SpECIFICATIONS & ACCESSOREIS

Venting Kits

Description

Contents

DVKI2P

Vertical Vent Kit 17 1/2’

One piece of 35’ FlexVent (split for 17 1/2’ vent run), Round Cap, Flashing, connectors, 

and clamps.  

Recommended when installing to an existing round fireplace chimney pipe.

DVVK3FV

Vertical Vent Kit 25’

Two pieces of 25’ FlexVent, Rectangle Cap, Flashing, connectors, and clamps

Recommended when installing to a square or rectangular clay flue.

DVK35

Vent Extension Kit

35’ flex vent extension section with 2 connectors and 4 clamps

NOTICE

When installing vent caps, special locally made flashings may be required to properly seal the vent system to the existing 

chimney termination.

DXT30IN

Lp

NAT

Input Btu/hr (Maximum)

30,000

30,000

Input Btu/hr (Minimum)

24,000

21,000

KWH (Maximum)

8.79

8.79

KWH (Minimum)

7.03

6.15

Orifice

1.65mm

#36

Air Shutter Opening

FULL OPEN

1/4” OPEN

DXT35IN

Lp

NAT

Input Btu/hr (Maximum)

35,000

35,000

Input Btu/hr (Minimum)

28,000

24,000

KWH (Maximum)

10.26

10.26

KWH (Minimum)

8.35

7.03

Orifice

#50

#33

Air Shutter Opening

FULL OPEN

1/8” OPEN

DECORATIVE FRONTS

Model

Description

Used On

DF30ABL

“Accord” - Black

DXT30IN

DF30AHP

“Accord” - Hammered Pewter

DXT30IN

DF30ASS

“Accord” - Stainless Steel

DXT30IN

DF30DHPBL “Dunes” - Hammered Pewter and 

Black

DXT30IN

DF30DSSBL “Dunes” - Stainless Steel and Black DXT30IN
DF30VBL

“Veranda” - Black

DXT30IN

DF30VHP

“Veranda” - Hammered Pewter

DXT30IN

DF30VSS

“Veranda” - Stainless Steel

DXT30IN

DF30YBL

“Lafayette” - Black

DXT30IN

DF30YHP

“Lafayette” - Hammered Pewter

DXT30IN

DF30YSS

“Lafayette” - Stainless Steel

DXT30IN

DF35ABL

“Accord” - Black

DXT35IN

DF35AHP

“Accord” - Hammered Pewter

DXT35IN

DF35ASS

“Accord” - Stainless Steel

DXT35IN

DF35DHPBL “Dunes” - Hammered Pewter and 

Black

DXT35IN

DF35DSSBL “Dunes” - Stainless Steel and Black DXT35IN
DF35VBL

“Veranda” - Black

DXT35IN

DF35VHP

“Veranda” - Hammered Pewter

DXT35IN

DF35VSS

“Veranda” - Stainless Steel

DXT35IN

DF35YBL

“Lafayette” - Black

DXT35IN

DF35YHP

“Lafayette” - Hammered Pewter

DXT35IN

DF35YSS

“Lafayette” - Stainless Steel

DXT35IN

FIREpLACE SCREENS

Model

Description

Used On

DVFS30SBL Matte Black

DXT30

DVFS35SBL Matte Black

DXT35

REFLECTIVE LINERS

Model

Description

Used On

DVP30KR

Black, 30-Inch

DXT30

DVP35KR

Black, 35-Inch

DXT35

SURROUNDS

Model

Description

Used On

DS3066BL

3-Sided, 1 Piece, Matte Black

DXT30

DS3566BL

3-Sided, 1 Piece, Matte Black

DXT35

CERAMIC FIBER LINERS

Model

Description

Used On

DVP30XAE

Aged Banded Brick

DXT30

DVP30XNE

Natural Banded Brick

DXT30

DVP30XN

New England Stack

DXT30

DVP30XS

Mountain Stack

DXT30

DVP30XWA

Aged Weave Brick

DXT30

DVP30XWT

Traditional Weave Brick

DXT30

DVP35XAE

Aged Banded Brick, 35-Inch

DXT35

DVP35XNE

Natural Banded Brick, 35-Inch

DXT35

DVP35XN

New England Stack, 35-Inch

DXT35

DVP35XS

Mountain Stack, 35-Inch

DXT35

DVP35XWA

Aged Weave Brick

DXT35

DVP35XWT

Traditional Weave Brick

DXT35

Содержание TRADITIONAL DXT30IN NAT

Страница 1: ...or from fuel combustion which can cause death or serious illness Fireplace Insert Installer Leave this manual with the appliance Consumer Retain this manual for future reference WARNING If the informa...

Страница 2: ...Description Quantity Supplied 1 Latch Tool 1 2 Product Registration Card 1 3 Label Plate 1 4 Warning Label 1 5 1 4 20 Bolt 1 6 Leveling Leg 4 7 AA Battery 2 8 AAA Battery 4 9 Rock Wool 1 See pages 42...

Страница 3: ...BLY PLACEMENT 16 FIBER LINER PLACEMENT 17 REFLECTIVE LINER PLACEMENT 18 19 LOG IDENTIFICATION 20 LOG PLACEMENT 21 28 SAFETY SCREEN BARRIER SURROUND AND DECORATIVE FRONT INSTALLATION 29 LIGHTING INSTRU...

Страница 4: ...nd draperies The glass front or any part removed for servicing the appliance must be replaced prior to operating the appliance Work should be done by a qualified service person Keep burner and control...

Страница 5: ...as can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clos...

Страница 6: ...with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural Gas and Propane Installation Code or CSA B149 1 in Canada Available from theAmerican National Standards Institute Inc 11 West 42nd St New Yo...

Страница 7: ...and Black DXT30IN DF30VBL Veranda Black DXT30IN DF30VHP Veranda Hammered Pewter DXT30IN DF30VSS Veranda Stainless Steel DXT30IN DF30YBL Lafayette Black DXT30IN DF30YHP Lafayette Hammered Pewter DXT30...

Страница 8: ...irements Proper opening size of fireplace required for installation of the fireplace insert INSERT DIMENSIONS in inches DIMENSION DXT30IN DXT35IN A 20 1 8 24 1 16 B 29 3 8 33 3 8 C 18 5 8 21 3 4 D 15...

Страница 9: ...C B G H I J CEILING 76 Distance from Face of Fireplace dimensions in inches Height Above Top of Insert dimensions in inches A 10 F 14 B 8 G 17 1 2 C 6 H 21 1 2 D 3 I 24 1 4 E 1 2 J 27 The minimum dis...

Страница 10: ...ize or location is not adequate contact your local authorized installer for installation or relocation Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied pet...

Страница 11: ...e the exposed grille area should be left open NOTICE Surround panel kits have been tested and approved to cover existing air circulation vents or grilles NOTICE Cutting of sheet metal parts of a firep...

Страница 12: ...o a zero clearance factory built wood burning fireplace the use of the DVKI Round Vertical Termination Kit should allow you to mount the vent adaptor and cap to the exposed round chimney pipe easily C...

Страница 13: ...31210 1 0713 Page 13 VENTING AND INSTALLATION Figure 9...

Страница 14: ...ets forming in the flex venting and subsequently dripping out at joints or seams Condensate can cause corrosion of caps pipe and fittings It may be caused by having excessive lateral runs or having ex...

Страница 15: ...assembly 5 Repeat steps 1 through 3 for the left glass clip CAUTION Top glass clips are tightly sprung If the Latch tool slips off of the clip while pulling injury may occur Ensure that the latch tool...

Страница 16: ...up until it engages to the glass assembly 5 Repeat steps 2 through 4 for the left glass clip CAUTION Top glass clips are tightly sprung If the Latch tool slips off of the clip while pulling injury ma...

Страница 17: ...ight liner with a retainer bracket by screwing the bracket to the ceiling of the Insert with one 10 x 1 2 screw Figure 19 3 Slide the left liner into the firebox Secure the left liner with a retainer...

Страница 18: ...igure 21 Set the burner cover aside If a reflective burner cover is to be used discard the burner cover that has been removed Figure 21 Figure 22 2 Place rear liner in back of unit Figure 23 3 Place t...

Страница 19: ...e ceiling of the Insert with one 10 x 1 2 screw Figure 26 5 Slide the left liner into the firebox Secure the left liner with a retainer bracket by screwing the bracket to the ceiling of the Insert wit...

Страница 20: ...Log DXT30 Part No 31212 DXT35 Part No 31219 C Right Log DXT30 Part No 31214 DXT35 Part No 31221 D Log Chunk DXT30 Part No 32008 DXT35 Part No 32009 E Front Left Log DXT30 Part No 31215 DXT35 Part No 3...

Страница 21: ...own One bag of embers is included with the original purchase of the appliance Use only half of the bag approximately 0 4 oz for ember placement and save the rest for use after maintenance Notice Burne...

Страница 22: ...31210 1 0713 Page 22 LOG PLACEMENT 1 Place Rear Log A onto burner pins 1 and 2 See Figure 28 for burner pin identification TOP VIEW DXT30 Shown FRONT VIEW DXT30 Shown...

Страница 23: ...1 0713 Page 23 LOG PLACEMENT 2 Place Left Log B onto the two left pins on A log and angled down to sit outside the grate NOTICE Log should not touch grate tang TOP VIEW DXT30 Shown FRONT VIEW DXT30 S...

Страница 24: ...ace Right Log C onto the two right pins on A log and angled down to sit outside the grate and onto burner pin 4 See Figure 28 for burner pin identification NOTICE Log should not touch grate tang TOP V...

Страница 25: ...31210 1 0713 Page 25 LOG PLACEMENT 4 Place Log Chunk D onto burner pins 3 and 5 See Figure 28 for burner pin identification TOP VIEW DXT30 Shown FRONT VIEW DXT30 Shown...

Страница 26: ...31210 1 0713 Page 26 LOG PLACEMENT 5 Place Right Center Log F onto the two pins on C log and burner pin 6 See Figure 28 for burner pin identification TOP VIEW DXT30 Shown FRONT VIEW DXT30 Shown...

Страница 27: ...31210 1 0713 Page 27 LOG PLACEMENT 6 Place Left Center Log E onto the two pins on B log and burner pin 7 See Figure 28 for burner pin identification TOP VIEW DXT30 Shown FRONT VIEW DXT30 Shown...

Страница 28: ...31210 1 0713 Page 28 LOG PLACEMENT 7 Place Front Log G onto the center pin on A log and against the back of the center grate tang TOP VIEW DXT30 Shown FRONT VIEW DXT30 Shown...

Страница 29: ...the hooks on the fireplace screen over the four pegs two each side on the firebox See Figure 30 2 Secure the screen safety barrier to the firebox with two 10 x 1 2 screws See Figure 30 Figure 30 Insta...

Страница 30: ...e is controlled by a hand held remote control Refer to remote instructions for detailed operation information Lighting Instructions A This appliance has a pilot which must be lighted by hand When ligh...

Страница 31: ...ed mobile home where not prohibited by local codes This appliance is not convertible for use with other gases unless a certified kit is used CAUTION Do not operate the appliance with glass panel remov...

Страница 32: ...rature Ratings 0 50 C 32 122 F Radio Frequency 315 MHz NOTICE THE TRANSMITTER AND RECEIVER ARE RADIO FREQUENCY DEVICES PLACING THE RECEIVER IN OR NEAR METAL SEVERELY REDUCES THE SIGNAL RANGE NOTICE TU...

Страница 33: ...on Display With the system in the OFF position press the THERMOSTAT key and the MODE key at the same time Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of t...

Страница 34: ...sing the DOWN ARROW key once will reduce the flame height by one step until the flame is turned OFF The UP ARROW key will increase the flame height each time it is pressed If the UP ARROW key is press...

Страница 35: ...displayed on the LCD screen of the Transmitter Figure 40 SMART Thermostat Operation The Smart Thermostat function adjusts the flame height in accor dance with the difference between the set point temp...

Страница 36: ...off or adjust fan speed See Figures 32a and 44 A single beep will confirm reception of the command Figure 43 Fan Icon Figure 44 Fan Speed Control Activated Continuous Pilot Intermittent Pilot CPI IPI...

Страница 37: ...the Insert Without a Remote Control Remove the decorative front and outer surround page 29 to ac cess the module With the ON OFF rocker switch in the ON posi tion press with SW1 button on the module...

Страница 38: ...ment on a vacuum cleaner to gently remove dust or soot deposits from logs and burner Glass Cleaning It will be necessary to clean the glass periodically During start up condensation which is normal fo...

Страница 39: ...n access to the rear of the appliance 5 Remove the two screws securing the bottom flange to the firebox See Figure 49 6 Hand bend the flange so that lays flat See Figure 49 7 Remove blower from applia...

Страница 40: ...e the air box and set aside See Figure 53 Figure 53 16 Remove the 18 screws securing the blower access panel to the firebox and set aside Remove the blower access panel and set aside See Figure 54 Fig...

Страница 41: ...31210 1 0713 Page 41 DECORATIVE FRONTS...

Страница 42: ...11 R10423 R10423 PILOT ASSEMBLY NAT 11 R10424 R10424 PILOT ASSEMBLY LPG 12 28917 28917 PILOT SHIELD 13 31195 31196 GLASS FRAME ASSEMBLY 14 28943 28943 AIR BOX 15 28848 28848 BLOWER ACCESS PANEL 16 31...

Страница 43: ...31210 1 0713 Page 43 20 19 21 22 23 24 7 6 8 11 4 3 2 1 13 18 17 16 15 12 14 9 10 5 25 EXPLODED VIEW...

Страница 44: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Страница 45: ...Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be...

Страница 46: ...31210 1 0713 Page 46 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 47: ...31210 1 0713 Page 47 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 48: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: