31210-1-0713
Page 40
BLOWER REMOVAL/REpLACEMENT
14. Slide the burner to the right and lift out.
See Figure 52.
NOTICE:
Sliding the burner to the right ensures that the
orifice disengages from the venturi.
Figure 52
15. Remove the two screws securing the “air box” to the rear of
the firebox. Remove the “air box” and set aside.
See Figure
53.
Figure 53
16. Remove the 18 screws securing the blower access panel to
the firebox and set aside. Remove the blower access panel
and set aside.
See Figure 54.
Figure 54
17. Pull blower far enough through the blower access hole to
disconnect the wires at the connectors.
See Figure 55.
Once
the wires are disconnected, remove blower completely and
discard.
Figure 55
19. Install the replacement blower, and re-install the insert by
reversing the above steps.