes or
cell phones.
Leak test all connections with a soap and water solution. Bubble
formation will indicate a leak. Use caution to avoid burns.
Figure 8
Water Drainage Requirement
Provisions must be made to drain water away from the unit. An
optional drain pan can be purchased from your Empire Dealer to
fit under the fireplace. If installing the optional drain pan, it must
be installed prior to installing the fireplace. For more information,
refer to the installation instructions supplied with the drain pan. If
this drain is not used, other water drainage is required.