PLEASE NOTE:  When ordering parts, it is very important that  part number and description of part coincide.
Index 

Part

  No. 

Number 

Description

  USE ONLY MANUFACTURER'S REPLACEMENT PARTS.  USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

  1 

DV-769 

Vent Cap 

  2 

DV-131 

Outside Mounting Plate 

  3 

DV-548 

Air Inlet Tube 

  4 

DV-524 

Flue Outlet Tube 

  5 

DV-757 

Vent Kit

  6 

DV-899 

Wall Mounting Bracket 

  7 

DV-900 

Inlet Air Drop Chute

  8 

DV-762  

Gasket - Air Drop Chute 

 

 

    & DV-763 

(2 Each Required) 

  9 

DV-951 

Casing Top   

  10 

DV-901 

Heat Shield

  11 

DV-902 

Inner Casing (US version)

  11 

15665 

Inner Casing (Canada version)

  12 

RH-705 

Casing Side (2 Required)

  13 

712036 

Gasket - Flue Outlet Support 

  14 

DV-903 

Combustion Chamber (DV-25)

  14 

DV-904 

Combustion Chamber (DV-35)

  15 

712098 

Gasket - Lighting Hole

  16 

DV-781 

Lighting Hole Cover Assembly 

with Clear Mica

  17 

DV-064 

Cover Plate

  18 

DV-988 

Burner (DV-25)

  18 

DV-990 

Burner (DV-35) 

  19 

672063 

Thermopile

  20 

DV-1004 

Pilot Tubing w/Ferrells

  21 

RH-238 

Burner Door

  22 

DV-778 

Gasket - Burner Door

  23 

712051 

Gasket - Pilot Burner

  24 

DV-994 

Pilot Shield

  25 

R-2224 

Pilot Burner with Orifice (Nat)

  25 

R-2223 

Pilot Burner with Orifice (LP)

  26 

DV-772 

Electrode and Wire 

  27 

DV-913 

Casing Front

  28 

742155 

Burner Orifice, (DV-25 Nat)

  28 

742238 

Burner Orifice, (DV-25 LP)

  28 

P-86-38 

Burner Orifice, (DV-35 Nat)

  28 

742233 

Burner Orifice, (DV-35 LP)

  29 

P-190 

Manifold

  30 

R-191 

Manifold Union Assembly

  31 

R-5600 

Gas Valve (Nat) 7000 MVRLC 

  31 

R-5601 

Gas Valve (LP) 7000 MVRLC 

  32 

DV-1003 

Valve Bracket

  33 

DV-764  

Gasket - Chamber Support 

 

 

  & DV-765 

(2 Each Required)

  34 

DV-908 

Valve Shield

  35 

R-2313 

Piezo Ignitor

Not Shown 

742158 

Pilot Orifice (Nat)

Not Shown 

742266 

Pilot Orifice (LP) 

Not Shown 

662021 

Wall Thermostat - Millivolt

Not Shown 

DV-885 

Hardware Package

Not Shown 

922113 

Operator Section - Nat

Not Shown 

922217 

Operator Section - LP

Not Shown 

652121 

Regulator - Nat

Not Shown 

652211 

Regulator - LP

Not Shown 

13298 

Thermostat Bracket

Index 

Part

  No. 

Number 

Description

Parts can be ordered only through your 

service person or dealer

. For best results, the

 service person or dealer 

should order parts through 

the distributor. Parts can be shipped directly to the 

service person/dealer

.

All parts listed in the

 Parts List

 have a 

Part Number

. When ordering parts, first obtain the

 Model Number

 from the name plate on your 

equipment. Then determine the Part Number (

not 

the Index Number) and the Description of each part from the following appropriate 

illustration and list. Be sure to give all this information.
Furnace Model Number 

    Part Description 

Furnace Serial Number  

  Part Number 

Type of Gas (Propane or Natural) 
Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. 
Shipments contingent upon strikes, fires and all causes beyond our control.

Empire Comfort Systems, Inc.  Nine Eighteen Freeburg Ave.   Belleville, IL  62222-0529

HOW TO ORDER REPAIR PARTS

PARTS LIST

Содержание DV-25-2SG

Страница 1: ...onvertible for use with other gases unless a certi ed kit is used Installer Leave these instructions with the consumer Consumer Retain these instructions for future use Donotstoreorusegasolineorother...

Страница 2: ...ations 6 Gas Supply 7 Clearances 8 Installation Instructions 8 10 Thermostat Location 10 Lighting Instructions 11 Pilot Flame Characteristics 12 Main Burner Flame Characteristics 12 Maintenance 13 Tro...

Страница 3: ...n More frequent cleaning may be required due to excessive lint from carpeting bedding materials etc It is imperative that control compartments burners and circulating air passageways of the appliance...

Страница 4: ...s perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on w...

Страница 5: ...iredinaccordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certi ed 3 SIGNAGE Ametalorplasticidenti cationplateshallbe permanently mounted to the exterior...

Страница 6: ...ed so it is not subject to physical damage by a moving vehicle Quali ed Installing Agency Installationandreplacementofgaspiping gasutilizationequipment or accessories and repair and servicing of equip...

Страница 7: ...o aid in servicing It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet This should consist of a vertical length of pipe tee connected into the gas line that i...

Страница 8: ...gulator malfunction the six 6 1 83m feet distance will reduce the chance of gas entering the vent cap Location of Furnace Pickalocationonanoutsidewallwithaclearspaceof28 711mm high by 49 124cm wide in...

Страница 9: ...cap into the 4 102mm diameter ueoutlettube Attachventcaptooutside mounting plate with 3 10 x 1 2 13mm screws provided 4 Installation is completed Reassembly And Resealing Vent Air Intake System When...

Страница 10: ...due to spiders System Check Figure 6 Amillivoltmeterisrequiredtocheckthesystem Millivoltreadings should be Across the thermopile terminals 400 450 millivolts with thermostat OFF Across the thermopile...

Страница 11: ...clockwise to OFF Do not force 5 Replace casing front assembly 1 STOP Read the safety information above 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance if appli ca...

Страница 12: ...ng on the inner casing bottom On Propane gas if a whistling noise resonation occurs screw air adjustment bolt into the chamber support in order to reduce the amount of primary air If the whistling noi...

Страница 13: ...s a See Page 12 Primary Air Adjustment b Reduce manifold pressure c Size main burner ori ce with a drill bit For DV 25 use 54 drill bit For DV 35 use 50 drill bit Removing Main Burner 1 Disconnect the...

Страница 14: ...ifold 30 R 191 Manifold Union Assembly 31 R 5600 Gas Valve Nat 7000 MVRLC 31 R 5601 Gas Valve LP 7000 MVRLC 32 DV 1003 Valve Bracket 33 DV 764 Gasket Chamber Support DV 765 2 Each Required 34 DV 908 V...

Страница 15: ...12434 7 0706 Page 15 PARTS VIEW...

Страница 16: ...l from black hot wire on motor 4 Attach green ground wire beneath one of the 10 x 1 2 13mm screws on the blower housing Fan Control The automatic fan control is located in the switch box The switch bo...

Страница 17: ...ng 2 or 3 drops each time If the motor fails to start and hums it could be a tight bearing due to lack of oil This may be corrected by pouring kerosene in the oil holes allowing to stand for a few hou...

Страница 18: ...12434 7 0706 Page 18 SERVICE NOTES...

Страница 19: ...12434 7 0706 Page 19 SERVICE NOTES...

Страница 20: ...12434 7 0706 Page 20 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com...

Отзывы: