TO TURN OFF gAS TO APPLIANCE

1.   STOP!   Read the safety information above.

2.  Set thermostat (gas control knob) to lowest setting.
3.  Turn off all electric power to the appliance (if applicable).

4.   Push in gas control knob slightly and turn clockwise 

 

 to "OFF".  Do not force.

 

5.   Wait ten (10) minutes   to clear out any gas.  Then smell for 

gas, including near the floor.  If you smell gas, STOP! Follow 

"B" in the safety information above.  If you don't smell gas, 

go to the next step.

6.   Find pilot - the pilot is attached at the 

bottom of the burner assembly .

7.   Turn gas control knob counterclock-

wise 

 to "PILOT."

8.   Push in gas control knob all the way 

and hold in.  Repeatedly push the 

piezo ignitor button until pilot is lit (or 

use a match to light pilot).  Continue to hold the control knob 

in for about one (1) minute after the pilot is lit.  Release knob 

and it will pop back up.  Pilot should remain lit.  If it goes out, 

repeat steps 4 through 8.

• 

If knob does not pop up when released, stop and im

-

mediately call your service technician or gas supplier.  

• 

If the pilot will not stay lit after several tries, turn the gas 

control knob to "OFF" and call your service technician or 

gas supplier.  

 9.  Attention!  gas control has an INTERLOCK latching device.  

When the pilot is initially lit and the safety magnet is energized 

(pilot stays "ON") the INTERLOCK latching device becomes 

operative.  If the gas control is turned to the "OFF" position 

or gas flow to the appliance is shut off, the pilot cannot be 

relighted until the safety magnet is de-energized (approximately 

60 seconds).  There will be an audible "click" when the safety 

magnet in the gas control is de-energized.  Pilot can now be 

relighted.  Repeat steps 4 through 8.

10.  Turn gas control knob counterclockwise  

 

 

to "hI". 

11.  Turn on all electric power to appliance (if applicable).
12.  Set thermostat (gas control knob) to desired setting from "HI" 

to "LO".

FOR yOUR SAFETy READ BEFORE LIghTINg

WARNINg:

  If you do not follow these instructions exactly, a fire or explosion may 

result causing property damage, personal injury or loss of life.

A.   This appliance has a pilot which must be lighted by 

hand.  When lighting the pilot, follow these instructions 

exactly.

B.   BEFORE LIghTINg  smell all around the appliance area 

for gas.  Be sure to smell next to the floor because some 

gas is heavier than air and will settle on the floor.

 

WhAT TO DO IF yOU SMELL gAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; 

 

do not use any phone in your building.

•  Immediately call your gas supplier from a neighbor's 

phone.  Follow the gas supplier's instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

C.   Use only your hand to push in or turn the gas control 

knob.  Never use tools.  If the knob will not push in or 

turn by hand, don't try to repair it; call  a  qualified service 

technician.  Force or attempted repair may result in a 

fire or explosion.

D.   Do not use this appliance if any part has been under 

water.  Immediately call a qualified service technician 

to inspect the appliance and to replace any part of the 

control system and any gas control which has been 

under water.

1.   Set thermostat (gas control knob) to lowest setting.

2.   Turn off all electric power to appliance if service is to 

be performed (if applicable).

3.   Push in gas control knob slightly and turn clock-

wise  

 to "OFF".  Do not force.

LIghTINg INSTRUCTIONS

LIGHtING INstRuctIoNs

Содержание BF-10-3

Страница 1: ...located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with ot...

Страница 2: ...nd Ventilation Air 6 Gas Supply 7 Clearances 8 Optional Floor Stand Installation 8 Wall Mount Installation 9 Lighting Instructions 10 Main Burner Flame Characteristics 11 Pilot Flame Characteristics 1...

Страница 3: ...ree from combustible materials gasoline and other flammable vapors and liquids Warning Any change to this HEATER or its controlS can be dangerous Any safety screen or guard removed for servicing an ap...

Страница 4: ...ights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption...

Страница 5: ...nstaller must have owner fill out and mail warranty card supplied with unvented room heater 3 Installer should show owner how to start and operate unvented room heater Always consult your local Buildi...

Страница 6: ...rea in which the BF 20 may be located and for determining if this area fits the definition of an unconfined space The input of the BF 20 is 20 000 Btu per hour Based on the 50 cubic feet per 1 000 Btu...

Страница 7: ...Than All Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a flex ible appliance connector cannot exceed...

Страница 8: ...and meets requirement The base referred to in this section does not mean the fire proof base as used on wood stoves The protection is for rugs that are extremely thick and light colored tile Figure 5...

Страница 9: ...20 1 8 511mm 2 51mm 2 51mm 22 559mm BF 30 Figure 7 BF 10 and BF 20 Figure 6 Refer to Figures 6 and 7 for measurements in order to locate 4 mounting holes on wall Figures 6 and 7 are the front views of...

Страница 10: ...when the safety magnet in the gas control is de energized Pilot can now be relighted Repeat steps 4 through 8 10 Turn gas control knob counterclockwise to HI 11 Turn on all electric power to applianc...

Страница 11: ...in burner is factory set at a 3 32 opening If yellow flames occur on main burner loosen 1 4 screw on air shutter in order to increase air shutter opening The slot on air shutter allows the air opening...

Страница 12: ...ulb which is located at the casing assembly bottom adjusts the main burner flame between minimum input and maximum input BF 30 The gas control modulates from a minimum input of 8 500 Btu HR 2 5 KW H L...

Страница 13: ...ore lower louver is replaced onto casing assembly To Remove Gas Valve From Casing Assembly 1 Turn off gas supply to the heater 2 Turn off electrical supply to the heater if optional blower SRB 18T or...

Страница 14: ...ompletely depressed or held in long enough b INTERLOCK latching device is operative see Lighting Instructions Page 10 Step 9 c Thermocouple lead not tightened into gas control tighten thermocouple lea...

Страница 15: ...AS VALVE 19 R 6563 GAS VALVE NAT LPG 20 SR 113 VALVE BRACKET 21 10460 BURNER BRACKET LEFT 22 10422 BURNER BF 10 BF 20 22 10481 BURNER BF 30 23 10424 AIR SHUTTER BF 10 ONLY 24 10461 BURNER BRACKET RIGH...

Страница 16: ...35965 0 0615 Page 16 PARTS VIEW...

Страница 17: ...using downward Place the bottom flange of the blower housing over the top edge of the top heat shield Insert the blower housing into the top portion of the heater by pivoting the blower housing upward...

Страница 18: ...lect lint and could require periodic cleaning If the air output decreases or the noise level increases it indicates a dirty blower wheel To clean blower wheel 1 Turn OFF gas supply to the heater 2 Tur...

Страница 19: ...eater Hearth and Grills Victor Division of F W Webb Company 200 Locust Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwweb...

Страница 20: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: