Empire BF-10BC-2 Скачать руководство пользователя страница 1

UNVENTED 

ROOM HEATER

MODELS

BF-10BC-2 BF-20BC-2

Unvented room heaters are for installation in SINGLE 

FAMILY TYPE RESIDENCES ONLY,  and the installation 

is limited to ONE (1) unit per residence.

Unvented room heaters are NOT TO BE USED IN BED-

ROOMS, MOBILE HOMES, TRAILERS AND RECRE-

ATIONAL VEHICLES.

Unvented room heaters are only to be used as supple-

mentary heat and NOT AS PRINCIPAL SOURCE OF 

HEAT for the room in which the unit is installed.

Unvented room heaters are not for installation in 

rooms having space which shall limit the appliance 

input to a maximum of "20 BTUH" per cubic foot of 

room space.

Unvented room heaters are NOT FOR COMMERCIAL 

OR INDUSTRIAL USE.

INSTALLATION  INSTRUCTIONS

AND

OWNER'S  MANUAL

 — Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.

 —  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do not 

use any phone in your building.

•  Immediately call your gas supplier from 

a neighbor's phone.  Follow the gas sup-

plier's instructions.

•  If you cannot reach your gas supplier, call 

the fire department. 

 —  Installation and service must be performed by 

a qualified installer, service agency or the gas 

supplier.

WARNING:  If the information in this manual is 

not followed exactly, a fire or explosion may re-

sult causing property damage, personal injury or 

loss of life.

WARNING: If not installed, operated and maintained 

in accordance with the manufacturer's instructions, 

this product could expose you to substances in fuel 

or from fuel combustion which can cause death or 

serious illness.

This is an unvented gas-fired heater. It uses air (oxy-

gen) from the room in which it is installed. Provisions 

for adequate combustion and ventilation air must be 

provided. Refer to page 6.

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM 

HEATERS

Water vapor is a by-product of gas combustion. An 

unvented room heater produces approximately one (1) 

ounce (30ml) of water for every 1,000 BTU's (.3KW's) 

of gas input per hour. Refer to page 6.

This appliance may be installed in an aftermarket, 

permanently located, manufactured (mobile) home, 

where not prohibited by local codes. 
This appliance is only for use with the type of gas 

indicated on the rating plate. This appliance is not 

convertible for use with other gases.

INSTALLER: 

Leave this manual with the appliance.

CONSUMER:  Retain this manual for future reference.

Page 1

Содержание BF-10BC-2

Страница 1: ...ier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in this manual is not followed exactly a...

Страница 2: ...ilation Air 6 Gas Supply 7 Clearances 8 Wall Mount Installation 8 9 Optional Floor Stand Installation 9 Lighting Instructions 10 Main Burner Flame Characteristics 11 Pilot Flame Characteristics 12 The...

Страница 3: ...d free from combustible materials gasoline and other flammable vapors and liquids WARNING ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS Any safety screen or guard removed for servicing an...

Страница 4: ...the LP Gas odor Do not try to light pilot lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor...

Страница 5: ...d servicing of equipment shall be performed only by a qualified agency The term qualified agency means any individual firm corporation or company that either in person or through a representative is e...

Страница 6: ...ate of all appliances in the space The following example is for determining the volume of a typical area in which the BF 20 may be located and for determining if this area fits the definition of an un...

Страница 7: ...liance Connectors of Corrugated MetalTubing and Fittings ANSZ21 45AssembledFlexibleApplianceConnectorsofOther Than All Metal Construction The above connectors may be used if acceptable by the authorit...

Страница 8: ...heater 1 Remove lower louver from casing assembly 2 screws 2 Remove reflector from casing assembly 2 screws 3 Remove upper louver from casing assembly 2 screws On Solid Wall 1 Afterlocatingmountingho...

Страница 9: ...protection is for rugs that are extremely thick and light colored tile Figure 6 On Sheet Rock Wall 1 After locating mounting holes drill 4 5 16 8mm diameter holes into the wall 2 Insert 4 plastic expa...

Страница 10: ...as Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you don t smell gas go to the next step 6 Find pilot the pilot is attached at the botto...

Страница 11: ...ir shutter on main burner is factory set at a 3 32 opening If yellow flames occur on main burner loosen 1 4 screw on air shutter in order to increase air shutter opening The slot on air shutter allows...

Страница 12: ...t of 10 000 BTU HR 2 9 KW H The hydraulic thermostat bulb is located at the casing assembly bottom BF 20 The gas control modulates from a minimum input of 8 500 BTU HR 2 5 KW H LO setting to a maximum...

Страница 13: ...gas leaks at all gas connections before lower louver is replaced onto casing assembly To Remove Gas Valve From Casing Assembly 1 Turn OFF gas supply to the heater 2 Turn OFF electrical supply to the...

Страница 14: ...T position not completely depressed or held in long enough b INTERLOCK latching device is operative see Lighting Instructions Page 10 Step 9 c Thermocouple lead not tightened into gas control tighten...

Страница 15: ...1 10460 BURNER BRACKET LEFT 22 10422 BURNER 23 10424 AIR SHUTTER BF 10 ONLY 24 10461 BURNER BRACKET RIGHT 25 P 214 MAIN BURNER ORIFICE BF 10 NAT 25 P 193 MAIN BURNER ORIFICE BF 10 LPG 25 P 252 MAIN BU...

Страница 16: ...16013 6 0314 Page 16 PARTS VIEW...

Страница 17: ...rew provided with the optional blower 12 With the heater standing upright position the air discharge opening of the blower housing downward Place the bottom flange of the blower housing over the top e...

Страница 18: ...oil the blower motor Blower Wheel The blower wheel will collect lint and could require periodic cleaning If the air output decreases or the noise level increases it indicates a dirty blower wheel To c...

Страница 19: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Страница 20: ...rols Thermostats Accessories and Parts Should any remote control thermostat accessory or other part fail because of defective workmanship within one year from the date of purchase Empire will repair o...

Отзывы: