Empire BF-10BC-2 Скачать руководство пользователя страница 10

16013-6-0314

Page 10

LIGHTING INSTRUCTIONS

A.   This appliance has a pilot which must be lighted by 

hand.  When lighting the pilot, follow these instructions 

exactly.

B.   BEFORE LIGHTING  smell all around the appliance area 

for gas.  Be sure to smell next to the floor because some 

gas is heavier than air and will settle on the floor.

 

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; 

 

Do not use any phone in your building.

• 

Immediately call your gas supplier from a neighbor's 

phone.  Follow the gas supplier's instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

C.   Use only your hand to push in or turn the gas control 

knob.  Never use tools.  If the knob will not push in or 

turn by hand, don't try to repair it; call  a  qualified service 

technician.  Force or attempted repair may result in a fire 

or explosion.

D.   Do not use this appliance if any part has been under water.  

Immediately call a qualified service technician to inspect 

the appliance and to replace any part of the control system 

and any gas control which has been under water.

1.   Set thermostat (gas control knob) to lowest setting.
2.   Turn off all electric power to appliance if service is to be per-

formed (if applicable).

3.   Push in gas control knob slightly and turn clockwise  

 to "OFF".  Do not force.

1.   STOP!   Read the safety information above.
2.  Set thermostat (gas control knob) to lowest setting.
3.  Turn off all electric power to the appliance (if applicable).
4.   Push in gas control knob slightly and turn clockwise 

 

to "OFF".  Do not force.

 
5.   Wait ten (10) minutes   to clear out any gas.  Then smell for 

gas, including near the floor.  If you smell gas, STOP! Follow 

"B" in the safety information above.  If you don't smell gas, 

go to the next step.

6.   Find pilot - the pilot is attached at the 

bottom of the burner assembly.

7.   Turn gas control knob counterclock-

wise  

 to "PILOT."

8.   Push in gas control knob all the way 

and hold in.  Repeatedly push the 

piezo ignitor button until pilot is lit (or use a match to light pilot).  

Continue to hold the control knob in for about one (1) minute 

after the pilot is lit.  Release knob and it will pop back up.  Pilot 

should remain lit.  If it goes out, repeat steps 4 through 8.
•  If knob does not pop up when released, stop and im-

mediately call your service technician or gas supplier.  

• 

If the pilot will not stay lit after several tries, turn the gas 

control knob to "OFF" and call your service technician or 

gas supplier.  

9.  Attention!  Gas control has an INTERLOCK latching device.  

When the pilot is initially lit and the safety magnet is energized 

(pilot stays "ON") the INTERLOCK latching device becomes 

operative.  If the gas control is turned to the "OFF" position 

or gas flow to the appliance is shut off, the pilot cannot be 

relighted until the safety magnet is de-energized (approximately 

60 seconds).  There will be an audible "click" when the safety 

magnet in the gas control is de-energized.  Pilot can now be 

relighted.  Repeat steps 4 through 8.

10.  Turn gas control knob counterclockwise 

 to "HI". 

11.  Turn on all electric power to appliance (if applicable).
12.  Set thermostat (gas control knob) to desired setting from "HI" 

to "LO".

FOR YOUR SAFETY READ BEFORE LIGHTING

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE

WARNING:  If you do not follow these instructions exactly, a fire or explosion 

may result causing property damage, personal injury or loss of life.

Содержание BF-10BC-2

Страница 1: ...ier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in this manual is not followed exactly a...

Страница 2: ...ilation Air 6 Gas Supply 7 Clearances 8 Wall Mount Installation 8 9 Optional Floor Stand Installation 9 Lighting Instructions 10 Main Burner Flame Characteristics 11 Pilot Flame Characteristics 12 The...

Страница 3: ...d free from combustible materials gasoline and other flammable vapors and liquids WARNING ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS Any safety screen or guard removed for servicing an...

Страница 4: ...the LP Gas odor Do not try to light pilot lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor...

Страница 5: ...d servicing of equipment shall be performed only by a qualified agency The term qualified agency means any individual firm corporation or company that either in person or through a representative is e...

Страница 6: ...ate of all appliances in the space The following example is for determining the volume of a typical area in which the BF 20 may be located and for determining if this area fits the definition of an un...

Страница 7: ...liance Connectors of Corrugated MetalTubing and Fittings ANSZ21 45AssembledFlexibleApplianceConnectorsofOther Than All Metal Construction The above connectors may be used if acceptable by the authorit...

Страница 8: ...heater 1 Remove lower louver from casing assembly 2 screws 2 Remove reflector from casing assembly 2 screws 3 Remove upper louver from casing assembly 2 screws On Solid Wall 1 Afterlocatingmountingho...

Страница 9: ...protection is for rugs that are extremely thick and light colored tile Figure 6 On Sheet Rock Wall 1 After locating mounting holes drill 4 5 16 8mm diameter holes into the wall 2 Insert 4 plastic expa...

Страница 10: ...as Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you don t smell gas go to the next step 6 Find pilot the pilot is attached at the botto...

Страница 11: ...ir shutter on main burner is factory set at a 3 32 opening If yellow flames occur on main burner loosen 1 4 screw on air shutter in order to increase air shutter opening The slot on air shutter allows...

Страница 12: ...t of 10 000 BTU HR 2 9 KW H The hydraulic thermostat bulb is located at the casing assembly bottom BF 20 The gas control modulates from a minimum input of 8 500 BTU HR 2 5 KW H LO setting to a maximum...

Страница 13: ...gas leaks at all gas connections before lower louver is replaced onto casing assembly To Remove Gas Valve From Casing Assembly 1 Turn OFF gas supply to the heater 2 Turn OFF electrical supply to the...

Страница 14: ...T position not completely depressed or held in long enough b INTERLOCK latching device is operative see Lighting Instructions Page 10 Step 9 c Thermocouple lead not tightened into gas control tighten...

Страница 15: ...1 10460 BURNER BRACKET LEFT 22 10422 BURNER 23 10424 AIR SHUTTER BF 10 ONLY 24 10461 BURNER BRACKET RIGHT 25 P 214 MAIN BURNER ORIFICE BF 10 NAT 25 P 193 MAIN BURNER ORIFICE BF 10 LPG 25 P 252 MAIN BU...

Страница 16: ...16013 6 0314 Page 16 PARTS VIEW...

Страница 17: ...rew provided with the optional blower 12 With the heater standing upright position the air discharge opening of the blower housing downward Place the bottom flange of the blower housing over the top e...

Страница 18: ...oil the blower motor Blower Wheel The blower wheel will collect lint and could require periodic cleaning If the air output decreases or the noise level increases it indicates a dirty blower wheel To c...

Страница 19: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...