background image

Page 12

20248-2-0806

Provided with the log set is a small bag of glowing embers (rock 

wool) to be placed between logs on the flat metal surface of the 

burner.
Placement of the embers (rock wool) is very individual and light 

coverage of the areas indicated will provide your best effects. We 

recommend separation of the rock wool by hand and make your 

coverage as light and fluffy as possible.
Place just enough embers (rock wool) on the burner to obtain the 

glow and a gold yellow flame.
Do not place rock wool over large ports in rear portion of burner.
A  thin  layer  of  rock  wool  should  be  placed  under  open  space 

between the right and left middle logs.
Rock  wool  should 

not

  be  placed  in  the  area  of  the  pilot 

assembly.

Replacement of loose material (glowing embers) must be purchased 

from Empire Comfort Systems, Inc. Application of excess loose 

material (glowing embers) may adversely affect performance of 

the heater. 
WARNING: All previously applied loose material must be removed 

prior to reapplication.
Refer to Parts List, Page 19 to order loose material (rock wool).

Replacement Loose Material (glowing embers) Part Number

AVF24

15998

Platinum Bright Embers

PE-20-1

Note: A single layer of embers is to be used when applying Platinum 

Bright Embers (alone or in combination with production embers) 

to the burner.

Flames from the pilot (rear right back side of the pan burner) as 

well as the main flame should be visually checked as the log set 

is installed.
In normal operation at full rate after 10 to 15 minutes, the flame 

appearance should be sets of yellow flames.

NOTE:

 all flames will be random by design, flame height will go 

up and down.
Glowing embers (rock wool) can cover the pan burner in between 

the front and middle logs, but very little is necessary to cover this 

area. Excess ember material causes the yellow flame to become 

orange and stringy. Apply just enough to obtain slow glow and a 

gold, yellow flame.
Avoid any drafts that alter burner flame patterns. Do not allow fans 

to blow directly into fireplace. Do not place a blower inside the 

burner area of the firebox. Ceiling fans may create drafts that alter 

flame patterns. Sooting and improper burning will result.

During  manufacturing,  fabricating  and  shipping,  various 

components of this appliance are treated with certain oils, films or 

bonding agents. These chemicals are not harmful, but may produce 

annoying smoke and smells as they are burned off during the initial 

operation of the appliance, possibly causing headaches or eye or 

lung irritation. This is a normal and temporary occurrence.
The initial break-in operation should last 2-3 hours with the burner 

at the highest setting. Provide maximum ventilation by opening 

windows or doors to allow odors to dissipate. Any odors remaining 

after this initial break-in will be slight and will disappear with 

continued use.
This appliance must not be used with glass doors in the closed 

position. This can lead to pilot outages and severe sooting outside 

the fireplace.

PLACEMENT OF GLOWING EMBERS (ROCK WOOL)

OPERATION INSTRUCTIONS/FLAME APPEARANCE

LOG PLACEMENT

1.  Place rear (#1) log onto two (2) pins on rear log support.

2.  Place left, front (#2) log onto two (2) left, front pins on burner 

pan.

3.  Place  right,  front  (#3)  log  onto  two  (2)  right,  front  pins  on 

burner pan.

4.  Place branch (#4) log onto two (2) pins on rear (#1) log.

Attention:

 Do not use Figure 13 to order logs. Refer to Page 19, 

Parts list and Page 20, Parts View to order logs.

Refer to Figure 13 for the following warning.

Warning: 

Failure  to  position  the  parts  in  accordance  with 

this diagram or failure to use only parts specifically approved 

with this heater may result in property damage or personal 

injury.

Figure 13

Содержание VF24FP2-1

Страница 1: ...s of gas input per hour Refer to page 6 WARNING If not installed operated and main tained in accordance with the manufacturer s in structions this product could expose you to sub stances in fuel or fr...

Страница 2: ...Placement 12 Placement of Glowing Embers Rock Wool 12 Operation Instructions Flame Appearance 12 VF24FP3 1 Lighting Instructions 13 VF24FP2 1 Lighting Instructions 14 Pilot Flame Characteristics 15 16...

Страница 3: ...azard of high surface temperature and should stay away to avoid burns or clothing ignition Young childrenshould becarefullysupervisedwhen they are in the same room with the appliance Do not place clot...

Страница 4: ...ight pilot lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or...

Страница 5: ...your gas company before changing spud ori ce size WARNING Failure to keep the primary air opening s of the burner s clean may result in sooting and property damage Instructions to Installer 1 Installe...

Страница 6: ...s water vapor retarder with a rating of one perm or less with openings gasketed or sealed and b Weatherstripping has been added on openable windows and doors and c Caulking or sealants are applied to...

