34. Install the Termination Back Plate by aligning the large
rectangular hole with the Air Duct. Using (6) # 10 X
1/2" screws, secure the Back Plate to the Air Duct.
See
Figure 36.
Figure 36
35. Secure the Back Plate to the Outer Termination with (8)
# 10 X 1/2" screws.
See Figure 37.
Do not install the
upper and lower side screws at this time.
Figure 37
36. To install the Outer Cover and Screen, place the “U”
shaped screen inside the Outer Cover, then place the
Outer Cover into the Outer Termination frame. Using (4)
# 10 X 1/2" screws, secure the Outer Cover to complete
the installation.
See Figure 38.
BACK PLATE
OUTER TERMINATION ASSEMBLY
SCREEN
COVER PLATE
Figure 38
FINISHING
The Outer Termination Assembly is designed to allow
exterior combustible finishing materials to be installed
around the outer edges of the termination. This provides
for J-channel, or other siding materials to be installed up
to the termination face. It is the installer(s) responsibility
to caulk or seal around the termination to prevent water
leakage to the building envelope.
BEFORE FINISHING INTERIOR WALL
After all components are in place and electrical and gas
connections have been made, test run the fireplace to make
sure that all heat management accessories are operating
properly. Listen for resonance or rattles in the flex-vent
ductwork, and add strapping to prevent movement if
necessary. The flex-vent run and system wiring are not
easily servicable after the interior wall is finished.
NOTE:
When finishing interior wall, leave the Limit Switch
connected to the Wire Harness to prevent wires from
falling back inside the wall. Use Limit Switch Plate as a
guide to mark holes and attach to wall with wall anchors
suitable for chosen finishing material (not included).
OUTER
TERMINATION
ASSEMBLY
BACK PLATE
SCREEN
COVER
PLATE