29432-2-1013
Page 19
TROUBLESHOOTING LCD FAULT CODES ON THE DISPLAY PANEL
FAULT
DESCRIPTION
LCD Digits
Description
ACTION
Anomaly as parasit-
ic flame, APT failure
or APS failure
Desired flame
level is shown
Yellow LED permanently OFF
Turn off main power to the fire
-
place for 30 minutes. If problem
persists, contact a qualified
service person
Green and red LED blink slowly and simultaneously
Ignition lock-out
“A1”
Yellow LED permanently OFF
Check for gas presence.
Reset fireplace and retry ignition
sequence. If problem persists
contact a qualified service
person
Red LED permanently ON
Green LED performs 1 blink followed by a 1s pause
High water level
fault
“A2”
Yellow LED permanently OFF
Contact a qualified service
person
Red LED permanently ON
Green LED performs 2 blinks followed by a 1s pause
Transducer fault
“A3”
Yellow LED permanently OFF
Check air pressure switch and
air pressure transducer hose
connections. Reset fireplace
and retry ignition. If problem
persists, contact a qualified
service person.
Red LED permanently ON
Green LED performs 2 blinks followed by a 1s pause
Pressure switch
fault
“A4”
Yellow LED permanently OFF
Check air pressure switch and
air pressure transducer hose
connections. Reset fireplace
and retry ignition. If problem
persists, contact a qualified
service person.
Red LED permanently ON
Green LED performs 4 blinks followed by a 1s pause
Overheat lock-out
“A5”
Yellow LED permanently OFF
Allow fireplace to cool com
-
pletely then reset fireplace.
If problem persists, contact a
qualified service person.
Red LED permanently ON
Green LED performs 5 blinks followed by a 1s pause
Thermistor failure
“A6”
Yellow LED permanently OFF
Contact a qualified service
person.
Red LED permanently ON
Green LED performs 6 blinks followed by a 1s pause
Inadequate
Combustion Airflow
“A7”
Yellow LED permanently OFF
Contact a qualified service
person.
Red LED permanently ON
Green LED performs 7 blinks followed by a 3s pause
Thermistor temp too
high
“A0”
Yellow LED permanently OFF
Allow fireplace to cool com
-
pletely then reset fireplace.
If problem persists, contact a
qualified service person.
Red LED permanently ON
Green LED performs 1 blink followed by a 3s pause