background image

29516-10-0713

Page 41

To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.

com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the 

nature of the problem with the unit. 

To Order Parts After the Warranty Period, please contact your dealer or one of the Master Parts Distributors listed below. 

This list changes from time to time. For the current list, please click on the Master Parts button at www.empirecomfort.com.

Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered Original 

Equipment repair parts for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems Inc. 

Dey Distributing

1401 Willow Lake Boulevard

Vadnais Heights, MN 55101

phone: 

651-490-9191

Toll Free:

 800-397-1339

Website:

 www.deydistributing.com

parts: Heater, Hearth and Grills

East Coast Energy products

10 East Route 36

West Long Branch, NJ 07764

phone: 

732-870-8809

Toll Free:

 800-755-8809

Fax: 

732-870-8811

Website: 

www.eastcoastenergy.com

parts: Heater, Hearth and Grills

Victor Division of F. W. Webb Company

200 Locust Street

Hartford, CT 06114

phone:

 860-722-2433

Toll Free: 

800-243-9360

Fax: 

860-293-0479

Toll Free Fax:

 800-274-2004

Websites: 

www.fwwebb.com & www.victormfg.com

parts: Heater, Hearth and Grills

MASTER pARTS DISTRIBUTOR LIST

parts Not Under Warranty

Parts can be ordered through your Service Person, Dealer, or a Master Parts Distributor. See this page for the Master Parts Distribu-

tors list.  For best results, the 

service person or dealer

 should order parts through the distributor. Parts can be shipped directly to the 

service person/dealer

.

Warranty parts

Warranty parts will need a proof of purchase and can be ordered by your Service Person or Dealer. Proof of purchase is 

required

 for 

warranty parts.

All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number and Serial Number from the 

name plate on your equipment. Then determine the Part Number (

not

 the Index Number) and the Description of each part from the fol-

lowing illustration and part list. Be sure to give all this information . . .

Appliance Model Number  

      Part Description 

Appliance Serial Number 

 

Part Number  

Type of Gas (Propane or Natural) 

Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. 

Shipments contingent upon strikes, fires and all causes beyond our control.

HOW TO ORDER REpAIR pARTS

Содержание VFLL38FP30L-1

Страница 1: ...life Installer Leave this manual with the appliance Consumer Retain this manual for future reference EMPIRE EMPIRE Comfort Systems This appliance may be installed in an aftermarket permanently located...

Страница 2: ...15 DECORATIVE ACCESSORY INSTALLATION 16 17 MILLIVOLT CONTROL VALVE LIGHTING INSTRUCTIONS 18 IP LIGHTING INSTRUCTIONS 19 PILOT FLAME CHARACTERISTICS 20 21 OPERATION INSTRUCTIONS FLAME APPEARANCE 22 CLE...

Страница 3: ...to high temperatures the appliance should be located out of traffic and away from furniture and draperies Children and adults should be alerted to the hazard of high surface temperature and should st...

Страница 4: ...erform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wall...

Страница 5: ...ent free appliance If the air blows directly into the flame causing it to disrupt the flame it should be turned off or redirected Ceiling fans could be reversed to possibly eliminate flame impingement...

Страница 6: ...orifice size Well Head Gas Installations Some natural gas utilities use well head gas This may affect the Btuoutputoftheunit Contactthegascompanyfortheheatingvalue Contact the manufacturer or your gas...

Страница 7: ...Part Number Description DF38EHPBL Decorative Front Eastgate Black and Pewter DF38WHP Decorative Front Tidewater Pewter DF38WBL Decorative Front Tidewater Black LK5 120 V Lighting Kit Requires Switch...

Страница 8: ...the fireplace The standoffs are shipped in a flat state on top of the fireplace 1 Locate the two steel standoffs on top of the fireplace 2 Remove the two screws that secure the standoffs in place sav...

Страница 9: ...13 2 Insert fireplace into enclosure 3 Level firebox 4 Secure six framing brackets with drywall screws to the framed opening above the fireplace as shown in figures 4 6 and 12 These brackets should be...

Страница 10: ...or less with openings gasketed or sealed and b Weather stripping has been added on openable windows and doors and c Caulking or sealants are applied to areas such as joints around window and door fra...

Страница 11: ...BTUH of the total input rating of the gas equipment in the confined space Figure 7 WARNING Rework worksheet adding the space of the adjoining unconfined space The combined spaces must have enough fre...

Страница 12: ...hutoffvalvemustbedisconnected fromsupplypipingsystemduringanypressuretestingofthatsystem at test pressures in excess of 1 2 psig 3 5kPa The appliance must be isolated from the gas supply piping system...

Страница 13: ...mly to re seal Do not over torque Check for gas leaks Checking Manifold Pressure MILLIVOLT VALVES Natural gas will have a manifold pressure of approximately 3 5 w c for maximum input or 1 6 w c for mi...

Страница 14: ...LAR COMBUSTIBLE SIDE WALL 36 MINIMUM CLEARANCE TO CEILING NON COMBUSTIBLE BOARD REQUIRED IN THIS AREA SUPPLIED WITH FIREPLACE Figure 12 CLEARANCES FINISHED WALL FLAT MANTEL SHELF 2 22 18 4 6 8 10 12 2...

Страница 15: ...The flow of heat can ignite combustibles Do not attach combustible material to the mantel of your fireplace This is a fire hazard Figure 14 No greeting cards stockings or ornamentation of any type sh...

Страница 16: ...CAUTION Never place media materials on or next to the burner The Decorative Glass options are available in various colors and package sizes Choose the size appropriate for your fireplaces See list on...

Страница 17: ...ce of the Top Cover Start by placing the glass along the front edge of the top cover then gradually place the glass around the top until completely covered Do not allow the glass to fall around the bu...

Страница 18: ...l knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF un less knob is pushed in slightly Do not force 6 Wait ten 10 minutes to clear out any gas Then smell for gas inc...

Страница 19: ...o remote instructions for detailed operation information FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these instructions exactly a fire or explosion may result causing property da...

Страница 20: ...le to cool When the thermocouple cools the heater will shut down THERMOPILE PILOT THERMOCOUPLE LPG THERMOCOUPLE NATURAL Correct Pilot Flame Pattern for MILLIVOLT Figure 27 THERMOPILE PILOT THERMOCOUPL...

Страница 21: ...m the pilot tubing When this procedure is required grasp nut A with an open end wrench 2 Blow air pressure through the holes indicated by the arrows This will blow out foreign materials such as dust l...

Страница 22: ...ing by your dealer or qualified service technician is recommended to prevent malfunction and or sooting TURN OFF HEATER AND ALLOW TO COOL BEFORE CLEANING Remove any optional decorative covers or decor...

Страница 23: ...ng the appliance the remote receiver must be placed to the left of the gas valve Refer to remote control installation and operating instructions for more details on remote control Figure 33 H N REMOTE...

Страница 24: ...ransmitter This is part of the system s design If the signal light does not illuminate check the position of the transmitter s battery REMOTE RECEIVER Figure 35 The remote receiver operates on 4 AA si...

Страница 25: ...es not included be used to make connections between the terminal wiring block on the millivolt gas valve or electronic module and the wire terminals on the remote receiver For the best results use 18...

Страница 26: ...iver signals between the remote receiver and the gas valve Recommended length is no longer than 20 feet The transmitter should operate with as little as 5 0 volts battery power TROUBLE SHOOTING If you...

Страница 27: ...ol knob not pressed in while in PILOT position Press in control knob while in PILOT position d Airingaslineswheninstalled Continueholdingdowncontrol knob Repeat igniting operation until air is removed...

Страница 28: ...NTENANCE OF THE RECEIVER PLACE THE RECEIVER S 3 POSITION SLIDER SWITCH IN THE OFF POSITION DURING INSTALLATION OR MAINTENANCE TURN OFF MAIN GAS SUPPLY TO THE APPLIANCE PRIOR TO REMOVING OR REINSERTING...

Страница 29: ...hild safety lock out Room Temperature Set Point Temperature Level State Flame ON Thermostat OFF ON SMART Transmission Figure 39 Transmitter LCD display RECEIVER The Proflame Receiver Figure 40a and 40...

Страница 30: ...articular code of that Transmitter The system is now initialized Temperature indication Display With the system in the OFF position press the Thermostat Key and the Mode Key at the same time Look at t...

Страница 31: ...he Down Arrow Key once will reduce the flame height by one step un til the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed wh...

Страница 32: ...ure is displayed on the LCD screen of the Transmitter SET TEMPERATURE ROOM TEMPERATURE Figure 48a Figure 48b Smart Thermostat Transmitter Operation The Smart Thermostat function adjusts the flame heig...

Страница 33: ...on will disappear Figure 52 Receiver The life span of the Receiver batteries depends on various factors quality of the batteries used the number of ignitions of the appli ance the number of changes to...

Страница 34: ...manual and on labels found in the control compartment located in the lower cavity of the appliance 2 During the operating season or in power outage periods it is recommended that the pilot remain in t...

Страница 35: ...CAUTION Do not operate the appliance with panel s removed cracked or broken Replacement of the panel s should be done by a licensed or qualified service person WARNING Improper installation adjustment...

Страница 36: ...ge 19 and Wiring Diagram on page 35 Troubleshooting Before proceeding with the procedures in the following trouble shooting table verify that the power supply AC DC adapter is present and that the bat...

Страница 37: ...4 Replace the DFC board 1 Verify the electrical connections integrity and make sure they are in accordance with the relevant system wiring diagram If necessary replace the wire harness 2 If pilot flow...

Страница 38: ...voltage at ignition between the EV1 terminal and the ground connection on the valve body 5 1 If the voltage is greater than 0 then Replace Valve 5 2 Or Replace DFC 6 Check the pressure at the outlet p...

Страница 39: ...ing detail refer to Figure 54 INSTALLATION 120 Volt electrical requirements will depend on which model fireplace is installed For VFLL38FP30L series millivolt operated system Wiring is only needed if...

Страница 40: ...e of the receptacle and the white wire to the opposite side Secure the incoming ground wire under the green ground screw provided on the receptacle Figure 57 Figure 58 5 If only installing the LK5 Acc...

Страница 41: ...ust Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS...

Страница 42: ...Y PILOT LP 15 29464 TUBING ASSEMBLY REGULATOR TO PILOT NAT 17 29463 TUBING ASSEMBLY VALVE TO REGULATOR NAT 18 29466 BURNER BOX FRONT 19 R9761 PIEZO IGNITOR 20 26304 IGNITOR BRACKET 21 29462 CENTER SUP...

Страница 43: ...29516 10 0713 Page 43 EXPLODED VIEW 23 28 26 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 16 14 15 16 17 13 9 22 24 24 25 29 25 30 2 19 18 20 21...

Страница 44: ...ote control thermostat accessory or other part fail because of defective workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The...

Страница 45: ...29516 10 0713 Page 45 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 46: ...29516 10 0713 Page 46 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 47: ...29516 10 0713 Page 47 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 48: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: