Figures 28, 30 and 32
show a correct pilot flame pattern. The
correct flame will be blue and will extend beyond the thermocouple.
The flame will surround the thermocouple just below the tip. A slight
yellow flame may occur where the pilot flame and main burner flame
meet.
Figures 29, 31 and 33
show an incorrect pilot flame pattern.
The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the
heater will shut down.
MILLIVOLT PILOT
Correct Pilot Flame Pattern
THERMOPILE
PILOT
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NATURAL)
Figure 28
Incorrect Pilot Flame Pattern
THERMOPILE
PILOT
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NATURAL)
Figure 29
If pilot flame pattern is incorrect, as shown in Figure 29
• See Troubleshooting, page 36.
HYDRAULIC THERMOSTAT PILOT
Correct Pilot Flame Pattern
Figure 30
Incorrect Pilot Flame Pattern
Figure 31
If pilot flame pattern is incorrect, as shown in Figure 31
• See Troubleshooting, page 36.