Notice  (Damper clamp Installation)

When installing your gas appliance as a vented installation 

the damper clamp must be used.

When installing your gas appliance as a vent-free installation 

the damper clamp can be used to eliminate the potential for 

odors when burning the logs for the first time.

Installing Damper clamp (Figure 9) 

Remove all ashes or other debris from the fireplace. If the 

fireplace is equipped with an ash dump be sure to seal the 

door with furnace cement or high temperature silicone. Be 

sure to check the damper for proper operation and verify that 

the flue passageway is open.

Place the clamp over the lip of the damper and tighten the 

hold down bolt until the clamp is securely attached to the 

damper.  This  will  prevent  the  damper  from  accidentally 

closing. 
The gas appliance may be installed as a vented decorative 

gas appliance in compliance with ANSI Z21.60 and National 

Fuel Gas Code. When the gas appliance is operated with 

the damper open, non-combustible material and minimum 

mantel requirements do not apply.

Figure 9

INSTALLING AS A VeNTeD APPLIANce

DAMPER

DAMPER

TYPICAL FIREPLACE

DAMPER CLAMP

FOr MASONry BuILT FIrePLAceS

Free OPeNING AreA OF cHIMNey DAMPer FOr VeNTING 

cOMBuSTION PrODucTS FrOM DecOrATIVe APPLIANceS 

FOr INSTALLATION IN SOLID FueL BurNING FIrePLAceS

Height is from hearth to top of chimney and the minimum height 

is 6 feet.

**  Chart shows minimum opening (sq. in.) for given height and 

input rate.

• 

Turn off gas supply to fireplace or firebox.

• 

Have the fireplace floor and chimney professionally cleaned to 

remove ashes, soot, creosote or other obstructions.

 

Have this cleaning performed annually after installation.

• 

Seal any fresh air vents or ash clean-out doors located on floor 

or wall of fireplace. If not, drafting may cause pilot outage or 

sooting. Use a heat-resistant sealant. Do not seal chimney flue 

damper.

Install and operate the appliance as directed in this manual.

FOr FAcTOry BuILT FIrePLAceS 

Free OPeNING AreA OF cHIMNey DAMPer FOr VeNTING 

cOMBuSTION PrODucTS FrOM DecOrATIVe APPLIANceS 

FOr INSTALLATION IN SOLID FueL BurNING FIrePLAceS

*  Height is from hearth to top of chimney and the minimum 

height is 10 feet.

**  Chart shows minimum opening (sq. in.) for given height and 

input rate.

Appliance Input rate (BTu/hr)

20

30

40

Chimney 

Height* (ft)

Minimum Opening** (sq. in.)

10

11.3

16.6

22.1

15

8.6

12.6

17.3

20

7.5

10.8

14.5

25

6.6

9.6

12.6

30

6.2

9.1

11.3

35

5.7

8.0

10.8

40

5.3

7.5

10.2

Appliance Input rate (BTu/hr)

20

30

40

Chimney 

Height* (ft)

Minimum Opening** (sq. in.)

6

17.6

25.7

33.8

8

16.5

23.7

31.2

10

15.1

21.7

28.7

15

14.1

19.9

26.1

20

12.9

18.5

23.7

30

12.2

16.9

21.6

FIrePLAce PrePArATION

Содержание VFIL Series

Страница 1: ...per hour Refer to page 8 Installer Leave this manual with the appliance Consumer Retain this manual for future reference This appliance may be installed in an aftermarket permanently located manufactu...

Страница 2: ...ppliance 15 16 Gas Supply 17 Operation Instructions Flame Appearance 18 Wiring VFRL Models 19 VFRL 18 24 30 Lighting Instructions 20 VFRL1810 N P Lighting Instructions 21 VFIL Series Operating Instruc...

Страница 3: ...soft click then release the button To ADJUST the Flame Height 1 Press and hold the upper right button for a higher flame 2 Press and hold the lower right button for a lower flame Note If you hold the...

Страница 4: ...26532 5 0311 Page 4 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 5: ...y allow operation of this appliance in a vented configuration Check your state or local codes Correct installation of burner proper location of the heater and annual cleaning are necessary to avoid po...

Страница 6: ...erform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on wall...

Страница 7: ...pose of resale from the manufacturer This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Solid fuelsshallnotbeb...

Страница 8: ...tuseanunventedroomheaterastheprimaryheatsource an entire house WATER VAPOR A BY PRODUCT OF UNVENTED ROOM HEATERS Model Gas Valve Type Regulator Pressure Setting Gas Inlet Pressure Max Gas Inlet Pressu...

Страница 9: ...ollowing Gas burner assembly Two 2 masonry anchoring screws two 2 10 x 1 2 black sheet metal anchoring screws and damper clamp The millivolt controlled heater may be operated with optional devices for...

Страница 10: ...for use with the appliance 6 Also refer to IMPORTANT SAFETY INFORMATION on page 5 of this manual WARNING DO NOT OPERATE THIS GAS APPLIANCE WITH GLASS DOORS CLOSED Clothing or other flammable material...

Страница 11: ...the ceiling and the other must be within 12 inches of the floor The required sizing of these openings is determined by whether inside or outside air is used to support combustion the method by which...

Страница 12: ...ional fireplace hood If you cannot extend non combustible material at least 8 you must operate heater with flue damper open Minimum Dimensions For Solid Fuel Burning Fireplaces UL127 Factory Built Fir...

Страница 13: ...to one of the following steps Operate the heater with the flue damper open See page 14 for Installing as a Vented Appliance Raise the mantel to the proper height Remove the mantel Floor Clearance Figu...

Страница 14: ...mbustion products from decorativeappliances for installation in solid fuel burning fireplaces Height is from hearth to top of chimney and the minimum height is 6 feet Chart shows minimum opening sq in...

Страница 15: ...burner without the Support Legs installed the remote receiver box must be installed outside of the firebox away from excessive heat However the remote receiver may be placed under the elevated Loft B...

Страница 16: ...nside the front edge of the fireplace or firebox opening 4 Anchor holes are provided in the bottom base or optional support legs of the burner housing After centering the burner base correctly mark th...

Страница 17: ...pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect Figure 13 The use of the following gas connectors is recommended ANS Z21 24 Ap...

Страница 18: ...e possibly causing headaches or eye or lung irritation This is a normal and temporary occurrence The initial break in operation should last 2 3 hours with the burner at the highest setting Provide max...

Страница 19: ...hermocouple produces millivolts electrical current which energizes the magnet in the gas valve After 30 seconds to 1 minute time period you can release the gas control knob and the pilot will stay ON...

Страница 20: ...ch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed...

Страница 21: ...MOTE OFF ON switch to OFF 3 Turn off all electric power to the appliance if applicable 4 Open bottom louver assembly if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Kn...

Страница 22: ...he hand held remote The remote control and receiver should be programmed to gether from the factory All settings for time and temperature control must be set up by the user as desired Installation of...

Страница 23: ...y not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired opera tion Changes or modifications not expressly approved by t...

Страница 24: ...F 12 HOUR CLOCK Display Timer Thermostat RF Remote Handsets Press OFF and small flame until display changes from Fahrenheit 12 hour clock to Celsius 24 hour clock and vice versa AUTOMATIC OPERATION W...

Страница 25: ...e area around the appliance including near the floor If you detect gas STOP Follow A in the safety information on page 27 If no gas is present proceed to step 6 6 Place ON OFF switch in ON position SE...

Страница 26: ...Replace appliance top cover MISCELLANEOUS Low Battery Indication Receiver three short beeps will sound when motor turns Remote with display BATT will appear on display NOTE Thermostatic Displays Hands...

Страница 27: ...u smell gas STOP FOLLOW B in the safety information above If you don t smell gas go to the next step LIGHTING PROCEDURE HANDSET METHOD 1 Turn control arrow on valve face to ON Press the I O but ton to...

Страница 28: ...on RESET Battery Compartment Ignition Cable Thermocouple RF Antenna Thermo Current Cable 1 Thermo Current Cable 2 or ON OFF Switch with Soldered Cable ON OFF Switch 8 Wire Cable Interrupter Block Comb...

Страница 29: ...cause the thermocouple to cool When the thermocouple cools the heater will shut down Correct Pilot Flame Pattern for VFRL Figure 23 Correct Pilot Flame Pattern for VFIL Figure 24 Incorrect Pilot Flame...

Страница 30: ...ram for location of items discussed below Inspect and clean burner air intake hole Remove lint or particles with vacuum or brush Failure to keep air intake hole clean will result in sooting and poor c...

Страница 31: ...ntrol knob not pressed in while in PILOT position Press in control knob while in PILOT position d Air in gas lines when installed Continue holding down control knob Repeat igniting operation until air...

Страница 32: ...ddition of the Decorative Top Cover accessory should be performed after the Loft burner has been fully installed se cured and tested for leaks If operating the burner with a Re mote Control make sure...

Страница 33: ...operates with the remote correctly 2 Before applying the glass to the burner top attach the black silicone U channel edges located in the Instruction Enve lope to each side of the Top Cover See Figur...

Страница 34: ...Y 8 R2423 R2423 R2423 MALE CONNECTOR 9 26653 26653 26653 VALVE SUPPORT PLATE 10 27463 R10563 R10563 VALVE LP 10 27462 R10562 R10562 VALVE NAT 11 R5170 R5170 R5170 PILOT ASSEMBLY LP 11 R5171 R5171 R517...

Страница 35: ...26532 5 0311 Page 35 VFIL PARTS VIEW 16 17 17 3 4 5 6 7 8 9 10 13 11 12 14 15 2 1 18 19 17 17 SET OFF TEMP PM 20...

Страница 36: ...9 R9028 R9028 R9028 R9028 ON OFF EXTENSION KNOB 10 R9369 R3625 R3625 R3625 VALVE LP 10 R9368 R3626 R3626 R3626 VALVE NAT 11 R3623 R3623 R3623 R3623 PILOT ASSEMBLY LPG 11 R3624 R3624 R3624 R3624 PILOT...

Страница 37: ...26532 5 0311 Page 37 3 4 5 6 7 8 9 10 12 11 13 14 15 17 18 19 16 2 1 20 VFRL PARTS VIEW...

Страница 38: ...reet Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS DISTR...

Страница 39: ...26532 5 0311 Page 39 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 40: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: