The gas line can be routed either through the floor  or wall.  The gas 

line opening should be made at this time.  Location of the opening 

will be determined by the position of floor joists and the valve and 

union used for servicing.

Gas supply 

Check all local codes for requirements, especially for the size and 

type of gas supply line required.

NOTICE

:

 Never use plastic pipe. Check to confirm whether your 

local codes allow copper tubing or galvanized.

NOTICE

:

 Since some municipalities have additional local codes, it is 

always best to consult your local authority and installation code.

Figure 1

Installing a New main Gas cock 

Each appliance should have its own manual gas cock.
A manual main gas cock should be located in the vicinity of the unit.  

Where none exists, or where its size or location is not adequate, 

contact your local authorized installer for installation or relocation.
Compounds used on threaded joints of gas piping shall be resistant 

to the action of liquefied petroleum gases.  The gas lines must be 

checked for leaks by the installer.  This should be done with a soap 

solution watching for bubbles on all exposed connections,  and if 

unexposed, a pressure test should be made. 

never use an exposed flame to check for leaks.  Appliance 

must be disconnected from piping at inlet of control valve  and 

pipe capped or plugged for pressure test.  Never pressure test 

with appliance connected; control valve will sustain damage!

A gas valve and ground joint union should be installed in the gas 

line upstream of the gas control to aid in servicing.  It is required 

by the National Fuel gas Code that a drip line be installed near 

the gas inlet.  This should consist of a vertical length of pipe tee 

connected into the gas line that is capped on the bottom in which 

condensation and foreign particles may collect.

figure 2

Method of Installing a Tee Fitting Sediment Trap (Figure 2)

The use of the following gas connectors is recommended:

—  ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing 

and Fittings

—  ANS Z21.45 Assembled Flexible Appliance Connectors of Other 

Than All-Metal Construction

The above connectors may be used if acceptable by the authority 

having jurisdiction. The state of Massachusetts requires that a flex

-

ible appliance connector cannot exceed three feet in length.

Pressure testing of the Gas supply system

1.  To check the inlet pressure to the gas valve, a 1/8" (3mm) N.P.T. 

plugged tapping, accessible for test gauge connection, must be 

placed immediately upstream of the gas supply connection to 

the appliance.

2.  The appliance and its appliance main gas valve must be discon-

nected from the gas supply piping system during any pressure 

testing of that system at test pressures in excess of 1/2 psig (3.5 

kPa).

3.   The appliance must be isolated from the gas supply piping sys-

tem by closing its equipment shutoff valve during any pressure 

testing of the gas supply piping system at test pressures equal 

to or less than 1/2 psig (3.5 kPa).

Attention!

  If one of the above procedures results in pressures in 

excess of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve, 

it will result in a hazardous condition.

checking manifold Pressure

Natural gas will have a manifold pressure of approximately 3.5" w.c. 

(.87kPa)  at the pressure regulator outlet with the inlet pressure 

to the pressure regulator from a minimum of 5.0" w.c. (1.245kPa) 

for the purpose of input adjustment to a maximum of 10.5" w.c. 

(2.615kPa).   Propane/LP gas  will have a manifold pressure ap

-

proximately 10.0" w.c. (2.49kPa) at the pressure regulator outlet 

with the inlet pressure to the pressure regulator from a minimum 

of 11.0" w.c. (2.739kPa) for the purpose of input adjustment to a 

maximum of 13.0" w.c. (3.237kPa).  

A test gage connection is located downstream of the gas appliance 

pressure regulator for measuring gas pressure.  The connection is 

a 1/8 inch (3mm) N.P.T. plugged tapping.

GAs suPPLy

Recommended Gas Pipe diameter

Pipe Length

Schedule 40 Pipe

Inside Diameter

Tubing, Type L 

Outside Diameter

Nat.

L.P.

Nat.

L.P.

0-10 feet

0-3 meters

1/2”

12.7mm

3/8”

9.5mm

1/2”

12.7mm

3/8”

9.5mm

10-40 feet

4-12 meters

1/2”

12.7mm

1/2”

12.7mm

5/8”

15.9mm

1/2”

12.7mm

40-100 feet

13-30 meters

1/2”

12.7mm

1/2”

12.7mm

3/4”

19mm

1/2”

12.7mm

100-150 feet

31-46 meters

3/4”

19mm

1/2”

12.7mm

7/8”

22.2mm

3/4”

19mm

VIEW FROM TOP OF HEATER

1 11/16” (43mm)

TO WALL

3 9/16”

(90mm)

GAS INLET IN BOTTOM
OF HEATER

Содержание BF-10-3

Страница 1: ...located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with ot...

Страница 2: ...nd Ventilation Air 6 Gas Supply 7 Clearances 8 Optional Floor Stand Installation 8 Wall Mount Installation 9 Lighting Instructions 10 Main Burner Flame Characteristics 11 Pilot Flame Characteristics 1...

Страница 3: ...ree from combustible materials gasoline and other flammable vapors and liquids Warning Any change to this HEATER or its controlS can be dangerous Any safety screen or guard removed for servicing an ap...

Страница 4: ...ights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption...

Страница 5: ...nstaller must have owner fill out and mail warranty card supplied with unvented room heater 3 Installer should show owner how to start and operate unvented room heater Always consult your local Buildi...

Страница 6: ...rea in which the BF 20 may be located and for determining if this area fits the definition of an unconfined space The input of the BF 20 is 20 000 Btu per hour Based on the 50 cubic feet per 1 000 Btu...

Страница 7: ...Than All Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a flex ible appliance connector cannot exceed...

Страница 8: ...and meets requirement The base referred to in this section does not mean the fire proof base as used on wood stoves The protection is for rugs that are extremely thick and light colored tile Figure 5...

Страница 9: ...20 1 8 511mm 2 51mm 2 51mm 22 559mm BF 30 Figure 7 BF 10 and BF 20 Figure 6 Refer to Figures 6 and 7 for measurements in order to locate 4 mounting holes on wall Figures 6 and 7 are the front views of...

Страница 10: ...when the safety magnet in the gas control is de energized Pilot can now be relighted Repeat steps 4 through 8 10 Turn gas control knob counterclockwise to HI 11 Turn on all electric power to applianc...

Страница 11: ...in burner is factory set at a 3 32 opening If yellow flames occur on main burner loosen 1 4 screw on air shutter in order to increase air shutter opening The slot on air shutter allows the air opening...

Страница 12: ...ulb which is located at the casing assembly bottom adjusts the main burner flame between minimum input and maximum input BF 30 The gas control modulates from a minimum input of 8 500 Btu HR 2 5 KW H L...

Страница 13: ...ore lower louver is replaced onto casing assembly To Remove Gas Valve From Casing Assembly 1 Turn off gas supply to the heater 2 Turn off electrical supply to the heater if optional blower SRB 18T or...

Страница 14: ...ompletely depressed or held in long enough b INTERLOCK latching device is operative see Lighting Instructions Page 10 Step 9 c Thermocouple lead not tightened into gas control tighten thermocouple lea...

Страница 15: ...AS VALVE 19 R 6563 GAS VALVE NAT LPG 20 SR 113 VALVE BRACKET 21 10460 BURNER BRACKET LEFT 22 10422 BURNER BF 10 BF 20 22 10481 BURNER BF 30 23 10424 AIR SHUTTER BF 10 ONLY 24 10461 BURNER BRACKET RIGH...

Страница 16: ...35965 0 0615 Page 16 PARTS VIEW...

Страница 17: ...using downward Place the bottom flange of the blower housing over the top edge of the top heat shield Insert the blower housing into the top portion of the heater by pivoting the blower housing upward...

Страница 18: ...lect lint and could require periodic cleaning If the air output decreases or the noise level increases it indicates a dirty blower wheel To clean blower wheel 1 Turn OFF gas supply to the heater 2 Tur...

Страница 19: ...eater Hearth and Grills Victor Division of F W Webb Company 200 Locust Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwweb...

Страница 20: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: