background image

25231-0-0109

Page 17

PaRTS LiST

INDex

NO.

pArT NuMber

DeScrIpTION

vfp32fb2DL

vfp32fb2eL

vfp32fb2cL

vfp32fb2Df

vfp32fb2ef

vfp32fb2cf

1

17247

17247

17247

17247

17247

17247

ToP STanDoFF

2

17169

17169

17169

n/a

n/a

n/a

UPPER LoUVER

3

10554

10554

10554

10554

10554

10554

FRaMing BRaCKET

4

17170

17170

17170

n/a

n/a

n/a

LoWER LoUVER

5

17162

17162

17162

17162

17162

17162

JUnCTion BoX aSSEMBLY

6

R3492

R3492

R3492

R3492

R3492

R3492

Receptacle

7

R3491

R3491

R3491

R3491

R3491

R3491

CoVER, JUnCTion BoX

8

19945

19945

20448

19945

19945

20448

BRaCKET, ToP BRiCK RETainER 

9

19401

19401

19401

19401

19401

19401

BRaCKET, BoTToM BRiCK 

RETainER 

10

R8666

R9419

R8226

R8666

R9419

R8226

BRiCK PanEL RigHT

11

BRiCK PanEL BaCK

12

BRiCK PanEL LEFT

13

20020

20020

20020

20020

20020

20020

HooD

14

R7051

R7051

R7051

R7051

R7051

R7051

RoD, SCREEn

15

R8212

R8212

R8212

R8212

R8212

R8212

SCREEn CURTain

16

R8727

R8727

R8727

R8727

R8727

R8727

HoLE PLUg 

17

19990

19990

19990

19990

19990

19990

BLoWER CoVER PLaTE

18

R9292

R9292

-

R9292

R9292

-

HEaRTH LEDgE, RigHT

19

R9293

R9293

-

R9293

R9293

-

HEaRTH LEDgE, LEFT

20

R9294

R9294

-

R9294

R9294

-

HEaRTH LEDgE, CEnTER

21

23004

23004

-

23004

23004

-

RETainER, HEaRTH

INDex 

NO.

pArT NuMber

DeScrIpTION

vfp36fb2DL

vfp36fb2eL

vfp36fb2cL

vfp36fb2Df

vfp36fb2ef

vfp36fb2cf

1

17247

17247

17247

17247

17247

17247

ToP STanDoFF

2

18807

18807

18807

n/a

n/a

n/a

UPPER LoUVER

3

10554

10554

10554

10554

10554

10554

FRaMing BRaCKET

4

18808

18808

18808

n/a

n/a

n/a

LoWER LoUVER

5

17162

17162

17162

17162

17162

17162

JUnCTion BoX aSSEMBLY

6

R3492

R3492

R3492

R3492

R3492

R3492

Receptacle

7

R3491

R3491

R3491

R3491

R3491

R3491

CoVER, JUnCTion BoX

8

19945

19945

20448

19945

19945

20448

BRaCKET, ToP BRiCK RETainER 

9

19401

19401

19401

19401

19401

19401

BRaCKET, BoTToM BRiCK 

RETainER 

10

R8669

R9420

R8228

R8669

R9420

R8228

BRiCK PanEL RigHT

11

BRiCK PanEL BaCK

12

BRiCK PanEL LEFT

13

20145

20145

20145

20145

20145

20145

HooD

14

R7052

R7052

R7052

R7052

R7052

R7052

RoD, SCREEn

15

R8201

R8201

R8201

R8201

R8201

R8201

SCREEn CURTain

16

R8727

R8727

R8727

R8727

R8727

R8727

HoLE PLUg 

17

19990

19990

19990

19990

19990

19990

BLoWER CoVER PLaTE

18

R9292

R9292

-

R9292

R9292

-

HEaRTH LEDgE, RigHT

19

R9293

R9293

-

R9293

R9293

-

HEaRTH LEDgE, LEFT

20

R9295

R9295

-

R9295

R9295

-

HEaRTH LEDgE, CEnTER

21

23004

23004

-

23004

23004

-

RETainER, HEaRTH

Содержание VFP32FB2CF-2

Страница 1: ...or assistance or additional in formation consult a qualified installer service agency or the gas supplier Carefully review the instructions supplied with the decora tive type unvented room heater for...

Страница 2: ...talling Hood 8 9 Gas Line Connection 9 Optional Fresh Air Kit Installation Instructions 10 12 Optional Single Speed Blower Installations Instructions 13 15 Junction Box Wiring Installation Instruction...

Страница 3: ...such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is operating I...

Страница 4: ...finishing materials may extend to the top standoff screws on the front edge of the outer wrap See Figures 2a 2b CLEARANCES 45 6 3 MAX PERPENDICULAR SIDE WALL FRONT FACE SIDE FIREBOX TOP VIEW COMBUSTI...

Страница 5: ...irebox is 2 Leave at least 36 clearance from the front of the firebox MANTEL STANDARD HOOD 13 10 12 MAX 42 MIN CEILING TO TOP OF HOOD 11 1 2 MIN FIREBOX FACE 84 MIN CEILING TO FLOOR CEILING COMBUSTIBL...

Страница 6: ...or other combustible material other than wood flooring it should be installed on a metal or wood panel extending the full width and depth of the unit At this point you should have decided what compon...

Страница 7: ...39 1 2 43 1 2 34 1 2 39 1 2 43 1 2 C 21 7 16 21 7 16 21 7 16 21 7 16 21 7 16 21 7 16 D 27 1 4 32 1 4 36 1 4 27 1 4 32 1 4 36 1 4 E 38 1 2 38 1 2 38 1 2 38 1 2 38 1 2 38 1 2 F 31 36 40 31 36 40 G 27 13...

Страница 8: ...desired they can be purchased as an option Attachment is the same as the standard black hood Flush Face Models 1 On flush face models loosen the two screws A holding firebox top to face panel then sli...

Страница 9: ...TALL Contact your dealer for proper model Always use an external regulator for all LP fireboxes to reduce the supply tank pressure to a maximum of 14 w c This is in addition to the regulator fitted to...

Страница 10: ...uce outside air to the fireplace or firebox as desired It must be installed prior to or at the time of fireplace or firebox installation to framing The FreshAir kit must be installed prior to the inst...

Страница 11: ...LY OUTER CASING FRESH AIR ROD OUTSIDE AIR ROD BRACKET Figure 20 OUTSIDE AIR ROD BRACKET OPEN FRESH AIR ROD CONTROL LEVER LEFT SIDE VIEW OF FIREBOX OPENING TOP CUTAWAY VIEW DAMPER ASSEMBLY OUTER CASING...

Страница 12: ...clamps or screws 3 Run the other end of the duct through the exterior wall cut out 4 From the outside of the building connect the duct to the collar on the outside air vent assembly with band clamp or...

Страница 13: ...f the FBB5 Blower assembly It is recommended that installation of the wiring be performed by a qualified electrician See Figure 25 1 If installed turn OFF gas supply to firebox gas log 2 If applicable...

Страница 14: ...minal Attach this terminal to the open terminal on the blower power cord See Figure 32 Connection B 10 Route the wires away from moving parts of the blower as sembly and retain wires together near the...

Страница 15: ...a dirty blower wheel Remove fan and clean blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control k...

Страница 16: ...box Install a ULlisted cable clamp not supplied in the knockout hole Leave approximately 6 of wire in the junction box for connection Attach black wire to one side of the receptacle and white wire to...

Страница 17: ...3 R9293 HEARTH LEDGE LEFT 20 R9294 R9294 R9294 R9294 HEARTH LEDGE CENTER 21 23004 23004 23004 23004 RETAINER HEARTH INDEX NO PART NUMBER DESCRIPTION VFP36FB2DL VFP36FB2EL VFP36FB2CL VFP36FB2DF VFP36FB...

Страница 18: ...42FB2DL VFP42FB2EL VFP42FB2CL VFP42FB2DF VFP42FB2EF VFP42FB2CF 1 17247 17247 17247 17247 17247 17247 TOP STANDOFF 2 17187 17187 17187 N A N A N A UPPER LOUVER 3 10554 10554 10554 10554 10554 10554 FRA...

Страница 19: ...25231 0 0109 Page 19 PARTS VIEW 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 16 17 17 21 19 20 18...

Страница 20: ...Air Kit 1 2 8 4 7 6 5 3 Deluxe and Premium Fireboxes BVA 1 Frame Kits Standard 3 Piece Frame Kits Black Brass Stainless Steel or Hammered Pewter Extruded Aluminum Frame Kits Black Brass Stainless Stee...

Страница 21: ...s Steel finishes Contact dealer for all available optional louver accessories Bottom Trim Strip Available as optional kits in Black Brass Hammered Pew ter and Stainless Steel finishes Contact dealer f...

Страница 22: ...25231 0 0109 Page 22 SERVICE NOTES...

Страница 23: ...25231 0 0109 Page 23 SERVICE NOTES...

Страница 24: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: