SAFETY INFORMATION FOR USERS OF LP-GAS

Some people cannot smell well. Some people cannot smell the 

odor of the chemical put into the gas. You must find out if you can 

smell the odorant in propane. Smoking can decrease your ability 

to smell. Being around an odor for a time can affect your sensitivity 

or ability to detect that odor. Sometimes other odors in the area 

mask the gas odor. People may not smell the gas odor or their 

minds are on something else. Thinking about smelling a gas odor 

can make it easier to smell.
The odorant in LP-gas is colorless, and it can fade under some 

circumstances. For example, if there is an underground leak, the 

movement of the gas through soil can filter the odorant. Odorants 

in LP-Gas also are subject to oxidation. This fading can occur if 

there is rust inside the storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or into walls, 

masonry and other materials and fabrics in a room. That will take 

some of the odorant out of the gas, reducing its odor intensity.
LP-Gas may stratify in a closed area, and the odor intensity could 

vary at different levels. Since it is heavier than air, there may be 

more odor at lower levels. Always be sensitive to the slightest gas 

odor. If you detect any odor, treat it as a serious leak. Immediately 

go into action as instructed earlier.

Propane (LP-Gas) is a flammable gas which can cause fires and 

explosions. In its natural state, propane is odorless and colorless. 

You may not know all the following safety precautions which can 

protect both you and your family from an accident. Read them 

carefully now, then review them point by point with the members 

of your household. Someday when there may not be a minute to 

lose, everyone's safety will depend on knowing exactly what to do. 

If, after reading the following information, you feel you still need 

more information, please contact your gas supplier.

• 

Learn to recognize the odor of LP-gas. 

Your local LP-Gas 

Dealer can give you a "Scratch and Sniff" pamphlet. Use it to 

find out what the propane odor smells like. If you suspect that 

your LP-Gas has a weak or abnormal odor, call your LP-Gas 

Dealer.

• 

If you are not qualified, do not light pilot lights, perform service, 

or make adjustments to appliances on the LP-Gas system. If 

you are qualified, consciously think about the odor of LP-Gas 

prior to and while lighting pilot lights or performing service or 

making adjustments.

•  Sometimes a basement or a closed-up house has a musty 

smell that can cover up the LP-Gas odor. Do not try to light 

pilot lights, perform service, or make adjustments in an area 

where the conditions are such that you may not detect the 

odor if there has been a leak of LP-Gas.

• 

Odor fade, due to oxidation by rust or adsorption on walls of 

new cylinders and tanks, is possible. Therefore, people should 

be particularly alert and careful when new tanks or cylinders 

are placed in service. Odor fade can occur in new tanks, or 

reinstalled old tanks, if they are filled and allowed to set too 

long before refilling. Cylinders and tanks which have been 

out of service for a time may develop internal rust which will 

cause odor fade. If such conditions are suspected to exist, 

a periodic sniff test of the gas is advisable. If you have any 

question about the gas odor, call your LP-gas dealer. A periodic 

sniff test of the LP-gas is a good safety measure under any 

condition.

• 

If, at any time, you do not smell the LP-Gas odorant and you 

think you should, assume you have a leak. Then take the same 

immediate action recommended above for the occasion when 

you do detect the odorized LP-Gas.

• 

If you experience a complete "gas out," (the container is un-

der no vapor pressure), turn the tank valve off immediately. 

If the container valve is left on, the container may draw in 

some air through openings such as pilot light orifices. If this 

occurs, some new internal rusting could occur. If the valve is 

left open, then treat the container as a new tank. Always be 

sure your container is under vapor pressure by turning it off 

at the container before it goes completely empty or having it 

refilled before it is completely empty.

•  Do not operate electric switches, light matches, use your 

phone. Do not do anything that could ignite the gas.

•   Get everyone out of the building, vehicle, trailer, or area. Do 

that IMMEDIATELY.

•   Close all gas tank or cylinder supply valves.
•   LP-Gas is heavier than air and may settle in low areas such 

as basements. When you have reason to suspect a gas leak, 

keep out of basements and other low areas. Stay out until 

firefighters declare them to be safe.

•   Use your neighbor's phone and call a trained LP-Gas service 

person and the fire department. Even though you may not 

continue to smell gas, do not turn on the gas again. Do not 

re-enter the building, vehicle, trailer, or area.

•   Finally, let the service man and firefighters check for escaped 

gas. Have them air out the area before you return. Properly 

trained LP-Gas service people should repair the leak, then 

check and relight the gas appliance for you.

SOME POINTS TO REMEMBER

NO ODOR DETECTED - ODOR FADE

LP-GAS WARNING ODOR

If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas. 

That's your signal to go into immediate action!

Содержание BF-10BC-2

Страница 1: ...ier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in this manual is not followed exactly a...

Страница 2: ...ilation Air 6 Gas Supply 7 Clearances 8 Wall Mount Installation 8 9 Optional Floor Stand Installation 9 Lighting Instructions 10 Main Burner Flame Characteristics 11 Pilot Flame Characteristics 12 The...

Страница 3: ...d free from combustible materials gasoline and other flammable vapors and liquids WARNING ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS Any safety screen or guard removed for servicing an...

Страница 4: ...the LP Gas odor Do not try to light pilot lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor...

Страница 5: ...d servicing of equipment shall be performed only by a qualified agency The term qualified agency means any individual firm corporation or company that either in person or through a representative is e...

Страница 6: ...ate of all appliances in the space The following example is for determining the volume of a typical area in which the BF 20 may be located and for determining if this area fits the definition of an un...

Страница 7: ...liance Connectors of Corrugated MetalTubing and Fittings ANSZ21 45AssembledFlexibleApplianceConnectorsofOther Than All Metal Construction The above connectors may be used if acceptable by the authorit...

Страница 8: ...heater 1 Remove lower louver from casing assembly 2 screws 2 Remove reflector from casing assembly 2 screws 3 Remove upper louver from casing assembly 2 screws On Solid Wall 1 Afterlocatingmountingho...

Страница 9: ...protection is for rugs that are extremely thick and light colored tile Figure 6 On Sheet Rock Wall 1 After locating mounting holes drill 4 5 16 8mm diameter holes into the wall 2 Insert 4 plastic expa...

Страница 10: ...as Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you don t smell gas go to the next step 6 Find pilot the pilot is attached at the botto...

Страница 11: ...ir shutter on main burner is factory set at a 3 32 opening If yellow flames occur on main burner loosen 1 4 screw on air shutter in order to increase air shutter opening The slot on air shutter allows...

Страница 12: ...t of 10 000 BTU HR 2 9 KW H The hydraulic thermostat bulb is located at the casing assembly bottom BF 20 The gas control modulates from a minimum input of 8 500 BTU HR 2 5 KW H LO setting to a maximum...

Страница 13: ...gas leaks at all gas connections before lower louver is replaced onto casing assembly To Remove Gas Valve From Casing Assembly 1 Turn OFF gas supply to the heater 2 Turn OFF electrical supply to the...

Страница 14: ...T position not completely depressed or held in long enough b INTERLOCK latching device is operative see Lighting Instructions Page 10 Step 9 c Thermocouple lead not tightened into gas control tighten...

Страница 15: ...1 10460 BURNER BRACKET LEFT 22 10422 BURNER 23 10424 AIR SHUTTER BF 10 ONLY 24 10461 BURNER BRACKET RIGHT 25 P 214 MAIN BURNER ORIFICE BF 10 NAT 25 P 193 MAIN BURNER ORIFICE BF 10 LPG 25 P 252 MAIN BU...

Страница 16: ...16013 6 0314 Page 16 PARTS VIEW...

Страница 17: ...rew provided with the optional blower 12 With the heater standing upright position the air discharge opening of the blower housing downward Place the bottom flange of the blower housing over the top e...

Страница 18: ...oil the blower motor Blower Wheel The blower wheel will collect lint and could require periodic cleaning If the air output decreases or the noise level increases it indicates a dirty blower wheel To c...

Страница 19: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Страница 20: ...rols Thermostats Accessories and Parts Should any remote control thermostat accessory or other part fail because of defective workmanship within one year from the date of purchase Empire will repair o...

Отзывы: