Locating Firebox
Place firebox in framing opening. Use the four (4) framing brackets
provided on the firebox to attach firebox to framing. Different hole
locations can be used for finishing materials with thicknesses of
3/8", 1/2" and 3/4". attach these materials with screws provided,
two (2) per framing bracket.
See Figure 8.
Framing brackets should fit directly against framing material. Use
at least one (1) nail per bracket to secure in place.
Check squareness of the firebox prior to securing to framed opening.
See Figure 9.
Figure 8
A black hood that is furnished with each firebox (or optional hood)
MUST be installed before the firebox is used. Failure to do so
may create a possible fire hazard. The hood is located behind
upper louver, or inside the firebox on flush face units. If brass,
stainless steel, or hammered pewter hoods are desired, they can
be purchased as an option. attachment is the same as the standard
black hood.
Flush Face Models
1. On flush face models, loosen the two screws (A) holding firebox
top to face panel, then slide the hood flange between the firebox
top and face panel and re-tighten the screws.
2. install one (1) screw at each end of the hood as shown (c).
Louvered Models
1. if you have a louvered model, remove upper louver.
2. Place the top hood flange on top of the firebox, then install three
screws through the firebox top from below and screw into the
pilot holes in the hood flange (B).
3. install one (1) screw at each end of the hood as shown (c).
4. Re-install louver.
Caution:
the hood must be installed prior to operation of appliance.
See Figure 10
Flush Face Models
Figure 10
FIREBOX OPENING
CHECK TO SEE
THAT BOX IS SQUARE
PRIOR TO ATTACHING TO
FRAMING
Figure 9
FIREBOX INSTALLATION INSTRUCTIONS (continued)
INSTALLING hOOD
B
C
INNER FIREBOX TOP
Louvered Models
ATTACH (4)
FRAMING BRACKETS
TO SIDES OF FIREBOX
PRIOR TO INSTALLING
UNIT TO FRAMED OPENING
A
C
A
C