Empire FAW40IPXLP-1 Скачать руководство пользователя страница 16

37134-4-0319

Page 16

uSE oNlY MANuFAcTurEr'S rEPlAcEMENT PArTS.  uSE oF ANY oTHEr PArTS coulD cAuSE INjurY or DEATH.

PlEASE NoTE:  

When ordering parts, it is very important that 

part number

 and 

description

 of part coincide.

INDEX 

No.

PArT 

No.

DEScrIPTIoN

1

WFA115

GASKET - hEADER

2

DV1247

TOP PLATE (USA)

2

15668

TOP PLATE (cANADA)

3

R3165

DOOR CLIP (2 REQUIRED)

4

39476

cASING SIDE - RIGhT

5

DV1203

cASING BAcK

6

39476

cASING SIDE - LEFT

7

DV1248

AIR DROP (INcLuDES NO. 51)

8

DV1231

TURBULATOR (3 REQUIRED)

9

DV1250

DIVIDER PLATE

10

DV1234

OUTLET BOX

11

DV1225

OUTLET BOX COVER

12

R3177

VENT SAFETY SWITch

13

R3161

FAN BLADE

14

R3166

FAN MOTOR

15

DV1246

MOTOR MOuNTING BRAcKET

16

R1536

BuShING (5 REQuIRED)

17

R1499

RUBBER GROMMET (4 REQUIRED)

18

R1454

BRASS BuShING (4 REQuIRED)

19

R3164

DOOR CLIP (2 REQUIRED)

20

DV1251

INNER ShIELD - RIGhT 

(INcLuDES NO. 23)

21

R6176

FAN cONTROL SWITch

22

R3176

LIMIT SWITCH

23

DV1253

INNER ShIELD cOVER PLATE 

(2 REQUIRED)

24

DV1254

INNER ShIELD FRONT (SPP)

24

33416

INNER ShIELD FRONT (IP)

25

R3163

FILTER RETAINER

26

R3162

FILTER

27

DV1252

INNER ShIELD -LEFT 

(INcLuDES NO. 23)

28

DV1256

EXchANGER ASSEMBLY

29

DV1235

PILOT BRACKET (IP)

30

R3232

PILOT - NATuRAL (IP)

30

R3233

PILOT - PROPANE (IP)

31

P8851

ORIFIcE - NATuRAL (3 REQUIRED)

31

P8860

ORIFIcE - PROPANE (3 REQUIRED)

32

DV1236

MANIFOLD

33

DV1258

cASING FRONT

34

P112

MANIFOLD uNION

35

R1109

BuShING (3/8 x 1/2)

35

R9502

BuShING (3/8 x 3/4) - NATuRAL (IP)

36

R5655

GAS VALVE - PROPANE (SPP)

36

R2148

GAS VALVE - NATuRAL (SPP)

36

R3170

GAS VALVE - NATuRAL (IP)

36

R3171

GAS VALVE - PROPANE (IP)

37

R2708

PIEZO IGNITOR (SPP)

38

FF160

PIEZO BRACKET (SPP)

39

DV1318

OBSERVATION hOLE cOVER PLATE

40

DV1242

BuRNER cOMPARTMENT FRONT 

(SPP)

41

DV1237

BuRNER cOMPARTMENT BODY 

42

M148

MANIFOLD GASKET

43

GWT168 AIR ShuTTER FRONT (PROPANE)

44

GWT169 AIR SHUTTER REAR (PROPANE)

45

R3031

BuRNER (3 REQuIRED)

46

DV1239

BuRNER BRAcKET

47

UH452

TRANSFORMER MOuNTING 

BRACKET (IP)

47

UH810

TRANSFORMER MOuNTING 

BRACKET (SPP)

48

R1995

TRANSFORMER (SPP)

48

R998

TRANSFORMER (IP)

49

UH451

JuNcTION BOX cOVER

50

DV572

JuNcTION BOX

51

DV1260

cOVER PLATE - AIR DROP

52

R1410

BuShING

53

R690

CORD SET

54

R1515

BuShING

55

DV1215

BOTTOM PLATE

56

R3034

PILOT - NATuRAL (SPP)

56

R3035

PILOT - PROPANE (SPP)

57

GWT021 PILOT BRACKET (SPP)

58

R3180

ELEcTRODE AND WIRE  (SPP)

59

R2256

ThERMOcOuPLE -18" (SPP)

N/S

DV1261

PILOT TuBING W/FERRuLES

N/S

R1081

PILOT ORIFIcE - NATuRAL (SPP)

N/S

R1089

PILOT ORIFIcE - PROPANE (SPP)

N/S

R1233

PILOT ORIFIcE - NATuRAL (IP)

N/S

R3265

PILOT ORIFIcE - PROPANE (IP)

N/S

R3172

WIRE hARNESS (SPP)

N/S

R3173

WIRE hARNESS (IP)

N/S

R1587C

VENT SAFETY WIRE ASSEMBLY

N/S - NOT ShOWN

INDEX 

No.

PArT 

No.

DEScrIPTIoN

Содержание FAW40IPXLP-1

Страница 1: ...operty damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try t...

Страница 2: ...d Tile If this appliance is installed directly on carpeting tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full wid...

Страница 3: ...inal venting system may no longer be sized to properly vent the attached appliances Instructions shall also indicate effects of an improperly sized venting system formation of condensate leakage spill...

Страница 4: ...can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity Propane Gas may stratify in a cl...

Страница 5: ...n in a Confined Space A confined space is an area with volume less than 50 cubic feet per 1 000 Btuh of the combined input rates of all appliances drawing combustion air from that space Small areas su...

Страница 6: ...in a horizontal distance of 10 feet 3m 2 This furnace must not be connected to a chimney flue serving a separate solid fuel burning appliance 3 UninsulatedSingle WallMetalPipeshallnotbeusedoutdoors in...

Страница 7: ...ide outlet wall plate over outer boot pass the outer boot through the wall and attach side wall plate to furnace side of wall with 2 10 x 1 1 2 38mm provided screws 5 Attach outer boot to the cabinet...

Страница 8: ...ehind the furnace Attach furnace to wall at the outer casing top with 2 toggle bolts provided and to floor at the outer casing bottom with 2 10 x 1 1 2 38mm screws provided Gas Supply Check all local...

Страница 9: ...cover screw on the control valve Figure 9 and turn the adjustment screw clockwise to reduce flame Replace pilot cover screw to eliminate gas leakage Propane Gas will not require adjustment After use...

Страница 10: ...located on the draft diverter 3 Replace front panel If the manual reset vent safety switch continues to shut off the gas flow to the main burners a qualified service person must be contacted to inspe...

Страница 11: ...he same terminal it was on Terminal should have a light spark Do not short across terminals as it will burn out the GAS CONTROL 2 To check for line voltage to furnace remove front panel and short acro...

Страница 12: ...rn off all electric power to the appliance 3 Remove control access panel front panel 4 Turn gas control knob clockwise to OFF GAS CONTROL SHOWN IN OFF POSITION 5 Wait ten 10 minutes to clear out any g...

Страница 13: ...iance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance Do not touch any e...

Страница 14: ...ition OFF Wait for Flame Signal to Disappear Pilot Valve Closes Ignition OFF Main Pilot Valves Close Flame Lost More Than 5 Times in One Call for Heat 5 Minute Retry Delay 3 Second Flame Recycle Delay...

Страница 15: ...Flowing Wait to Assure Pilot Gas Tubing is Purged Measure Voltage Between 24V Hot and 24V Common Leads to SmartValve Control Must Measure at Least 19 5 VAC with Igniter Powered See Inset A to Identif...

Страница 16: ...31 P8851 ORIFICE Natural 3 REQUIRED 31 P8860 ORIFICE Propane 3 REQUIRED 32 DV1236 MANIFOLD 33 DV1258 CASING FRONT 34 P112 MANIFOLD UNION 35 R1109 BUSHING 3 8 x 1 2 35 R9502 BUSHING 3 8 x 3 4 NATURAL I...

Страница 17: ...37134 4 0319 Page 17...

Страница 18: ...ase and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Mode...

Страница 19: ...le cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from t...

Страница 20: ...ww empirecomfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question plea...