Страница 7: ...ount of BTU Hr used BTU Hr maximum the space can support BTU Hr actual amount of BTU Hr used Example 25 600 BTU Hr maximum the space can support 38 000 BTU Hr actual amount of BTU Hr used Warning If t...

Страница 8: ...nectors of Other Than All Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a exible appliance connector c...

Страница 9: ...place opening to any combustible wall or material should not be less than 4 inches 2 Clearances from the top of the replace opening to the ceiling should not be less than 30 inches Mantel Clearances f...

Страница 10: ...g ange will secure the replace 6 Placeleftmantelsideagainstbase Insertdowelsinbreastboard into left mantel side 7 Use four 4 pre drilled screw holes on back of breastboard to secure breastboard to man...

Страница 11: ...the appliance the gas supply will enter on right hand side See Gas Supply Page 8 3 Insert replace into enclosure 4 Attach nailing anges to framing with a screw or nail 5 Finishedwallsurfacewillbe ush...

Страница 12: ...ttle is necessary to cover this area Excess ember material causes the yellow ame to become orange and stringy Apply just enough to obtain slow glow and a gold yellow ame Avoid any drafts that alter bu...

Страница 13: ...Turn ON OFF switch to OFF position and or set thermostat if present to lowest setting If applicable Turn off all electric power to the heater 1 STOP Read the safety information label 2 Make sure the m...

Страница 14: ...FF GAS TO APPLIANCE 1 Set thermostat gas control knob to lowest setting 2 Turn off all electric power to appliance if service is to be performed if applicable LIGHTING INSTRUCTIONS 7 Turn gas control...

Страница 15: ...re 15 If pilot ame pattern is incorrect as shown in Figure 14 See Troubleshooting page 18 Cleaning and Maintenance Pilot Oxygen Depletion Sensor Pilot When the pilot has a large yellow tip ame clean t...

Страница 16: ...8 Remove air shutter from ori ce tting 9 ForNaturalgasonly remove20 000BTUmainburnerori ce marked 49 from ori ce tting and replace with 10 000 BTU VF24FP3 1 Main Burner Operation The gas control modul...

Страница 17: ...be checked with a millivolt meter 0 1000 MV range Remote Receiver Use the following steps to place the remote receiver adjacent to the gas valve Attention The remote receiver bracket is not used in t...

Страница 18: ...rrect Replace gas regula tor 7 ODS pilot lights but ame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pressed in long enough...

Страница 19: ...ITCH WIRE HARNESS NOT SHOWN P 263 NIPPLE 8 NOT SHOWN 15465 TUBING VALVE TO PILOT REGULATOR NAT NOT SHOWN 15466 TUBING PILOT REGULATOR TO PILOT NAT NOT SHOWN R 7063 PILOT REGULATOR NAT VF24FP2 1 ONLY 1...

Страница 20: ...Page 20 20248 2 0806 PARTS VIEW 10 27 26 25 VF24FP2 28 VF24FP3 31 29 32 30 1 7 2 4 5 6 8 9 10 11 12 13 25 26 27 28 29 30 31 32 24 3 14 15 16 17 18 19 23 20 21 22...

Страница 21: ...box 5 Place the 2 liner mounting brackets over the front edges of the 2 side brick liners Attach liner mounting brackets to outer casing with 4 four 10 x 1 2 screws from Step 4 6 Replacelogsintoburner...

Страница 22: ...motor Align and attach blower assembly to outer casing side See Figure 2 10 Snap Heyco into blower shield side 11 Placeblowershieldsideadjacenttomotor Routeblowermotor wires through Heyco on blower s...

Страница 23: ...d on left front of valve cover on burner assembly Insert blower shield front adjacent to blower motor and blower shield side Align clearance hole on blower shield front with left front screw hole on v...

Страница 24: ...screws at interior top of inner casing that were loosened in Step 6 30 Attach burner assembly to inner bottom with three 3 10 x 1 2 screws from Step 5 31 Attach rear log support to inner casing with t...

Страница 25: ...the ground the appliance cord plug can be plugged into the adapter and be electrically grounded CAUTION Labelallwirespriortodisconnectionwhenservic ing controls Wiring errors can cause improper and d...

Страница 26: ...part number and description coincide 1 2 3 Index Number Part Number Description VPF24BR Brass Trim Kit 1 11328 Trim Top 2 11326 Trim Left 3 11327 Trim Right VPF24SS Stainless Steel Trim Kit 1 20227 Tr...

Страница 27: ...Page 27 20248 2 0806 SERVICE NOTES...

Страница 28: ...Page 28 20248 2 0806 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com...

Отзывы: