32193-3-0514
Page 10
These heating thermostats are specially designed for use on self-
generating systems. They should never be used on line or low
voltage A.C. circuits.
Exterior Wall
— The thermostat may be mounted on an exterior
wall above the heater if it is located in the same stud space as
the vent tubes and is a minimum of 6" (152mm) above the heater.
Interior Wall
— The thermostat should be installed on an inside
wall away from the unit but in the same room.
Note:
Use 16 gauge wire to prevent excessive loss of millivolts.
Proper operation depends on a good pilot flame. The flame must
cover the top of the thermopile. Cleaning of the pilot orifice and
burner may be required due to spiders.
System Check
A millivolt meter is required to check the system. The millivolt
readings should be:
• Across the thermopile terminals, 400-450 millivolts with thermostat
OFF.
• Across the thermopile terminals, 150-250 millivolts with thermostat
ON.
• Across the thermostat wires at the valve, less than 30 millivolts
with thermostat ON.
• Across the thermostat wires at the thermostat, less than 5 millivolts
with thermostat ON. (Strong winds, dirty pilot and low pressure
will reduce readings.)
OPTIONAL THERMOSTAT LOCATION
Piezo Pilot Ignitor Instructions
Depressing the piezo ignitor button completely causes a spark to
occur at the pilot. This is a substitute for a match which requires
opening the pilot hole cover.
To light the pilot, it is important that the electrode be 1/8" (3mm)
from the thermopile. The spark must occur at the point the burner
flame hits the thermopile. The end of the electrode will be red hot
with the pilot on.
On a new installation with air in the gas line, it is suggested that a
match be used. The match will light the pilot faster than the piezo
under this condition.
To Conserve Gas: Turn off pilot when heater is not in use.
Figure 6
Содержание DV-210-10SG
Страница 15: ...32193 3 0514 Page 15 PARTS VIEW...
Страница 34: ...32193 3 0514 Page 14 VUE DES PI CES...
Страница 51: ...32193 3 0514 Page 15 VISTA DE PARTES...
Страница 53: ...32193 3 0514 Page 17 NOTAS DE SERVICIO T CNICO...
Страница 54: ...32193 3 0514 Page 18 NOTAS DE SERVICIO T CNICO...
Страница 55: ...32193 3 0514 Page 19 NOTAS DE SERVICIO T CNICO...