Empire OLI-24-2 Скачать руководство пользователя страница 14

37139-8-1219

Page 14

TWO-FUNCTION WIRELESS REMOTE CONTROL SySTEM

FOR ON/OFF-HI/LO OPERATION OF THE AF-4000 GAS CONTROL VALVE

IF yOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT 

ATTEMPT TO OPERATE

INTRODUCTION

This remote control system was developed to provide a safe, reliable, and user-friendly remote control system for use with the AF-4000 

gas control valve used with some gas heating appliances. The system operates on radio frequencies (RF) within a 20’ range using non-

directional signals. The system operates on one of 255 security codes that are programmed into the transmitter at the factory; the remote 

receiver must learn the transmitter code prior to initial use.

TRANSMITTER

This remote control TRANSMITTER offers the user a battery-operated hand held control to operate the AF-4000 control module functions 

that are used with some decorative gas fireplaces and other gas heating appliances.

The transmitter operates with a 12V battery (Included) made specifically for remote controls 

and electronic lighters. Before using the transmitter, install the 12-volt (A-23) battery in the 

battery compartment. 

It is recommended that ALKALINE batteries always be used for longer battery life and maxi

-

mum operational performance.

The transmitter has ON/OFF and HI/LO functions that are activated by pressing the button 

on the face of the transmitter. When a button on the transmitter is pressed, a signal light on 

the transmitter illuminates to verify that a signal is being sent. Upon initial use, there may be 

a delay of three seconds before the remote receiver will respond to the transmitter. This is 

part of the system’s design. If the signal light does not illuminate, check the position of the 

transmitter’s battery.

MATCHING SECURITy CODES

Each transmitter can use one of 255 unique security codes. It may be necessary to program 

(LEARN FUNCTION) the module to accept the transmitter security code upon initial use, if batteries are replaced, or if a replacement 

transmitter is purchased from your dealer or the factory. In order for the module to accept the transmitter security code, be sure the slide 

button on the module is in the REMOTE position; the module will NOT “LEARN” if the slide switch is in the OFF position. Press and re

-

lease the LEARN button on the module to accept the transmitter security code and then pressing any button on the transmitter. A change 

in the beeping pattern, at the module, indicates the transmitter’s code has been accepted into the module. When an existing module has 

accepted the new transmitter code, the new security code will replace the old one.

The microprocessor that controls the security code matching procedure is controlled by a timing function. If you are unsuccessful in 

matching the security code on the first attempt, wait 1 - 2 minutes before trying again - this delay allows the microprocessor to reset its 

timer circuitry - and try up to two or three more times.

OPERATION

1.  This remote control will operate the AF-4000 gas control valves ON/OFF and flame height HI/LO of the main burner.

2.  When the ON button is depressed the transmitter sends a RF signal to the module. The module then sends 3 volts of power to the 

internal solenoid. The internal solenoid then opens the gas flow to the main burner ON/OFF. The system uses a pulse or continuous 

3 volts DC power to operate the flame HI/LO solenoid or flame HI/LOW DC motor drive.

BATTERy LIFE

Life expectancy of the alkaline batteries in the RCAF-3 TX can be up to 12 months depending on use of the solenoid function. Check and 

replace all batteries annually. The transmitter should operate with as little as 9.0 volts battery power.

SPECIFICATIONS

BATTERIES: 

Transmitter 12V - (A23)

Operating Frequency:  303.8 MHZ 

FCC ID No.’s: transmitter K9l1001

 

Canadian ISC ID No.’s: transmitter - 2439 102 728

FCC REQUIREMENTS

NOTICE:

 

The manufacturer is not responsible for any radio or tv interference caused by unauthorized modifications to this equipment. 

Such modifications could void the user’s authority to operate the equipment.

REMOTE CONTROL INSTALLATION & OPERATION

Содержание OLI-24-2

Страница 1: ...xtinguish any open flame 3 If odor continues leave the area immediately 4 After leaving the area call your gas supplier or fire department Failure to follow these instructions could result in fire or...

Страница 2: ...port cylinder where it would be exposed to high temperatures Relief valve may open allowing a large amount of flammable gas to escape When transporting keep cylinder secured in an upright position wit...

Страница 3: ...ecifications 9 Before Fully Installing the Appliance 9 Gas Supply 10 Operation Instructions Flame Appearance 11 OLI 24 30 Lighting Instructions 12 Main Burner Flame Characteristics 13 Cleaning and Ser...

Страница 4: ...ENTS Model 1 Index Number Description Quantity Supplied 1 AA Battery 4 2 Burner Assembly 1 3 Battery Pack 1 4 Remote Control w Battery 1 5 Hardware Pack 1 CARTON CONTENTS HARDWARE PACK CONTENTS Descri...

Страница 5: ...rform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of Propane Gas Odor fade due to oxidation by rust or adsorption on...

Страница 6: ...burning fireplace This appliance is only for use with the type of gas indicated on the rating plate Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2...

Страница 7: ...and 3 5 Natural For appliances for fixed fuel piping system and equipped with an appliance gas pressure regulator the appliance and its individual shut off valve must be disconnected from the gas supp...

Страница 8: ...kg of stored fuel capacity and not less than a total free area of 10 square inches 64 5 sq cm If ventila tion openings at floor level are in a side alll there shall be at least two openings The botto...

Страница 9: ...15 9 16 34 5 16 24 3 16 OLI 30 32 15 9 16 38 5 16 24 3 16 The dimensions shown and defined in the fireplace instructions are minimum clearances to maintain in installing this heater Left and right cle...

Страница 10: ...uld consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect The use of the following gas connectors is...

Страница 11: ...grate Inspect and clean burner air intake hole Remove lint or particles with brush Failure to keep air intake hole clean will result in sooting and poor combustion ANNUAL CLEANING INSPECTION Refer to...

Страница 12: ...NCE 1 Locate On Off gas shut off and turn clockwise to OFF Do not force OLI 24 30 Lighting Instructions LIGHTING INSTRUCTIONS 1 STOP Read the safety information above 2 Turn gas shut off counterclockw...

Страница 13: ...high grade stainless steel to resist rust through In outdoor applications all stainless steel will develop a dull patina and depending on the local environment and on the materials used in the install...

Страница 14: ...use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory In order for the module to accept the transmitter security code be sure the slide button on t...

Страница 15: ...4 P245 P265 Orifice Propane 4 P209 P209 Orifice Natural 5 R10808 R10808 Air Shutter 6 28739 28740 Burner with Bracket 7 R10814 R10814 Spark Probe 8 28089 28089 Valve Shield 9 R10810 R10810 Gas Valve P...

Страница 16: ...37139 8 1219 Page 16 FIREPLACE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 17: ...37139 8 1219 Page 17 FIREPLACE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 18: ...se and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model...

Страница 19: ...cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from the...

Страница 20: ...ww empirecomfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question plea...

Отзывы: