background image

35008-1-0515

Page 12

pLANNING INSTALLATION

• 

Within a partial enclosure which includes an overhead cover 

and three sidewalls, as long as 30% or more of the horizontal 

periphery (i.e. perimeter) of the enclosures is permanently 

open; such as an open porch. See Figure 7.

FIREPLACE

Figure 7

ATTENTION: Vinyl Soffit, Vinyl Ceiling, Vinyl Overhang 

Disclaimer

Clearances are to heat resistant material (i.e. wood, metal). This 

does not include vinyl. Empire Comfort Systems Inc. will not be 

held responsible for heat damage caused from terminating under 

vinyl overhangs, vinyl ceilings or vinyl ventilated/unventilated 

soffits.

 

WARNING

Improper installation, adjustment, alteration, service or mainte-

nance can cause property damage, personal injury or loss of life. 

Installation and service must be performed by a qualified installer, 

service agency or the gas supplier.

Gas Line Connection

The fireplace is designed to accept a 1/2 in. gas line. Have the 

line installed by a qualified service person in accordance with all 

building codes. Consult local building codes to properly size the gas 

supply line leading to the 1/2 in. hook-up at the unit. The state of 

Massachusetts requires that a flexible fireplace connector cannot 

exceed three feet in length.

A flex-line connection to the valves is provided. 

The gas shut-off 

valve must be located outside of the unit in an accessible area.

Check gas type on the rating label located on the back of the control 

door. If the gas listed on the rating label located on the control panel, 

does not match your gas supply, DO NOT INSTALL. Contact your 

dealer for proper model or conversion kit.

Always use an external regulator for all LP fireplaces to reduce the 

supply tank pressure to a maximum of 13 in. w.c. 

 

WARNING

Connection directly to an unregulated L.P. tank can cause an 

explosion.

 

WARNING

Risk of fire, explosion or asphyxiation. Ensure no ignition, flame 

or spark are near during installation. This includes cigarettes or 

cell phones.

Leak test all connections with a soap and water solution. Bubble 

formation will indicate a leak. Use caution to avoid burns. 

Figure 8

Water Drainage Requirement

Provisions must be made to drain water away from the unit. An 

optional drain pan can be purchased from your Empire Dealer to 

fit under the fireplace. If installing the optional drain pan, it must 

be installed prior to installing the fireplace. For more information, 

refer to the installation instructions supplied with the drain pan. If 

this drain is not used, other water drainage is required.

Содержание OLL60FP12SN-1

Страница 1: ...DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space such as a camper te...

Страница 2: ...nance See page 27 Tools Needed 1 1 8 inch Allen Wrench 2 Adjustalbe wrenches with range of 1 inch for gas connection 2 Adjustable pipe wrenches 1 Phillips Screwdriver CARTON CONTENTS INDEX NO DESCRIPT...

Страница 3: ...PLACE INSTALLATION FRAMING INSTALLATION 14 15 ELECTRICAL SUPPLY 16 GAS SUPPLY 17 LP GAS CYLINDER INFORMATION 18 19 FINISHING 20 22 LIGHTING INSTRUCTIONS 23 MAIN BURNER FLAME CHARACTERISTICS 24 OPERATI...

Страница 4: ...Please leave these instructions with the owner for future reference This unit complies with ANSI Z21 97 CSA 2 41 for Outdoor Gas Fireplaces InstallationandrepairshouldbedonebyaQUALIFIEDSERVICE PERSON...

Страница 5: ...as can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clos...

Страница 6: ...Topaz Clear DG1AB 1 2 in Decorative Glass Droplets Aqua Blue DG1GC 1 2 in Decorative Glass Droplets Glacier Ice DG1SL 1 2 in Decorative Glass Droplets Sangria Luster Note Decorative Glass Droplets ma...

Страница 7: ...e changing spud orifice size Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail registration card supplied...

Страница 8: ...19 3 16 21 5 8 24 10 Figure 2 Mantel Clearances Do not attach combustible material to the mantel of your fireplace This is a fire hazard Figure 1 COMBUSTIBLE MATERIALS No greeting cards stockings or o...

Страница 9: ...replace opening 16 in of non combustible material is provided to allow for placement of wall joint in a cooler temperature zone NON COMBUSTIBLE WALL BOARD PROVIDED Framing Header Fireplace Opening 2 1...

Страница 10: ...The width of the firebox opening 60 60 F The interior depth of the firebox not shown 19 23 7 8 G The rear exterior width of the firebox not shown 60 60 K Height from the bottom of the box to the gas l...

Страница 11: ...NOTICE This fireplace is NOT equipped with an Oxygen Depletion Sensor ODS pilot Installation of the fireplace may be in an open area however it is recommended that this fireplace be installed in an a...

Страница 12: ...equires that a flexible fireplace connector cannot exceed three feet in length A flex line connection to the valves is provided The gas shut off valve must be located outside of the unit in an accessi...

Страница 13: ...with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 Latest Edition A factory installed junction box is located on the lower right side of the fireplace The...

Страница 14: ...eplace Framing Before completing the framing and installing fireplace provide a path for water drainage out of the fireplace Determine if the optional accessory drain pan will be used See Page 12 If t...

Страница 15: ...f the control panel with a Phillips head screw driver See Figure 15 Figure 15 d Lift front of burner assembly and tilt upwards and toward the back of the fireplace Retrieve the two supports from insid...

Страница 16: ...use A connector for the junction box to accommodate 1 2 in conduit is supplied in the instruction envelope The fireplace receptacle must be connected to an external GFI protected outlet installed nea...

Страница 17: ...ct your local authorized installer for installation or relocation Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases The gas lines must be ch...

Страница 18: ...en achieved It is also equipped with an excess flow device In order to attain full flow to the fireplace the valve must be in the off position when the cylinder valve is turned on WARNING A fire will...

Страница 19: ...r surface of the floor of the LP gas supply cylinder enclosure and the ground Cylinder valves shall be readily accessible for hand opera tion A door on the enclosure to gain access to the cylinder val...

Страница 20: ...d in step 7 on page 15 and reinstall the control door and center pivot pin 4 Unscrew the ignitor button and install the AA battery provided in the instruction envelope prior to closing the control doo...

Страница 21: ...with screws into the frame and pre drill and counter sink 1 8 in diameter holes into the fireplace face Finish remain ing wall with weather proof wallboard Note Areas where the steel has been formed c...

Страница 22: ...een and burner enough media to cover approximately 10 square feet Ensure coverage is even and not thicker in places Some pieces of broken glass may be larger than others It is fine to use these pieces...

Страница 23: ...cover s must be removed before use Remove any debris including leaves and insects from the burner area and the bed of crushed glass 1 Before turning on the main gas supply press the ignitor button Ver...

Страница 24: ...urs with the burner at the highest setting Any odors remaining after this initial break in will disappear with continued use Flames from the main burner should be visually out before the weather door...

Страница 25: ...hen not in use LED Mode Button Press the Mode Button to adjust LED light system from Automatic Color Changes to Individual Colors 1 Auto cycle Rapid 2 Auto cycle Gradual 3 Pause Auto cycle 4 Deep Blue...

Страница 26: ...oper and dangerous operation Verify proper operation after servicing WIRING YELLOW RED BLACK BLACK BLACK RED BLACK LED STRIP LED STRIP TRANSFORMER CONTROL MODULE BLACK BLACK BLACK R11931 LEFT BUTTON B...

Страница 27: ...n abrasive stainless steel cleaner immediately WARNING Do not use Ammonia based or abrasive cleaners on glass Do not attempt to clean glass when glass is hot PERIODIC CLEANING Refer to parts diagram f...

Страница 28: ...n and or replace thermocouple 6 Burner does not stay lit a Burnerorificeclogged Cleanburnerorreplacemainburner orifice b Inlet gas pressure is too low Contact qualified service person 7 If burning at...

Страница 29: ...be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number an...

Страница 30: ...SEMBLY SUPPLY 1 1 20 P271 FITTING ORIFICE 1 1 21 R10808 AIR SHUTTER STAINLESS 1 1 22 P279 ORIFICE 14 1 0 22 P256 ORIFICE 41 0 1 23 B101848 GAS CONTROL KNOB 1 1 24 R7195 CONNECTOR BRASS MALE 1 1 25 R11...

Страница 31: ...35008 1 0515 Page 31 OLL60FP PARTS VIEW 5 4 5 17 16 14 15 4 27 26 25 24 23 19 10 10 12 21 20 18 3 7 8 9 6 28 29 22 30 32 31 11 1 34 35 35 37 38 36 13 2 39 33 33...

Страница 32: ...20 P271 FITTING ORIFICE 1 1 21 R10808 AIR SHUTTER STAINLESS 1 1 22 P279 ORIFICE 14 1 0 22 P256 ORIFICE 41 0 1 23 B101848 GAS CONTROL KNOB 1 1 24 R7195 BRASS CONNECTOR MALE 1 1 25 R11916 VALVE LP MANU...

Страница 33: ...35008 1 0515 Page 33 OLL60SP PARTS VIEW 27 26 25 24 23 19 10 10 12 21 20 2 3 5 7 8 9 4 28 29 22 4 40 30 2 5 4 17 16 14 15 3 6 32 31 34 35 35 33 11 34 4 18 1 37 38 13 36 39 33...

Страница 34: ...35008 1 0515 Page 34 Fireplace SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 35: ...A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might...

Страница 36: ...t Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact...

Отзывы: