background image

Page 17

20248-2-0806

Label all wires prior to disconnection when servicing controls. 

Wiring errors can cause improper and dangerous operation. Verify 

proper operation after servicing.
Millivolt thermopile is self powered, gas valve does not require 110 

volts. Maximum length of 20 feet of 16 AWG to conductor wires 

is to be used with all optional switches.
Use the two leads (Brown and Black/Red wires) to attach optional 

components.

Check 750 Millivolt System Operation

Millivolt system and all individual components may be checked 

with a millivolt meter 0-1000 MV range.

Remote Receiver

Use the following steps to place the remote receiver adjacent to 

the gas valve.

Attention: 

The  remote  receiver  bracket  is  not  used  in  this 

installation.
1.  The remote receiver 

can not

 be placed behind the gas valve 

and burner assembly.

2.  When facing the appliance, the remote receiver must be placed 

to the 

right

 of the gas valve and burner assembly.

Note:

  Do  not  let  remote  control  receiver  come  in  contact  with 

burner assembly.
On circulating vent-free firebox, install remote control receiver 

behind bottom louver.
Refer to remote control installation and operating instructions for 

more details on remote control.

VF24FP3-1 Wiring Diagram

 

Figure 20

WIRING

Содержание VF24FP2-1

Страница 1: ...s of gas input per hour Refer to page 6 WARNING If not installed operated and main tained in accordance with the manufacturer s in structions this product could expose you to sub stances in fuel or fr...

Страница 2: ...Placement 12 Placement of Glowing Embers Rock Wool 12 Operation Instructions Flame Appearance 12 VF24FP3 1 Lighting Instructions 13 VF24FP2 1 Lighting Instructions 14 Pilot Flame Characteristics 15 16...

Страница 3: ...azard of high surface temperature and should stay away to avoid burns or clothing ignition Young childrenshould becarefullysupervisedwhen they are in the same room with the appliance Do not place clot...

Страница 4: ...ight pilot lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or...

Страница 5: ...your gas company before changing spud ori ce size WARNING Failure to keep the primary air opening s of the burner s clean may result in sooting and property damage Instructions to Installer 1 Installe...

Страница 6: ...s water vapor retarder with a rating of one perm or less with openings gasketed or sealed and b Weatherstripping has been added on openable windows and doors and c Caulking or sealants are applied to...

Страница 7: ...ount of BTU Hr used BTU Hr maximum the space can support BTU Hr actual amount of BTU Hr used Example 25 600 BTU Hr maximum the space can support 38 000 BTU Hr actual amount of BTU Hr used Warning If t...

Страница 8: ...nectors of Other Than All Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a exible appliance connector c...

Страница 9: ...place opening to any combustible wall or material should not be less than 4 inches 2 Clearances from the top of the replace opening to the ceiling should not be less than 30 inches Mantel Clearances f...

Страница 10: ...g ange will secure the replace 6 Placeleftmantelsideagainstbase Insertdowelsinbreastboard into left mantel side 7 Use four 4 pre drilled screw holes on back of breastboard to secure breastboard to man...

Страница 11: ...the appliance the gas supply will enter on right hand side See Gas Supply Page 8 3 Insert replace into enclosure 4 Attach nailing anges to framing with a screw or nail 5 Finishedwallsurfacewillbe ush...

Страница 12: ...ttle is necessary to cover this area Excess ember material causes the yellow ame to become orange and stringy Apply just enough to obtain slow glow and a gold yellow ame Avoid any drafts that alter bu...

Страница 13: ...Turn ON OFF switch to OFF position and or set thermostat if present to lowest setting If applicable Turn off all electric power to the heater 1 STOP Read the safety information label 2 Make sure the m...

Страница 14: ...FF GAS TO APPLIANCE 1 Set thermostat gas control knob to lowest setting 2 Turn off all electric power to appliance if service is to be performed if applicable LIGHTING INSTRUCTIONS 7 Turn gas control...

Страница 15: ...re 15 If pilot ame pattern is incorrect as shown in Figure 14 See Troubleshooting page 18 Cleaning and Maintenance Pilot Oxygen Depletion Sensor Pilot When the pilot has a large yellow tip ame clean t...

Страница 16: ...8 Remove air shutter from ori ce tting 9 ForNaturalgasonly remove20 000BTUmainburnerori ce marked 49 from ori ce tting and replace with 10 000 BTU VF24FP3 1 Main Burner Operation The gas control modul...

Страница 17: ...be checked with a millivolt meter 0 1000 MV range Remote Receiver Use the following steps to place the remote receiver adjacent to the gas valve Attention The remote receiver bracket is not used in t...

Страница 18: ...rrect Replace gas regula tor 7 ODS pilot lights but ame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pressed in long enough...

Страница 19: ...ITCH WIRE HARNESS NOT SHOWN P 263 NIPPLE 8 NOT SHOWN 15465 TUBING VALVE TO PILOT REGULATOR NAT NOT SHOWN 15466 TUBING PILOT REGULATOR TO PILOT NAT NOT SHOWN R 7063 PILOT REGULATOR NAT VF24FP2 1 ONLY 1...

Страница 20: ...Page 20 20248 2 0806 PARTS VIEW 10 27 26 25 VF24FP2 28 VF24FP3 31 29 32 30 1 7 2 4 5 6 8 9 10 11 12 13 25 26 27 28 29 30 31 32 24 3 14 15 16 17 18 19 23 20 21 22...

Страница 21: ...box 5 Place the 2 liner mounting brackets over the front edges of the 2 side brick liners Attach liner mounting brackets to outer casing with 4 four 10 x 1 2 screws from Step 4 6 Replacelogsintoburner...

Страница 22: ...motor Align and attach blower assembly to outer casing side See Figure 2 10 Snap Heyco into blower shield side 11 Placeblowershieldsideadjacenttomotor Routeblowermotor wires through Heyco on blower s...

Страница 23: ...d on left front of valve cover on burner assembly Insert blower shield front adjacent to blower motor and blower shield side Align clearance hole on blower shield front with left front screw hole on v...

Страница 24: ...screws at interior top of inner casing that were loosened in Step 6 30 Attach burner assembly to inner bottom with three 3 10 x 1 2 screws from Step 5 31 Attach rear log support to inner casing with t...

Страница 25: ...the ground the appliance cord plug can be plugged into the adapter and be electrically grounded CAUTION Labelallwirespriortodisconnectionwhenservic ing controls Wiring errors can cause improper and d...

Страница 26: ...part number and description coincide 1 2 3 Index Number Part Number Description VPF24BR Brass Trim Kit 1 11328 Trim Top 2 11326 Trim Left 3 11327 Trim Right VPF24SS Stainless Steel Trim Kit 1 20227 Tr...

Страница 27: ...Page 27 20248 2 0806 SERVICE NOTES...

Страница 28: ...Page 28 20248 2 0806 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com...

Отзывы: