Empire OLI-24-2 Скачать руководство пользователя страница 7

37139-8-1219

Page 7

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment  

or accessories and repair and servicing of equipment shall be 

performed only by a  qualified agency.  The term "qualified agency" 

means any individual, firm, corporation or company which either in 

person or through a representative is engaged in and is responsible for 

(a) the installation or replacement of gas piping or (b) the connection, 

installation, repair or servicing of equipment, who is experienced in 

such work, familiar with all precautions required and has complied 

with all the requirements of the authority having jurisdiction.

Commonwealth of Massachusetts:

 The installation must be 

made by a licensed plumber or gas fitter in the Commonwealth 

of Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental 

room heaters shall provide to each purchaser a copy of 527 CMR 

30 upon sale of the unit.
In the Commonwealth of Massachusetts, unvented propane and 

natural gas-fired space heaters shall be prohibited in bedrooms 

and bathrooms.

The installation must conform with local codes or, in the 

absence of local codes, with the National Fuel Gas Code, ANSI 

Z223.1.*

*Available from the American National Standards Institute, Inc.  1430 

Broadway, New York, N.Y. 10018.

High Altitudes

For altitudes/elevations above 2,000 feet (610m), ratings should be 

reduced at the rate of 4 percent for each 1,000 feet (305m) above 

sea level. Contact the manufacturer or your gas company before 

changing spud/orifice size.
• 

When the appliance is connected to a fixed piping system, 

the installation must conform with ocal codes, or in the ab-

sence of local codes with the 

National Fuel Gas Code, ANSI 

Z223.1/NFPA 54

, or 

International Fuel Gas Code

.

• 

When installed, the appliance must be electrically grounded 

in accordance with local codes, or in the absence of local 

codes with the 

National Electrical Code, ANSI/NFPA 70

, if 

applicable.

• 

Solid fuels shall not be burned in this appliance.

• 

The maximum gas inlet supply pressure is 13" for Propane 

and 10.5" for Natural.

• 

For appliances for fixed fuel piping system and equipped 

with an appliance gas pressure regulator, the required mani-

fold pressure in inches water column: 10" for Propane and 

3.5" Natural.

• 

For appliances for fixed fuel piping system and equipped 

with an appliance gas pressure regulator, the appliance and 

its individual shut-off valve must be disconnected from the 

gas supply piping system during any pressure testing of that 

system at test pressures in excess of 1/2 psi (3.5 kPa). 

The appliance must be isolated from the gas supply piping 

system by closing its individual manual shut-off valve during 

any pressure testing of the gas supply piping system at test 

pressures equal to or less than 1/2 psi (3.5 kPa).

For an appliance designed for use with a non-disposable self-

contained Propane Gas supply system:

• 

Propane cylinders may be acceptable for use with the ap-

pliance provided they are are compatible with the appliance 

retention means. 

• 

Propane Gas supply cylinder must be constructed and 

marked in accordance with the 

U.S. Department of Transpor-

tation (D.O.T.) Specifications for Propane Gas Cylinders

, or 

the 

Standard for Cylinders, Spheres and Tubes for Trans-

portation of Dangerous Goods and Commission, CAN/CSA-

B339

 as applicable. 

• 

Propane Gas supply cylinder must have an overfill preven

-

tion device.

• 

Propane Gas supply cylinder must have a connection device 

compatible with the connection of the appliance.

• 

If the appliance is equipped with a CGA No. 600 Cylinder 

Connection Device, the cylinder must be disconnected when 

the appliance is not in use.

• 

If appliance is to be permanently connected to a gas piping 

system from a remote supply tank, installation must be in ac-

cordance with local codes or, in the absence of local codes, 

with the 

National Fuel Gas Codes ANSI Z223.1/NFPA 54.

Enclosures for Propane Gas supply cylinders shall be ventilated 

by openings at the level of the cylinder valve and at floor level. 

The effectiveness of the opening(s) for purposes of ventilation 

shall be determined with the Propane Gas supply cylinder(s) in 

place. This shall be accomplished by one of the following.

a.  One side of the enclosure shall be completely open; or
b.  For an enclosure having four sides, a top and a bottom:

1.  At least two ventilation openings at cylinder valve 

level shall be provided in the side wall, equally 

sized, spaced at 180 degrees (3.14rad), and unob

-

structed. Each opening shall have a total free area 

of not less than 1/2 square inch per pound (2.3 sq. 

cm/kg) of stored fuel capacity and not less than a 

total free area of 10 square inches (64.5 sq. cm).

INTRODUCTION

Содержание OLI-24-2

Страница 1: ...xtinguish any open flame 3 If odor continues leave the area immediately 4 After leaving the area call your gas supplier or fire department Failure to follow these instructions could result in fire or...

Страница 2: ...port cylinder where it would be exposed to high temperatures Relief valve may open allowing a large amount of flammable gas to escape When transporting keep cylinder secured in an upright position wit...

Страница 3: ...ecifications 9 Before Fully Installing the Appliance 9 Gas Supply 10 Operation Instructions Flame Appearance 11 OLI 24 30 Lighting Instructions 12 Main Burner Flame Characteristics 13 Cleaning and Ser...

Страница 4: ...ENTS Model 1 Index Number Description Quantity Supplied 1 AA Battery 4 2 Burner Assembly 1 3 Battery Pack 1 4 Remote Control w Battery 1 5 Hardware Pack 1 CARTON CONTENTS HARDWARE PACK CONTENTS Descri...

Страница 5: ...rform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of Propane Gas Odor fade due to oxidation by rust or adsorption on...

Страница 6: ...burning fireplace This appliance is only for use with the type of gas indicated on the rating plate Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2...

Страница 7: ...and 3 5 Natural For appliances for fixed fuel piping system and equipped with an appliance gas pressure regulator the appliance and its individual shut off valve must be disconnected from the gas supp...

Страница 8: ...kg of stored fuel capacity and not less than a total free area of 10 square inches 64 5 sq cm If ventila tion openings at floor level are in a side alll there shall be at least two openings The botto...

Страница 9: ...15 9 16 34 5 16 24 3 16 OLI 30 32 15 9 16 38 5 16 24 3 16 The dimensions shown and defined in the fireplace instructions are minimum clearances to maintain in installing this heater Left and right cle...

Страница 10: ...uld consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect The use of the following gas connectors is...

Страница 11: ...grate Inspect and clean burner air intake hole Remove lint or particles with brush Failure to keep air intake hole clean will result in sooting and poor combustion ANNUAL CLEANING INSPECTION Refer to...

Страница 12: ...NCE 1 Locate On Off gas shut off and turn clockwise to OFF Do not force OLI 24 30 Lighting Instructions LIGHTING INSTRUCTIONS 1 STOP Read the safety information above 2 Turn gas shut off counterclockw...

Страница 13: ...high grade stainless steel to resist rust through In outdoor applications all stainless steel will develop a dull patina and depending on the local environment and on the materials used in the install...

Страница 14: ...use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the module to accept the transmitter security code be sure the slide button on t...

Страница 15: ...4 P245 P265 Orifice Propane 4 P209 P209 Orifice Natural 5 R10808 R10808 Air Shutter 6 28739 28740 Burner with Bracket 7 R10814 R10814 Spark Probe 8 28089 28089 Valve Shield 9 R10810 R10810 Gas Valve P...

Страница 16: ...37139 8 1219 Page 16 FIREPLACE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 17: ...37139 8 1219 Page 17 FIREPLACE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 18: ...se and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model...

Страница 19: ...cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from the...

Страница 20: ...ww empirecomfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question plea...

Отзывы: